Bayesian inference of a negative quantity from positive measurement results

被引:0
作者
Calonico, D. [1 ]
Levi, F. [1 ]
Lorini, L. [1 ]
Mana, G. [1 ]
机构
[1] INRIM, I-10135 Turin, Italy
来源
2009 JOINT MEETING OF THE EUROPEAN FREQUENCY AND TIME FORUM AND THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2 | 2009年
关键词
PRIMARY FREQUENCY STANDARD; UNCERTAINTY EVALUATION; CSF1;
D O I
10.1109/FREQ.2009.5168246
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper Bayesian analysis is applied to a Cesium fountain frequency standard to estimate the density shift correction and its uncertainty. Cesium fountain frequency-standards realize the second in the International System of Units with a relative uncertainty approaching 10(-16). Among the main contributions to the accuracy budget, cold collisions play an important role because of the so called atomic density shift of the reference atomic transition. The Bayes theorem allows the a priori knowledge of the sign of the collisional correction that is definitively negative to be rigourously embedded into the analysis. In the H-maser frequency measurements using INRIM Cesium fountain as reference, we used the Bayesian analysis and we report a reduction on the final combined uncertainty by more than 25% that demonstrates the Bayesian analysis as a relevant tool in primary frequency-metrology.
引用
收藏
页码:568 / 572
页数:5
相关论文
共 18 条
[1]  
[Anonymous], 1937, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences
[2]   Comparison between frequency standards in Europe and the USA at the 10-15 uncertainty level [J].
Bauch, A ;
Achkar, J ;
Bize, S ;
Calonico, D ;
Dach, R ;
Hlavac, R ;
Lorini, L ;
Parker, T ;
Petit, G ;
Piester, D ;
Szymaniec, K ;
Uhrich, P .
METROLOGIA, 2006, 43 (01) :109-120
[3]   Bayesian inference of a negative quantity from positive measurement results [J].
Calonico, D. ;
Levi, F. ;
Lorini, L. ;
Mana, G. .
METROLOGIA, 2009, 46 (03) :267-271
[4]   PROBABILITY, FREQUENCY AND REASONABLE EXPECTATION [J].
COX, RT .
AMERICAN JOURNAL OF PHYSICS, 1946, 14 (01) :1-13
[5]   NIST-F1: recent improvements and accuracy evaluations [J].
Heavner, TP ;
Jefferts, SR ;
Donley, EA ;
Shirley, JH ;
Parker, TE .
METROLOGIA, 2005, 42 (05) :411-422
[6]  
Jaynes ET., 2003, Probability Theory
[7]   Evaluation of caesium atomic fountain NICT-CsF1 [J].
Kumagai, M. ;
Ito, H. ;
Kajita, M. ;
Hosokawa, M. .
METROLOGIA, 2008, 45 (02) :139-148
[8]  
Leo PJ, 2001, PHYS REV LETT, V86, P3743, DOI 10.1103/PhysRevLett86.3743
[9]   IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations [J].
Levi, F. ;
Calonico, D. ;
Lorini, L. ;
Godone, A. .
METROLOGIA, 2006, 43 (06) :545-555
[10]   Systematic shift uncertainty evaluation of IEN CSF1 primary frequency standard [J].
Levi, F ;
Lorini, L ;
Calonico, D ;
Godone, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) :267-271