The Evaluation of Active Phase Control under Deliberate Disturbance Frequency based on Heterodyne Detection Method for Coherent Laser Beam Combining

被引:0
|
作者
Lee, Sung Rae [1 ]
Jeong, Yoonseob [1 ]
Lee, Yong Soo [2 ]
Lee, Jung Hwan [3 ]
Oh, Kyunghwan [1 ]
机构
[1] Yonsei Univ, Photon Device Phys Lab, 50 Yonsei Ro, Seoul 120749, South Korea
[2] Doosan DST, Seoul 642120, South Korea
[3] Agcy Def Dev, Taejon 305600, South Korea
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In all-fiber coherent laser beam combining under active phase control by heterodyne detection, we report a relationship between deliberate disturbance frequency and control bandwidth for adequate phase locking.
引用
收藏
页码:63 / +
页数:2
相关论文
共 49 条
  • [41] A Seamless Transfer Algorithm Based on Active Frequency Detection with Feedforward Control Method in Distributed Generation System
    Kim, K.
    Shin, D.
    Kim, H. -J.
    Lee, J. -P.
    Kim, T. -J.
    Yoo, D. -W.
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [42] Target Detection Method Based on Adaptive Step-Size SAMP Combining Off-Grid Correction for Coherent Frequency-Agile Radar
    Chang, Jiayun
    Fu, Xiongjun
    Zhan, Kai
    Zhao, Xuezhou
    Dong, Jian
    Wu, Junqiang
    REMOTE SENSING, 2023, 15 (20)
  • [43] Frequency-Locked Loop Based New Automatic Phase-Shift Method for Active Islanding Detection of Three-Phase MicroGrid
    Gulipalli, Surya Chandra
    Chou, Pei-Han
    Chen, Yen-Ming
    Liu, Ting-I
    Chu, Chia-Chi
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (05) : 5257 - 5268
  • [44] Phase lead error-based active disturbance rejection control for 1000 MW ultra-supercritical unit under flexible operation
    Pang, Dawei
    Niu, Yuguang
    Du, Ming
    ENERGY, 2025, 319
  • [45] Combining an optimisation-based frequency band identification method with historical data for novelty detection under time-varying operating conditions
    Schmidt, Stephan
    Gryllias, Konstantinos C.
    MEASUREMENT, 2021, 169
  • [46] Energy quality improvement of three-phase shunt active power filter under different voltage conditions based on predictive direct power control with disturbance rejection principle
    Ouchen, Sabir
    Gaubert, Jean-Paul
    Steinhart, Heinrich
    Betka, Achour
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2019, 158 : 506 - 519
  • [47] A Hybrid-Frame Control Based Impedance Shaping Method to Extend the Effective Damping Frequency Range of the Three-Phase Adaptive Active Damper
    Lin, Zhiheng
    Ruan, Xinbo
    Zhang, Hao
    Wu, Liguo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (01) : 509 - 521
  • [48] Active arc-suppression method based on double closed-loop control under single-phase grounding faults in distribution networks
    Chen R.
    Zhou F.
    Weng H.
    Wang W.
    Zeng X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2017, 41 (05): : 128 - 133
  • [49] A modified synchronous detection method with power factor control and suitable performance under non-ideal grid voltage applicable for three phase active power filters
    Pichan, Mohammad
    Fazeli, Mehdi
    Abrishamifar, Adib
    Arefian, Masoud
    2014 22ND IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2014, : 719 - 724