Intuitive real-time control strategy for high-density myoelectric hand prosthesis using deep and transfer learning

被引:42
作者
Tam, Simon [1 ]
Boukadoum, Mounir [2 ]
Campeau-Lecours, Alexandre [3 ,4 ]
Gosselin, Benoit [1 ]
机构
[1] Univ Laval, Dept Elect & Comp Engn, Quebec City, PQ G1V 0A6, Canada
[2] Univ Quebec Montreal UQAM, Dept Comp Engn, Montreal, PQ H2L 2C4, Canada
[3] Univ Laval, Dept Mech Engn, Quebec City, PQ G1V 0A6, Canada
[4] Ctr Interdisciplinary Res Rehabil & Social Integr, Quebec City, PQ, Canada
关键词
OF-THE-ART; GESTURE RECOGNITION;
D O I
10.1038/s41598-021-90688-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Myoelectric hand prostheses offer a way for upper-limb amputees to recover gesture and prehensile abilities to ease rehabilitation and daily life activities. However, studies with prosthesis users found that a lack of intuitiveness and ease-of-use in the human-machine control interface are among the main driving factors in the low user acceptance of these devices. This paper proposes a highly intuitive, responsive and reliable real-time myoelectric hand prosthesis control strategy with an emphasis on the demonstration and report of real-time evaluation metrics. The presented solution leverages surface high-density electromyography (HD-EMG) and a convolutional neural network (CNN) to adapt itself to each unique user and his/her specific voluntary muscle contraction patterns. Furthermore, a transfer learning approach is presented to drastically reduce the training time and allow for easy installation and calibration processes. The CNN-based gesture recognition system was evaluated in real-time with a group of 12 able-bodied users. A real-time test for 6 classes/grip modes resulted in mean and median positive predictive values (PPV) of 93.43% and 100%, respectively. Each gesture state is instantly accessible from any other state, with no mode switching required for increased responsiveness and natural seamless control. The system is able to output a correct prediction within less than 116 ms latency. 100% PPV has been attained in many trials and is realistically achievable consistently with user practice and/or employing a thresholded majority vote inference. Using transfer learning, these results are achievable after a sensor installation, data recording and network training/fine-tuning routine taking less than 10 min to complete, a reduction of 89.4% in the setup time of the traditional, non-transfer learning approach.
引用
收藏
页数:14
相关论文
共 35 条
[1]   Real-time, simultaneous myoelectric control using a convolutional neural network [J].
Ameri, Ali ;
Akhaee, Mohammad Ali ;
Scheme, Erik ;
Englehart, Kevin .
PLOS ONE, 2018, 13 (09)
[2]  
Anam K, 2017, 2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), P100
[3]  
[Anonymous], HERO ARM USER GUIDE
[4]  
[Anonymous], LIMB ULTRA
[5]  
[Anonymous], bebionic hand - Ottobock
[6]  
[Anonymous], ImageNet
[7]   Selection of suitable hand gestures for reliable myoelectric human computer interface [J].
Castro, Maria Claudia F. ;
Arjunan, Sridhar P. ;
Kumar, Dinesh K. .
BIOMEDICAL ENGINEERING ONLINE, 2015, 14
[8]   The Reality of Myoelectric Prostheses: Understanding What Makes These Devices Difficult for Some Users to Control [J].
Chadwell, Alix ;
Kenney, Laurence ;
Thies, Sibylle ;
Galpin, Adam ;
Head, John .
FRONTIERS IN NEUROROBOTICS, 2016, 10
[9]   A real-time EMG pattern recognition system based on linear-nonlinear feature projection for a multifunction myoelectric hand [J].
Chu, Jun-Uk ;
Moon, Inhyuk ;
Mun, Mu-Seong .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (11) :2232-2239
[10]   Literature Review on Needs of Upper Limb Prosthesis Users [J].
Cordella, Francesca ;
Ciancio, Anna Lisa ;
Sacchetti, Rinaldo ;
Davalli, Angelo ;
Cutti, Andrea Giovanni ;
Guglielmelli, Eugenio ;
Zollo, Loredana .
FRONTIERS IN NEUROSCIENCE, 2016, 10