A fast and novel internal calibration method for quantitative Raman measurements on aqueous solutions

被引:12
|
作者
Duraipandian, S. [1 ]
Knopp, M. M. [2 ]
Pollard, M. R. [1 ]
Kerdoncuff, H. [1 ]
Petersen, J. C. [1 ]
Mullertz, A. [2 ]
机构
[1] Danish Fundamental Metrol, Kogle 5, DK-2970 Horsholm, Denmark
[2] Univ Copenhagen, Dept Pharm, Bioneer FARMA, DK-2100 Copenhagen, Denmark
关键词
ACTIVE INGREDIENT; SPECTROSCOPY; PARACETAMOL; TOOL;
D O I
10.1039/c8ay00753e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, aqueous paracetamol solutions were measured with varying experimental parameters (i.e., laser power and exposure time) using Raman spectroscopy. The solvent Raman spectrum peaked at 1643 cm(-1) (i.e., OH bending vibration mode of water) acts as an internal reference signal for quantifying the concentration of paracetamol. Paracetamol and water have overlapping Raman bands which complicate the quantification. Non-negative least squares fitting was used to extract the water Raman spectrum, which overlaps with the two strong paracetamol vibration modes at 1620 and 1660 cm(-1). The variations in the Raman intensities of paracetamol solutions due to the experimental variabilities were thus eliminated through normalization with the extracted water Raman spectrum. Based on the normalized spectra of paracetamol solutions, a partial least squares calibration model for quantification of paracetamol concentrations was developed, resulting in a root mean square error of cross-validation of 0.43 mg mL(-1) and a linearity of R-2 = 0.992. The model was cross-validated using two blind samples, yielding a root mean square error of prediction of 0.11 mg mL(-1). The findings of this study demonstrated that Raman spectroscopy in combination with a simple, fast and novel internal calibration method using non-negative least squares and partial least squares can be used to quantify active pharmaceutical ingredients in solution in spite of the overlapping solute and solvent signals and variations in experimental parameters.
引用
收藏
页码:3589 / 3593
页数:5
相关论文
共 12 条
  • [1] Quantitative surface-enhanced Raman measurements with embedded internal reference
    Zhou, Yan
    Ding, Rui
    Joshi, Padmanabh
    Zhang, Peng
    ANALYTICA CHIMICA ACTA, 2015, 874 : 49 - 53
  • [2] A Vertical Flow Method for Sensitive Raman Protein Measurement in Aqueous Solutions
    Li, Shu-Chi
    Hiramatsu, Hirotsugu
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 9806 - 9812
  • [3] Development and testing of a novel micro-Raman probe and application of calibration method for the quantitative analysis of microfluidic nitric acid streams
    Nelson, Gilbert L.
    Lines, Amanda M.
    Casella, Amanda J.
    Bello, Job M.
    Bryan, Samuel A.
    ANALYST, 2018, 143 (05) : 1188 - 1196
  • [4] Quantitative Analysis of Surface-Enhanced Raman Scattering Based on Internal Standard Method
    Xing Haojian
    Yin Zenghe
    Zhang Jie
    Zhu Yong
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (03)
  • [5] A novel reversed reporting agent method for surface-enhanced Raman scattering; highly sensitive detection of glutathione in aqueous solutions
    Huang, Genin Gary
    Hossain, Mohammad Kamal
    Han, Xiao X.
    Ozaki, Yukihiro
    ANALYST, 2009, 134 (12) : 2468 - 2474
  • [6] A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface
    Chang, Hyejin
    Kang, Homan
    Jeong, Sinyoung
    Ko, Eunbyeol
    Lee, Yoon-Sik
    Lee, Ho-Young
    Jeong, Dae Hong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (05)
  • [7] A method for prompt in situ uranium assay and free acidity determination in uranyl nitrate solutions by density and Raman measurements
    Berlizov, Andriy
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 320 (03) : 775 - 784
  • [8] A Simple Calibration Method of Anti-Stokes-Stokes Raman Intensity Ratios Using the Water Spectrum for Intracellular Temperature Measurements
    Yoshikawa, Yuki
    Shigeto, Shinsuke
    APPLIED SPECTROSCOPY, 2020, 74 (10) : 1295 - 1300
  • [9] Development of a Heat-Induced Surface-Enhanced Raman Scattering Sensing Method for Rapid Detection of Glutathione in Aqueous Solutions
    Huang, Genin Gary
    Han, Xiao X.
    Hossain, Mohammad Kamal
    Ozaki, Yukihiro
    ANALYTICAL CHEMISTRY, 2009, 81 (14) : 5881 - 5888
  • [10] Quantitative Detection of NADH Using a Novel Enzyme-Assisted Method Based on Surface-Enhanced Raman Scattering
    Teng, Haiyan
    Lv, Mingyang
    Liu, Luo
    Zhang, Xin
    Zhao, Yongmei
    Wu, Zhenglong
    Xu, Haijun
    SENSORS, 2017, 17 (04)