Tracking errors in a prototype real-time tumour tracking system

被引:30
作者
Sharp, GC [1 ]
Jiang, SB
Shimizu, S
Shirato, H
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Hokkaido Univ, Sch Med, Dept Radiat Med, Sapporo, Hokkaido 060, Japan
关键词
D O I
10.1088/0031-9155/49/23/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In motion-compensated radiation therapy, radio-opaque markers can be implanted in or near a tumour and tracked in real-time using fluoroscopic imaging. Tracking these implanted markers gives highly accurate position information, except when tracking fails due to poor or ambiguous imaging conditions. This study investigates methods for automatic detection of tracking errors, and assesses the frequency and impact of tracking errors on treatments using the prototype real-time tumour tracking system. We investigated four indicators for automatic detection of tracking errors. and found that the, distance between corresponding rays was most effective. We also found that tracking errors cause a loss of gating efficiency of between 7.6 and 10.2%. The incidence of treatment beam delivery during tracking errors was estimated at between 0.8% and 1.25%.
引用
收藏
页码:5347 / 5356
页数:10
相关论文
共 31 条
[11]   Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center [J].
Kubo, HD ;
Len, PM ;
Minohara, S ;
Mostafavi, H .
MEDICAL PHYSICS, 2000, 27 (02) :346-353
[12]   Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment [J].
Mageras, GS ;
Yorke, E .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :65-75
[13]   Respiratory gated irradiation system for heavy-ion radiotherapy [J].
Minohara, S ;
Kanai, T ;
Endo, M ;
Noda, K ;
Kanazawa, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04) :1097-1103
[14]   Tracking moving organs in real time [J].
Murphy, MJ .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :91-100
[15]   Patterns of patient movement during frameless image-guided radiosurgery [J].
Murphy, MJ ;
Chang, SD ;
Gibbs, IC ;
Le, QT ;
Hai, J ;
Kim, D ;
Martin, DP ;
Adler, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (05) :1400-1408
[16]   Fiducial-based targeting accuracy for external-beam radiotherapy [J].
Murphy, MJ .
MEDICAL PHYSICS, 2002, 29 (03) :334-344
[17]   IRRADIATION SYNCHRONIZED WITH RESPIRATION GATE [J].
OHARA, K ;
OKUMURA, T ;
AKISADA, M ;
INADA, T ;
MORI, T ;
YOKOTA, H ;
CALAGUAS, MJB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (04) :853-857
[18]  
OZHASOGLU C, 2000, P 14 INT C COMP ASS, P691
[19]  
Ramsey C R, 1999, Med Dosim, V24, P115, DOI 10.1016/S0958-3947(99)00006-0
[20]   A comparison of beam characteristics for gated and nongated clinical x-ray beams [J].
Ramsey, CR ;
Cordrey, IL ;
Oliver, AL .
MEDICAL PHYSICS, 1999, 26 (10) :2086-2091