A Cu/Hg-plated screen-printed electrode (CMSPE) was developed for trace Pb(ll) determination by square-wave anodic stripping voltammetry. The intermetallic property of lead with copper in mercury was utilized to increase the sensitivity of Pb(II) detection. The calculated transfer coefficient value for the Pb(II)/Pb redox process on the CMSPE is similar to 0.5 representing the ideality of the system for Pb(II) detection. Systematic investigations were made to optimize the Cu-Hg plating condition on SPE towards the Pb(II) signals in terms of Cu/Hg ratio, plating potential, and plating time. The optimum conditions for electrochemical and square-wave parameters were also evaluated. The calibration curve was linear in the range of 0-100 ppb Pb(II) with a detection limit of 0.81 ppb (S/N = 3) for 60 s preconcentration time. The analytical utility of the CMPSE was demonstrated by applying to various water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [21] MERCURY-PLATED ROTATING-RING DISK ELECTRODE
    DALY, PJ
    PAGE, DJ
    COMPTON, RG
    ANALYTICAL CHEMISTRY, 1983, 55 (07) : 1191 - 1192
  • [22] Copper Film Modified Glassy Carbon Electrode and Copper Film with Carbon Nanotubes Modified Screen-Printed Electrode for the Cd(II) Determination
    Wasag, Joanna
    Grabarczyk, Malgorzata
    MATERIALS, 2021, 14 (18)
  • [23] Simultaneous detection of copper and lead ions using dithizone modified screen-printed electrode
    Yu, L., 1734, South China University of Technology, Guangzhou, 510640, China (29):
  • [24] Mercury (II) sensor based on nanosilver/chitosan modified screen-printed carbon electrode
    Liu, Ke
    Wang, Qihui
    Zhan, Yifang
    Hong, Shaoli
    Peng, Junjun
    Liu, Huihong
    Mahmud, Sakil
    INORGANIC CHEMISTRY COMMUNICATIONS, 2025, 171
  • [25] Pb(II) Determination in a Single Drop Using a Modified Screen-Printed Electrode
    Zurga, Nika
    Majer, David
    Finsgar, Matjaz
    CHEMOSENSORS, 2021, 9 (02) : 1 - 10
  • [26] Application of screen-printed carbon electrode modified with lead in stripping analysis of Cd(II)
    Tyszczuk-Rotko, Katarzyna
    Domanska, Katarzyna
    Vytras, Karel
    Metelka, Radovan
    Nosal-Wiercinska, Agnieszka
    Sys, Milan
    OPEN CHEMISTRY, 2017, 15 (01): : 28 - 33
  • [27] NOVEL SCREEN-PRINTED GOLD NANO FILM ELECTRODE FOR TRACE MERCURY(II) DETERMINATION USING ANODIC STRIPPING VOLTAMMETRY
    Niu, Xiangheng
    Chen, Chen
    Teng, Yuanjie
    Zhao, Hongli
    Lan, Minbo
    ANALYTICAL LETTERS, 2012, 45 (07) : 764 - 773
  • [28] Resolving the copper interference effect on the stripping chronopotentiometric response of lead(II) obtained at bismuth film screen-printed electrode
    Kadara, RO
    Tothill, LE
    TALANTA, 2005, 66 (05) : 1089 - 1093
  • [29] POLAROGRAPHIC AND MICROCOULOMETRIC DETERMINATIONS WITH A STATIONARY MERCURY-PLATED PLATINUM ELECTRODE
    ROGERS, LB
    MARPLE, TL
    GARDINER, KW
    ANALYTICAL CHEMISTRY, 1953, 25 (03) : 516 - 516
  • [30] Stripping Voltammetric Determination of Mercury in Fish Oil Capsules Using a Screen-printed Gold Electrode
    Squissato, Andre L.
    Rocha, Diego P.
    Almeida, Eduardo S.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2018, 30 (01) : 20 - 23