Single center experience with the Sorin Bicarbon prosthesis: A 17-year clinical follow-up

被引:10
作者
Celiento, Michele [1 ]
Filaferro, Luca [1 ]
Milano, Aldo D. [2 ]
Anastasio, Gerardo [1 ]
Ferrari, Gabriele [1 ]
Bortolotti, Uberto [1 ]
机构
[1] Univ Hosp, Sect Cardiac Surg, Pisa, Italy
[2] Univ Verona, Div Cardiac Surg, I-37100 Verona, Italy
关键词
HEART-VALVE PROSTHESIS; HEMODYNAMIC PERFORMANCE; MULTICENTER EXPERIENCE; BILEAFLET VALVE; CARBOMEDICS; COMPLICATIONS; REPLACEMENT; DESIGN;
D O I
10.1016/j.jtcvs.2013.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the long-term results of aortic valve replacement (AVR) and mitral valve replacement (MVR) with the Sorin Bicarbon prosthesis (SBP). Methods: Five hundred seven patients (306 men, 201 women), mean age 62 +/- 10 years (range, 21-86 years), received an SBP between 1994 and 2000; AVR was performed in 344 (67%) and MVR in 163 (33%). The main concomitant procedure was coronary artery grafting in 79 patients (16%). Follow-up was 99% complete; mean follow-up was 12.7 +/- 4.0 years with a cumulative duration of follow-up of 6475 patient-years in the entire group (4348 patient-years for AVR and 2124 patient-years for MVR). Results: Hospital mortality was 2.7% (AVR, 2.03%; MVR, 4.3%). There were 169 late deaths (AVR, 128; MVR, 41). Actuarial survival at 17 years is 49.7% +/- 5.3% for AVR and 62.0% +/- 6.1% for MVR. At the last follow-up, 310 survivors (199 AVR, 111 MVR) are in New York Heart Association functional class I or II. At 17 years, actuarial freedom from valve-related deaths, embolism, and bleeding is 89.8% +/- 4.8%, 85.8% +/- 5.4%, and 96.2% +/- 1.2% after AVR, and 91.9% +/- 3.9%, 96.3% +/- 1.8%, 95.0% +/- 2.9% after MVR. Reoperation was required in 5 patients with AVR (thrombosis in 4 and perivalvular leak in 1). Actuarial freedom from reoperation is 98.1% +/- 0.8% after AVR and 100% after MVR; freedom from endocarditis is 100% after AVR and 99.2% +/- 0.7% after MVR. No cases of intrinsic structural valve failure were observed. Conclusions: The SBP has shown excellent results in terms of clinical improvement and freedom from valve-related complications, even up to 17 years after AVR and MVR. It therefore seems to be a safe option whenever a mechanical prosthesis is needed.
引用
收藏
页码:2039 / 2044
页数:6
相关论文
共 35 条
[1]  
Aagaard J, 2005, J HEART VALVE DIS, V14, P82
[2]   Guidelines for reporting mortality and morbidity after cardiac valve interventions [J].
Akins, Cary W. ;
Miller, D. Craig ;
Turina, Marko I. ;
Kouchoukos, Nicholas T. ;
Blackstone, Eugene H. ;
Grunkemeier, Gary L. ;
Takkenberg, Johanna J. M. ;
David, Tirone E. ;
Butchart, Eric G. ;
Adams, David H. ;
Shahian, David M. ;
Hagl, Siegfried ;
Mayer, John E. ;
Lytle, Bruce W. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04) :732-738
[3]   10 YEARS EXPERIENCE WITH THE ST JUDE MEDICAL VALVE PROSTHESIS [J].
AROM, KV ;
NICOLOFF, DM ;
KERSTEN, TE ;
NORTHRUP, WF ;
LINDSAY, WG ;
EMERY, RW .
ANNALS OF THORACIC SURGERY, 1989, 47 (06) :831-837
[4]   RELATIONSHIP BETWEEN SOME DESIGN CHARACTERISTICS AND WEAR IN THE BICARBON HEART-VALVE PROSTHESIS [J].
ARRU, P ;
RINALDI, S ;
STACCHINO, C ;
VALLANA, F .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (05) :280-293
[5]   The Sorin Bicarbon over 15 years clinical outcomes: multicentre experience in 1704 patients [J].
Azarnoush, Kasra ;
Laborde, Francois ;
de Riberolles, Charles .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :759-766
[6]  
Bayliss Andrew, 2007, Interact Cardiovasc Thorac Surg, V6, P390, DOI 10.1510/icvts.2007.152819
[7]   Sorin Bicarbon™ bileaflet valve:: a 10-year experience [J].
Borman, JB ;
De Riberolles, C .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (01) :86-92
[8]   Bicarbon valve - European multicenter clinical evaluation [J].
Borman, JB ;
Brands, WGB ;
Camilleri, L ;
Cotrufo, M ;
Daenen, W ;
Gandjbakhch, I ;
Infantes, C ;
Khayat, A ;
Laborde, F ;
Pellegrini, A ;
Piwnica, A ;
Reichart, B ;
Sharony, R ;
Walesby, R ;
Warembourg, H .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1998, 13 (06) :685-693
[9]  
Bortolotti U, 2001, J HEART VALVE DIS, V10, P795
[10]   Prospective randomized comparison of CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: Ten-year follow-up [J].
Bryan, Alan J. ;
Rogers, Chris A. ;
Bayliss, Kate ;
Wild, Jan ;
Angelini, Gianni D. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (03) :614-U35