Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog

被引:106
|
作者
Koch, F. P. [1 ]
Weng, D. [2 ]
Kraemer, S. [1 ]
Biesterfeld, S. [3 ]
Jahn-Eimermacher, A. [4 ]
Wagner, W. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Oral & Maxillofacial Surg, Fac Med, D-55131 Mainz, Germany
[2] Univ Wurzburg, Dept Prosthodont, Sch Dent Med, Wurzburg, Germany
[3] Johannes Gutenberg Univ Mainz, Inst Pathol, D-6500 Mainz, Germany
[4] Johannes Gutenberg Univ Mainz, Inst Med Biometry Epidemiol & Informat, Mainz, Germany
关键词
animal experiments; healing mode; histomorphometric analysis; osseointegration; zirconia implant; INTERFACE;
D O I
10.1111/j.1600-0501.2009.01832.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. Material and methods Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically assess the bone-to-implant contact (BIC) rates and the bone levels (BL) of the implants. Results All 48 implants were osseointegrated clinically and histologically. Histomorphometrically, BL in the crestal implant part did not differ significantly with regard to material type or healing modality. The submerged coated zirconia implants tended to offer the most stable crestal BL. The histometric results reflected the different healing modes by establishing different BL. The median BIC of the apical implant part of the zirconia and titanium group amounted to 59.2% for uncoated zirconia, 58.3% for coated zirconia, 26.8% for the synthetic material and 41.2% for titanium implants. Conclusions Within the limits of this animal study, it is concluded that zirconia implants are capable of establishing close BIC rates similar to what is known from the osseointegration behaviour of titanium implants with the same surface modification and roughness. To cite this article:Koch FP, Weng D, Kramer S, Biesterfeld S, Jahn-Eimermacher A, Wagner W. Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog.Clin. Oral Impl. Res. 21, 2010; 350-356.doi: 10.1111/j.1600-0501.2009.01832.x.
引用
收藏
页码:350 / 356
页数:7
相关论文
共 50 条
  • [1] Soft Tissue Healing at One-Piece Zirconia Implants Compared to Titanium and PEEK Implants of Identical Design: A Histomorphometric Study in the Dog
    Koch, Felix Peter
    Weng, Dietmar
    Kraemer, Sonja
    Wagner, Wilfried
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2013, 33 (05) : 669 - U127
  • [2] One-piece zirconia ceramic implants An alternative restoration concept to titanium implants
    Gahlert, Michael
    Roehling, Stefan
    IMPLANTOLOGIE, 2022, 30 (01): : 79 - 91
  • [3] Osseointegration of zirconia implants compared with titanium: An in vivo study
    Depprich R.
    Zipprich H.
    Ommerborn M.
    Naujoks C.
    Wiesmann H.-P.
    Kiattavorncharoen S.
    Lauer H.-C.
    Meyer U.
    Kübler N.R.
    Handschel J.
    Head & Face Medicine, 4 (1)
  • [4] Experimental and Numeric Stress Analysis of Titanium and Zirconia One-Piece Dental Implants
    Mobilio, Nicola
    Stefanoni, Filippo
    Contiero, Paolo
    Mollica, Francesco
    Catapano, Santo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : E135 - E142
  • [5] Stress distribution in a zirconia one-piece dental implant
    Correia, A.
    Reis Campos, J. C.
    Couto Viana, P.
    Kovacs, Z.
    Ramos, N. V.
    Vaz, M.
    BIODENTAL ENGINEERING II, 2014, : 173 - 175
  • [6] One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study
    Siddiqi, A.
    Duncan, W. J.
    De Silva, R. K.
    Zafar, S.
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [7] One-Piece Titanium Implants: Retrospective Case Series
    Wagner, Gunar
    Hartung, Dieter
    CASE REPORTS IN DENTISTRY, 2021, 2021
  • [8] In Vitro Fatigue and Fracture Strength Testing of One-Piece Zirconia Implant Abutments and Zirconia Implant Abutments Connected to Titanium Cores
    Stimmelmayr, Michael
    Sagerer, Stefanie
    Erdelt, Kurt
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 488 - 493
  • [9] Fractographic analyses of failed one-piece zirconia implant restorations
    Oilo, Marit
    Arola, Dwayne
    DENTAL MATERIALS, 2018, 34 (06) : 922 - 931
  • [10] Clinical and radiographic prospective study of customized one-piece titanium and one-piece fusion-sputtered zirconia implants: five-year mean follow-up
    Mahy Hassouna
    Walid Al-Zordk
    Moustafa Aboshilib
    Mohamed Ghazy
    BMC Oral Health, 22