A method for bio-electrical impedance analysis based on a step-voltage response

被引:29
作者
Neves, CEB
Souza, MN
机构
[1] Univ Fed Rio de Janeiro, COPPE, Biomed Engn Program, BR-21945970 Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, Dept Elect EE, BR-21945970 Rio De Janeiro, Brazil
关键词
bioimpedance; step-voltage response; body composition;
D O I
10.1088/0967-3334/21/3/305
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bioimpedance analysis (BIA) has been researched broadly, since it is simple, it presents good results and the analysers are portable, allowing it to be used in field studies. This paper presents a new technique of BIA based on a step-voltage current response and bipolar electrode array. A prototype of this new kind of analyser was developed and constructed to test the technique. Bench tests were performed to calibrate the prototype and the obtained results were comparable to those of commercial analysers. Body composition tests were conducted on 67 subjects of both sexes. Besides the bioimpedance analysis, anthropometric measures, consisting of weight, height, circumference and skinfold thickness, were also obtained from the subjects to allow an estimation of the body composition from anthropometric equations established in the literature. The results point to a good correlation (Pearson coefficient, r = 0.9645) between the anthropometric estimated fat-free mass (FFM) and its analogue estimated by the new bioimpedance technique.
引用
收藏
页码:395 / 408
页数:14
相关论文
共 41 条
[1]  
*AM COLL SPORTS ME, 1995, GUID EX TEST PRESCR
[3]   Sources of error in bioimpedance spectroscopy [J].
Bolton, MP ;
Ward, LC ;
Khan, A ;
Campbell, I ;
Nightingale, P ;
Dewit, O ;
Elia, M .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :235-245
[4]  
Chumlea W. Cameron, 1996, American Journal of Clinical Nutrition, V64, p413S, DOI 10.1093/ajcn/64.3.413S
[5]   Phase angle spectrum analysis and body water [J].
Chumlea, WC ;
Guo, SS ;
Siervogel, RM .
APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) :489-491
[6]  
CHUMLEA WC, 1994, NUTR REV, V52, P123, DOI 10.1111/j.1753-4887.1994.tb01404.x
[7]  
Cornish BH, 1996, EUR J CLIN NUTR, V50, P159
[8]   ALTERATION OF THE EXTRACELLULAR AND TOTAL-BODY WATER VOLUMES MEASURED BY MULTIPLE FREQUENCY BIOELECTRICAL-IMPEDANCE ANALYSIS (MFBIA) [J].
CORNISH, BH ;
WARD, LC ;
THOMAS, BJ .
NUTRITION RESEARCH, 1994, 14 (05) :717-727
[9]   Effect of temperature and sweating on bioimpedance measurements [J].
Cornish, BH ;
Thomas, BJ ;
Ward, LC .
APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) :475-476
[10]   BETWEEN-LABORATORY COMPARISON OF DENSITOMETRY AND BIOELECTRICAL-IMPEDANCE MEASUREMENTS [J].
DEURENBERG, P ;
WESTERTERP, KR ;
WIERIK, EJMV .
BRITISH JOURNAL OF NUTRITION, 1994, 71 (03) :309-316