Deep Convolutional Neural Network for Inverse Problems in Imaging

被引:1583
作者
Jin, Kyong Hwan [1 ]
McCann, Michael T. [1 ,2 ]
Froustey, Emmanuel [1 ,3 ]
Unser, Michael [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Ctr Biomed Imaging, Signal Proc Core, CH-1015 Lausanne, Switzerland
[3] Dassault Aviat, F-92210 St Cloud, France
关键词
Image restoration; image reconstruction; tomography; computed tomography; magnetic resonance imaging; biomedical signal processing; biomedical imaging; reconstruction algorithms; RAY CT RECONSTRUCTION; THRESHOLDING ALGORITHM; TOMOGRAPHY; TRANSFORM; SHRINKAGE; MRI;
D O I
10.1109/TIP.2017.2713099
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, we propose a novel deep convolutional neural network (CNN)-based algorithm for solving ill-posed inverse problems. Regularized iterative algorithms have emerged as the standard approach to ill-posed inverse problems in the past few decades. These methods produce excellent results, but can be challenging to deploy in practice due to factors including the high computational cost of the forward and adjoint operators and the difficulty of hyperparameter selection. The starting point of this paper is the observation that unrolled iterative methods have the form of a CNN (filtering followed by pointwise non-linearity) when the normal operator (H* H, where H* is the adjoint of the forward imaging operator, H) of the forward model is a convolution. Based on this observation, we propose using direct inversion followed by a CNN to solve normal-convolutional inverse problems. The direct inversion encapsulates the physical model of the system, but leads to artifacts when the problem is ill posed; the CNN combines multiresolution decomposition and residual learning in order to learn to remove these artifacts while preserving image structure. We demonstrate the performance of the proposed network in sparse-view reconstruction (down to 50 views) on parallel beam X-ray computed tomography in synthetic phantoms as well as in real experimental sinograms. The proposed network outperforms total variation-regularized iterative reconstruction for the more realistic phantoms and requires less than a second to reconstruct a 512 x 512 image on the GPU.
引用
收藏
页码:4509 / 4522
页数:14
相关论文
共 66 条
  • [1] Fast Image Recovery Using Variable Splitting and Constrained Optimization
    Afonso, Manya V.
    Bioucas-Dias, Jose M.
    Figueiredo, Mario A. T.
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2010, 19 (09) : 2345 - 2356
  • [2] [Anonymous], 2017, SPIE MED IMAG
  • [3] [Anonymous], 1995, Translation-invariant De-noising
  • [4] [Anonymous], PROC CVPR IEEE
  • [5] [Anonymous], 2013, P SMRT C
  • [6] [Anonymous], PROC CVPR IEEE
  • [7] [Anonymous], 2016, MICRO, DOI 10.1109/MICRO.2016.7783721
  • [8] [Anonymous], 2015, PROC CVPR IEEE
  • [9] [Anonymous], 2010, P 27 INT C INT C MAC
  • [10] [Anonymous], 1999, WAVELET TOUR SIGNAL