Strength Analyses of Screws for Femoral Neck Fractures

被引:9
作者
Frydrysek, Karel [1 ]
Sir, Milan [2 ]
Pleva, Leopold [2 ]
机构
[1] VSB Tech Univ Ostrava, Dept Appl Mech, Fac Mech Engn, 17 Listopadu 15-2172, Ostrava 70833, Czech Republic
[2] Univ Hosp Ostrava, Trauma Ctr, 17 Listopadu 1790, Ostrava 70852, Czech Republic
关键词
Biomechanics; Femoral neck fracture; Cancellous screws; Beams on elastic foundation; Strength analyses; Safe factor; ELASTIC-FOUNDATION; CANNULATED SCREWS; KNEE; HEMIARTHROPLASTY; FIXATION; BEAMS; MODEL; BONE; HIP;
D O I
10.1007/s40846-018-0378-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article represents a multidisciplinary approach to biomechanics (engineering + medicine) in the field of "collum femoris" fractures. One possible treatment method for femoral neck fractures, especially for young people, is the application of cancellous (i.e. lag or femoral) screws (with full or cannulated cross-section) made of Ti6Al4V or stainless steel. This paper therefore aims to offer our own numerical model of cancellous screws together with an assessment of them. The new, simple numerical model presented here is derived together with inputs and boundary conditions and is characterized by rapid solution. The model is based on the theory of beams on an elastic foundation and on 2nd order theory (set of three differential 4th order equations, combination of pressure and bending stress-deformation states). It presents the process for calculating displacements, slopes, bending moments, stresses etc. Two examples (i.e. combinations of cancellous screws with full or cannulated cross-section made of stainless steel or Ti6Al4V material) are presented and evaluated (i.e. their displacement, slopes, bending moments, normal forces, shearing forces and stresses). Future developments and other applications are also proposed and mentioned.
引用
收藏
页码:816 / 834
页数:19
相关论文
共 35 条
[1]  
Bartoniek J., 2003, URAZOVA CHIR, V11, P10
[2]   APPLICATION OF BEAMS ON ELASTIC-FOUNDATION AND B-SPLINE SOLUTION METHODOLOGIES TO PARAMETRIC ANALYSIS OF INTRAMEDULLARY IMPLANT SYSTEMS [J].
BECHTOLD, JE ;
RILEY, DR .
JOURNAL OF BIOMECHANICS, 1991, 24 (06) :441-448
[3]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[4]   Hemiarthroplasty compared to internal fixation with percutaneous cannulated screws as treatment of displaced femoral neck fractures in the elderly: cost-utility analysis performed alongside a randomized, controlled trial [J].
Bjornelv, G. M. Waaler ;
Frihagen, F. ;
Madsen, J. E. ;
Nordsletten, L. ;
Aas, E. .
OSTEOPOROSIS INTERNATIONAL, 2012, 23 (06) :1711-1719
[5]   Analysis of Locking Self-Taping Bone Screws for Angularly Stable Plates [J].
Cada, Radek ;
Frydrysek, Karel ;
Sejda, Frantisek ;
Demel, Jiri ;
Pleva, Leopold .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (04) :612-625
[6]  
Filipov O., 2012, INJ SKELETAL BIOMECH, V1, P81
[7]   Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck [J].
Filipov, Orlin .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (07) :539-543
[8]   Experimental evaluation of an elastic foundation model to predict contact pressures in knee replacements [J].
Fregly, BJ ;
Bei, YH ;
Sylvester, ME .
JOURNAL OF BIOMECHANICS, 2003, 36 (11) :1659-1668
[9]   Comparison of re-operation rates following primary and secondary hemiarthroplasty of the hip [J].
Frihagen, Frede ;
Madsen, Jain Erik ;
Aksnes, Ellen ;
Bakken, Heidi Nygaard ;
Maehlum, Torbjorn ;
Walloe, Anders ;
Nordsletten, Lars .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07) :815-819
[10]  
Frydrysek K, 2011, ENGINEERING MECHANICS 2011, P151