Evaluation of detection sensitivity in comprehensive two-dimensional liquid chromatography separations of an active pharmaceutical ingredient and its degradants

被引:67
作者
Stoll, Dwight R. [1 ]
Talus, Eric S. [1 ]
Harmes, David C. [1 ]
Zhang, Kelly [2 ]
机构
[1] Gustavus Adolphus Coll, St Peter, MN 56082 USA
[2] Genentech Inc, San Francisco, CA 94080 USA
基金
美国国家科学基金会;
关键词
Liquid chromatography; Comprehensive; Two dimensional; Pharmaceutical analysis; Sensitivity; Degradation; PEAK-CAPACITY; INJECTION VOLUME; RESOLVING POWER; SAMPLING TIME; PERFORMANCE; RESOLUTION; ORTHOGONALITY; MODULATION; COLUMNS;
D O I
10.1007/s00216-014-8036-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, we describe the findings of a study aimed at assessing the detection sensitivity of comprehensive two-dimensional high-performance liquid chromatography (LCxLC) separation of a degraded active pharmaceutical ingredient (API) with UV absorption as the detection technique. Specifically, we have examined the impact of the volume and solvent composition (referred to as "interface conditions") of fractions of first-dimension column effluent transferred to the second dimension for further separation on the ability to resolve and detect low-abundance compounds. Historically, LCxLC has been perceived as being inferior to 1D-LC from the point of view of detection sensitivity. In this work, we demonstrate that LCxLC is sufficiently sensitive to be useful in the pharmaceutical context where in general impurities present at 0.05 % (relative to the API concentration) should be quantified. Moreover, we find that this level of sensitivity is only attained under certain conditions: dilution of the first column effluent with weak solvent (water in this case) prior to injection into the second-dimension column is very beneficial because it promotes focusing of the analyte band in the second column, thereby improving the detection sensitivity of the LCxLC system; and, quantitation limits are also a strong function of peak location in the second-dimension separation window, where baseline disturbances near the dead time of the second column can limit reliable detection of low-abundance compounds.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 38 条
  • [1] Comparison of different statistical approaches to evaluate the orthogonality of chromatographic separations: Application to reverse phase systems
    Al Bakain, Ramia
    Rivals, Isabelle
    Sassiat, Patrick
    Thiebaut, Didier
    Hennion, Marie-Claire
    Euvrard, Guillaume
    Vial, Jerome
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (20) : 2963 - 2975
  • [2] Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension
    Alexander, Anthony J.
    Ma, Lianjia
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) : 1338 - 1345
  • [3] [Anonymous], 2005, INT C HARM ICH GUID
  • [4] [Anonymous], 1996, INT C HARM ICH GUID
  • [5] [Anonymous], 2006, INT C HARM ICH GUID
  • [6] Choosing sample volume to achieve maximum detection sensitivity and resolution with high-performance liquid chromatography columns of 1.0, 2.1 and 4.6 mm ID
    Bakalyar, SR
    Phipps, C
    Spruce, B
    Olsen, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) : 167 - 185
  • [7] Optimal gradient operation in comprehensive liquid chromatography x liquid chromatography systems with limited orthogonality
    Bedani, Filippo
    Kok, Wim Th.
    Janssen, Hans-Gerd
    [J]. ANALYTICA CHIMICA ACTA, 2009, 654 (01) : 77 - 84
  • [8] The development of an evaluation method for capture columns used in two-dimensional liquid chromatography
    Cao, Liwei
    Yu, Danhua
    Wang, Xinliang
    Ke, Yanxiong
    Jin, Yu
    Liang, Xinmiao
    [J]. ANALYTICA CHIMICA ACTA, 2011, 706 (01) : 184 - 190
  • [9] Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations
    Davis, Joe M.
    Stoll, Dwight R.
    Carr, Peter W.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (02) : 461 - 473
  • [10] Exploring the Possibilities of Cryogenic Cooling in Liquid Chromatography for Biological Applications: A Proof of Principle
    Eghbali, Hamed
    Sandra, Koen
    Tienpont, Bart
    Eeltink, Sebastiaan
    Sandra, Pat
    Desmet, Gert
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (04) : 2031 - 2037