Tracking errors in a prototype real-time tumour tracking system

被引:30
作者
Sharp, GC [1 ]
Jiang, SB
Shimizu, S
Shirato, H
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Hokkaido Univ, Sch Med, Dept Radiat Med, Sapporo, Hokkaido 060, Japan
关键词
D O I
10.1088/0031-9155/49/23/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In motion-compensated radiation therapy, radio-opaque markers can be implanted in or near a tumour and tracked in real-time using fluoroscopic imaging. Tracking these implanted markers gives highly accurate position information, except when tracking fails due to poor or ambiguous imaging conditions. This study investigates methods for automatic detection of tracking errors, and assesses the frequency and impact of tracking errors on treatments using the prototype real-time tumour tracking system. We investigated four indicators for automatic detection of tracking errors. and found that the, distance between corresponding rays was most effective. We also found that tracking errors cause a loss of gating efficiency of between 7.6 and 10.2%. The incidence of treatment beam delivery during tracking errors was estimated at between 0.8% and 1.25%.
引用
收藏
页码:5347 / 5356
页数:10
相关论文
共 31 条
[1]   Image-guided robotic radiosurgery [J].
Adler, JR ;
Murphy, MJ ;
Chang, SD ;
Hancock, SL .
NEUROSURGERY, 1999, 44 (06) :1299-1306
[3]   Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors [J].
Berbeco, RI ;
Jiang, SB ;
Sharp, GC ;
Chen, GTY ;
Mostafavi, H ;
Shirato, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) :243-255
[4]  
Bishop C. M., 1996, Neural networks for pattern recognition
[5]   Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy [J].
Harada, T ;
Shirato, H ;
Ogura, S ;
Oizumi, S ;
Yamazaki, K ;
Shimizu, S ;
Onimaru, R ;
Miyasaka, K ;
Nishimura, M ;
Dosaka-Akita, H .
CANCER, 2002, 95 (08) :1720-1727
[6]  
Hart, 2006, PATTERN CLASSIFICATI
[7]   Evaluation of a miniature electromagnetic position tracker [J].
Hummel, J ;
Figl, M ;
Kollmann, C ;
Bergmann, H ;
Birkfellner, W .
MEDICAL PHYSICS, 2002, 29 (10) :2205-2212
[8]   Potential radiotherapy improvements with respiratory gating [J].
Keall P.J. ;
Kini V.R. ;
Vedam S.S. ;
Mohan R. .
Australasian Physics & Engineering Sciences in Medicine, 2002, 25 (1) :1-6
[9]   Motion adaptive x-ray therapy: a feasibility study [J].
Keall, PJ ;
Kini, VR ;
Vedam, SS ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) :1-10
[10]   Respiration gated radiotherapy treatment: A technical study [J].
Kubo, HD ;
Hill, BC .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01) :83-91