Are commercially-available precontoured anatomical clavicle plating systems offering the purported superior optimum fitting to the clavicle? A cadaveric analysis and review of literature

被引:7
作者
Bauer, D. E. [1 ]
Hingsammer, A. [1 ]
Schenk, P. [1 ]
Vlachopoulos, L. [2 ]
Imam, M. A. [1 ]
Fuernstahl, P. [2 ]
Meyer, D. C. [1 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthopaed, CH-8008 Zurich, Switzerland
[2] Balgrist Univ Hosp, Comp Assisted Res & Dev Grp, CH-8008 Zurich, Switzerland
关键词
Clavicle; Fracture; Midshaft; Reconstruction plate; Three-dimensional; NONOPERATIVE TREATMENT; COMPRESSION PLATE; FRACTURES; FIXATION; EPIDEMIOLOGY; RECONSTRUCTION; OSTEOSYNTHESIS; OSTEOTOMIES; STABILITY; NONUNION;
D O I
10.1016/j.otsr.2018.01.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The indication for operative treatment of displaced midshaft clavicle fractures remains controversial. However, if plate fixation is considered, implant prominence and skin irritation are the most common causes for re-operation. Low profile implants as well as closely contouring plates to the individual anatomy may reduce these complications. The aim of this study was to compare the fitting accuracy and implant prominence of 3.5 mm pelvic reconstruction plates (PRP) with pre-contoured anatomical clavicle plates (PACP) for midshaft clavicle fractures. Methods: Three-dimensional data of the largest, median and smallest male and female clavicle of an existing database of 89 cadaveric clavicles were included for analysis. A three-dimensional model of a commercially available PACP was used for digitally positioning of the plate on the segmented clavicles. Three-dimensional printouts of each clavicle were produced and the 3.5 mm reconstruction plates were manually bent and positioned by the senior author. Computed tomography scans and three-dimensional reconstructions were then obtained to digitally compare the fitting accuracy and implant prominence. Results: Pelvic reconstruction plates offered superior fitting accuracy and lower implant prominence compared to PACP. The largest difference in implant prominence was observed in large sized female clavicles and measured 3.6 mm. Conclusion: Both, the less costly PRP plates and commercially available PACP for midshaft fractures of the clavicle demonstrated a clinically acceptable fitting accuracy. The manually bent pelvic-reconstruction plates demonstrated reduced implant prominence with superior fitting. Hypothetically this might contribute to a reduced rate of reoperation. (c) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:755 / 758
页数:4
相关论文
共 32 条
  • [1] TREATMENT OF CLAVICULAR FRACTURES - FIGURE-OF-8 BANDAGE VERSUS A SIMPLE SLING
    ANDERSEN, K
    JENSEN, PO
    LAURITZEN, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (01): : 71 - 74
  • [2] Biomechanical evaluation of clavicle fracture plating techniques: Does a locking plate provide improved stability?
    Celestre, Paul
    Roberston, Claire
    Mahar, Andrew
    Oka, Richard
    Meunier, Matthew
    Schwartz, Alexandra
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (04) : 241 - 247
  • [3] OUTCOME OF CLAVICULAR FRACTURE IN 89 PATIENTS
    ESKOLA, A
    VAINIONPAA, S
    MYLLYNEN, P
    PATIALA, H
    ROKKANEN, P
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (06) : 337 - 338
  • [4] A three-dimensional analysis of bilateral directional asymmetry in the human clavicle
    Fatah, Emam ElHak Abdel
    Shirley, Natalie R.
    Mahfouz, Mohamed R.
    Auerbach, Benjamin M.
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2012, 149 (04) : 547 - 559
  • [5] Simultaneous Segmentation and Multiresolution Nonrigid Atlas Registration
    Gass, Tobias
    Szekely, Gabor
    Goksel, Orcun
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2014, 23 (07) : 2931 - 2943
  • [6] Does plate type influence the clinical outcomes and implant removal in midclavicular fractures fixed with 2.7-mm anteroinferior plates? A retrospective cohort study
    Gilde, Alex K.
    Jones, Clifford B.
    Sietsema, Debra L.
    Hoffmann, Martin F.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [7] Is plating of mid-shaft clavicular fractures possible with a conventional straight 3.5 millimeter locking compression plate?
    Grechenig, Wolfgang
    Heidari, Nima
    Leitgoeb, Ottmal
    Prager, Walter
    Pichler, Wolfgang
    Weinber, Annelie M.
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2011, 45 (02) : 115 - 119
  • [8] Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
    Harnroongroj, T
    Vanadurongwan, V
    [J]. CLINICAL BIOMECHANICS, 1996, 11 (05) : 290 - 294
  • [9] Three-dimensional corrective osteotomies of mal-united claviclesis the contralateral anatomy a reliable template for reconstruction?
    Hingsammer, Andreas M.
    Lazaros, Vlachopoulos
    Dominik, Meyer C.
    Fuernstahl, Philipp
    [J]. CLINICAL ANATOMY, 2015, 28 (07) : 865 - 871
  • [10] Clavicular anatomy and the applicability of precontoured plates
    Huang, Jerry I.
    Toogood, Paul
    Chen, Michael R.
    Wilber, John H.
    Cooperman, Daniel R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (10) : 2260 - 2265