Aortic Insufficiency and Hemocompatibility-related Adverse Events in Patients with Left Ventricular Assist Devices

被引:14
|
作者
Imamura, Teruhiko [1 ]
Kim, Gene [1 ]
Nitta, Daisuke [1 ]
Fujino, Takeo [1 ]
Smith, Bryan [1 ]
Kalantari, Sara [1 ]
Ann Nguyen [1 ]
Narang, Nikhil [1 ]
Holzhauser, Luise [1 ]
Grinstein, Jonathan [2 ]
Juricek, Colleen [3 ]
Rodgers, Daniel [1 ]
Song, Tae [3 ]
Ota, Takeyoshi [3 ]
Jeevanandam, Valluvan [3 ]
Sayer, Gabriel [1 ]
Uriel, Nir [1 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, 5841 S Maryland Ave, Chicago, IL 60637 USA
[2] MedStar Heart & Vasc Inst Adv Heart Failure & Car, Div Cardiol, Washington, DC USA
[3] Univ Chicago, Med Ctr, Dept Surg, Chicago, IL 60637 USA
基金
日本学术振兴会;
关键词
Heart failure; hemodynamic; bleeding; SUPPORT; RECOMMENDATIONS; QUANTIFICATION; SEVERITY;
D O I
10.1016/j.cardfail.2019.08.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of Al on HRAE. Methods and Results: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (P = 0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; P = 0.009), due mostly to higher tier I (mild HRAE; P = 0.034) and tier IIIB scores (severe HRAE; P = 0.011). Conclusion: Significant Al, as assessed by Doppler echocardiographic parameters, was associated with HRAE during
引用
收藏
页码:787 / 794
页数:8
相关论文
共 50 条
  • [41] Improved Prognostic Performance of Novel Parameters for Grading Aortic Insufficiency Severity in Patients With Left Ventricular Assist Devices
    Grinstein, Jonathan
    Kruse, Eric
    Sayer, Gabriel
    Fedson, Savitri
    Kim, Gene H.
    Sarswat, Nitasha
    Adatya, Sirtaz
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Mor-Avi, Victor
    Lang, Roberto
    Uriel, Nir
    CIRCULATION, 2015, 132
  • [42] Quantification of Aortic Insufficiency in Patients With Left Ventricular Assist Devices: A Novel Approach Combining Invasive Hemodynamics and Echocardiography
    Grinstein, J.
    Kruse, E.
    Sayer, G.
    Fedson, S.
    Kim, G. H.
    Jorde, U. P.
    Juricek, C.
    Ota, T.
    Jeevanandam, V.
    Lang, R. M.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S154 - S154
  • [43] Hemocompatibility-Related Adverse Events and Survival on Venoarterial Extracorporeal Life Support An ELSO Registry Analysis
    Chung, Mabel
    Cabezas, Fausto R.
    Nunez, Jose I.
    Kennedy, Kevin F.
    Rick, Katelyn
    Rycus, Peter
    Mehra, Mandeep R.
    Garan, A. Reshad
    Kociol, Robb D.
    Grandin, E. Wilson
    JACC-HEART FAILURE, 2020, 8 (11) : 892 - 902
  • [44] Functional Outcomes Not Significantly Impacted by Hemocompatibility-Related Adverse Event Burden among Different Devices
    Pahwa, S.
    Lee, G.
    Tchantchaleishvili, V.
    Weber, M.
    Khullar, V.
    Daly, R.
    Schumer, E.
    Rosenbaum, A.
    Schettle, S.
    Behfar, A.
    Stulak, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S439 - S440
  • [45] The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients
    Cowger, Jennifer
    Pagani, Francis D.
    Haft, Jonathan W.
    Romano, Matthew A.
    Aaronson, Keith D.
    Kolias, Theodore J.
    CIRCULATION-HEART FAILURE, 2010, 3 (06) : 668 - 674
  • [46] Cerebrovascular Events in Patients with Continuous Flow Left Ventricular Assist Devices
    Kim, Y. D.
    Robson, D.
    Macdonald, P. S.
    Spratt, P.
    Jansz, P.
    Hayward, C. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S427 - S427
  • [47] Concomitant repair for mild aortic insufficiency and continuous-flow left ventricular assist devices
    Fukuhara, Shinichi
    Ikegami, Hirohisa
    Polanco, Antonio R.
    Song, Jeremy J.
    Han, Jiho
    Takeda, Koji
    Kurlansky, Paul A.
    Takayama, Hiroo
    Naka, Yoshifumi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (06) : 1062 - 1068
  • [48] Management of aortic insufficiency with continuous flow left ventricular assist devices: Bioprosthetic valve replacement
    Feldman, Chad M.
    Silver, Marc A.
    Sobieski, Michael A.
    Slaughter, Mark S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (12): : 1410 - 1412
  • [49] Impact of Aortic Insufficiency on Unloading Properties of Continuous-Flow Left Ventricular Assist Devices
    Sayer, G.
    Kruse, E.
    Addetia, K.
    Grinstein, J.
    Adatya, S.
    Sarswat, N.
    Kim, G. H.
    Ota, T.
    Jeevanandam, V.
    Lang, R.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S385 - S385
  • [50] Transcatheter Aortic Valve Implantation In Left Ventricular Assist Device Patients With Severe Aortic Insufficiency
    Behbahani-Nejad, Omid
    Mahdavi, Asma
    Nayak, Aditi
    Babaliaros, Vasilis
    Leshnower, Bradley G.
    Greenbaum, Adam
    Byku, Isida
    Perdoncin, Emily
    Jokhadar, Maan
    JOURNAL OF CARDIAC FAILURE, 2023, 29 (04) : 585 - 585