Biomechanical Evaluation of Suture Configurations in Lesser Toe Plantar Plate Repairs

被引:5
作者
Finney, Fred T. [1 ]
Lee, Simon [1 ]
Scott, Jaron [1 ]
Irwin, Todd A. [2 ]
Holmes, James R. [1 ]
Talusan, Paul G. [1 ]
机构
[1] Univ Michigan Hlth Syst, Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI USA
[2] OrthoCarolina, Charlotte, NC USA
关键词
plantar plate; lesser toe; suture technqiues; METATARSOPHALANGEAL JOINT INSTABILITY; ROTATOR CUFF REPAIRS; 2ND TOE; SURGICAL-TREATMENT; WEIL OSTEOTOMY; DEFORMITY; RECONSTRUCTION; STABILITY; DIAGNOSIS; PATHOLOGY;
D O I
10.1177/1071100718758258
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Lesser toe metatarsal-phalangeal (MTP) joint instability can be a major source of pain and dysfunction. Instability occurs when there is incompetence of the plantar plate and/or collateral ligaments. Newer operative treatments focus on performing anatomic repairs of the plantar plate. The goal of this study was to compare the biomechanical properties of 3 suture configurations that may be used for plantar plate repairs. Methods: Biomechanical analysis of 27 lesser toe plantar plates from fresh frozen human cadavers was completed. The plantar plate was detached from the proximal phalanx, and suture was placed in the distal plantar plate in a horizontal mattress, luggage-tag, or Mason-Allen suture configuration. Cyclic loading followed by load-to-failure testing was performed. Results: There was a significant difference in peak load-to-failure force between constructs (mattress: 115.53 15.95 N; luggage-tag 102.42 19.33 N; Mason-Allen: 89.96 +/- 15.78 N; P = .015). Post hoc analysis demonstrated that the mattress configuration had significantly higher load-to-failure force compared with the Mason-Allen configuration (P = .004). There were no significant differences between the mattress and the luggage-tag configurations or the luggage-tag and the Mason-Allen configurations. There were no differences in construct stiffness, axial displacement at the time of failure, or number of cycles required to produce 2 mm of displacement. Conclusion: The mattress configuration demonstrated better peak load-to-failure force compared with the Mason-Allen configuration but was not statistically different from the luggage-tag configuration. Although not significant, the mattress configuration trended toward higher load-to-failure force compared with the luggage-tag. Clinical Relevance: The horizontal mattress stitch may be the biomechanically superior configuration in plantar plate repairs.
引用
收藏
页码:836 / 842
页数:7
相关论文
共 40 条
[1]  
Arthrex, 2015, CPR COMPL PLANT PLAT
[2]   Role of Collateral Ligaments in Metatarsophalangeal Stability: A Cadaver Study [J].
Barg, Alexej ;
Courville, Xan F. ;
Nickisch, Florian ;
Bachus, Kent N. ;
Saltzman, Charles L. .
FOOT & ANKLE INTERNATIONAL, 2012, 33 (10) :877-882
[3]   Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure [J].
Burkhart, SS ;
Johnson, TC ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (02) :172-176
[4]   Role of Plantar Plate and Surgical Reconstruction Techniques on Static Stability of Lesser Metatarsophalangeal Joints: A Biomechanical Study [J].
Chalayon, Ornusa ;
Chertman, Carla ;
Guss, Andrew D. ;
Saltzman, Charles L. ;
Nickisch, Florian ;
Bachus, Kent N. .
FOOT & ANKLE INTERNATIONAL, 2013, 34 (10) :1436-1442
[5]   Arthroscopic rotator cuff repairs: An anatomic and biomechanical rationale for different suture-anchor repair configurations [J].
Cole, Brian J. ;
ElAttrache, Neal S. ;
Anbari, Ammar .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :662-669
[6]   Metatarsophalangeal Joint Pathology in Crossover Second Toe Deformity: A Cadaveric Study [J].
Coughlin, Michael J. ;
Schutt, Shane A. ;
Hirose, Christopher B. ;
Kennedy, Michael J. ;
Grebing, Brett R. ;
Smith, Bertil W. ;
Cooper, M. Truitt ;
Golano, Pau ;
Viladot, Ramon ;
Alvarez, Fernando .
FOOT & ANKLE INTERNATIONAL, 2012, 33 (02) :133-140
[7]   CROSSOVER SECOND TOE DEFORMITY [J].
COUGHLIN, MJ .
FOOT & ANKLE, 1987, 8 (01) :29-39
[8]   2ND METATARSOPHALANGEAL JOINT INSTABILITY IN THE ATHLETE [J].
COUGHLIN, MJ .
FOOT & ANKLE, 1993, 14 (06) :309-319
[9]   Mode of failure for rotator cuff repair with suture anchors identified at revision surgery [J].
Cummins, CA ;
Murrell, GAC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (02) :128-133
[10]   TREATMENT OF PAINFUL SUBLUXATION OR DISLOCATION AT THE 2ND AND 3RD METATARSOPHALANGEAL JOINTS BY PARTIAL PROXIMAL PHALANX EXCISION AND SUBTOTAL WEBBING [J].
DALY, PJ ;
JOHNSON, KA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (278) :164-170