Sensing technology based quality control and warning systems for sleeve grouting of prefabricated buildings

被引:30
作者
Yao, Fuyi [1 ]
Ji, Yingbo [2 ]
Tong, Wenjing [2 ]
Li, Hong Xian [3 ]
Liu, Guiwen [1 ]
机构
[1] Chongqing Univ, Sch Management Sci & Real Estate, Chongqing 400044, Peoples R China
[2] North China Univ Technol, Sch Civil Engn, Beijing 100144, Peoples R China
[3] Deakin Univ, Sch Architecture & Built Environm, Locked Bag 20001, Geelong, Vic 20001, Australia
基金
国家重点研发计划;
关键词
Prefabricated buildings (PB); Quality control; Sleeve grouting; Real-time early warning system; Sensing technology; CONSTRUCTION; MANAGEMENT; PERFORMANCE; EMISSION; INTERNET; SAFETY; MODEL; BIM;
D O I
10.1016/j.autcon.2020.103537
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sleeve grouting is widely used for connecting prefabricated buildings (PB) components to form key nodes. Although some nondestructive testing techniques have been tried for the inspection of grouting defects, the application effect is not satisfactory due to its detection lag, poor anti-interference, and program complexity. The quality level of PB nodes is still uncertain, and early warning has not been achieved. This paper develops a quality control model and carries on real-time early warning system application to quality management of PB nodes. Toward this aim, sensing technology is applied to collect quality data, including grouting compactness and mechanical properties inside the sleeves for a prefabricated uniformed layer. This quality control model is verified and validated through a real-world PB project. The results show that it can effectively improve the inspection efficiency and accuracy in PB node quality, specifically in the real-time detection, monitoring and early warning of the quality level.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Application of HVAC Systems with Control Based on PMV Index in University Buildings with Complex Topology
    Conceicao, Eusebio Z. E.
    Gomes, Joao M. M.
    Ruano, Antonio E.
    IFAC PAPERSONLINE, 2018, 51 (10): : 20 - 25
  • [32] Analysis and optimization of HVAC control systems based on energy and performance considerations for smart buildings
    Homod, Raad Z.
    RENEWABLE ENERGY, 2018, 126 : 49 - 64
  • [33] The intelligent quality control technology system Based on the integration methods of SPC and EPC
    Jiang, Zhongqiu
    INFORMATION TECHNOLOGY APPLICATIONS IN INDUSTRY, PTS 1-4, 2013, 263-266 : 839 - 842
  • [34] Research on the quality control strategy of marine engineering based on big data technology
    Yuan J.
    Yu H.
    Sun Z.
    Li Y.
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [35] Research on Quality Control Technology in Manufacturing Process Based on Flexibility of Production Capability
    Wang, Hui
    Li, Gangyan
    Li, Guifu
    2007 INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-15, 2007, : 5115 - +
  • [36] Research on quality control technology in manufacturing process based on flexibility of production capability
    Wang, Hui
    Li, Gangyan
    Li, Guifu
    International Conference on Management Innovation, Vols 1 and 2, 2007, : 849 - 853
  • [37] STUDY ON THE QUALITY CONTROL METHODS OF CLUSTER-BASED REMOTE SENSING IMAGE PROCESSING
    Xia, L.
    Zhao, L. B.
    Zhang, X. P.
    Zhou, X. M.
    8TH INTERNATIONAL SYMPOSIUM ON SPATIAL DATA QUALITY, 2013, 40-2 (w1): : 31 - 34
  • [38] A Task Ontology-based Model for Quality Control in Crowdsourcing Systems
    Alabduljabbar, Reham
    Al-Dossari, Hmood
    2016 RESEARCH IN ADAPTIVE AND CONVERGENT SYSTEMS, 2016, : 22 - 28
  • [39] Manufacturing and quality control of plasmid-based gene expression systems
    Durland, RH
    Eastman, EM
    ADVANCED DRUG DELIVERY REVIEWS, 1998, 30 (1-3) : 33 - 48
  • [40] An event-driven multi-agent based distributed optimal control strategy for HVAC systems in IoT-enabled smart buildings
    Li, Wenzhuo
    Li, Hangxin
    Wang, Shengwei
    AUTOMATION IN CONSTRUCTION, 2021, 132