Tandem tuned mass damper inerter for passive control of buildings under seismic loads

被引:19
作者
Farzam, Maziar Fahimi [1 ]
Jalali, Himan Hojat [2 ]
机构
[1] Univ Maragheh, Fac Engn, Maragheh, Iran
[2] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
关键词
inerter; particle swarm optimization; structural control; time history analysis; tuned mass damper; VIBRATION CONTROL; DESIGN; PERFORMANCE; PARAMETERS; EARTHQUAKE;
D O I
10.1002/stc.2987
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned mass damper inerter (TMDI) is becoming a well-known device for mitigating structural vibrations. However, to be effective, the inerter needs to be connected to lower stories, which can interfere with the architectural features and therefore limit its feasibility. To overcome this challenge, a rooftop tandem tuned mass damper inerter (TTMDI) device for the structural control of a well-recognized benchmark 10-story shear building is proposed, in which the mass of the conventional TMDI is divided into two variable masses that are connected to each other using a spring and dashpot. The seven TTMDI free parameters (frequency and damping ratio of the two masses connected to the roof, the frequency and damping ratio of the connected masses, and their relative mass ratio) are optimized using particle swarm optimization algorithm (PSO) by minimizing the largest singular value of story drift transfer function. To evaluate the robustness of the optimal damper, its performance is compared to two comparable tuned TMDI configurations (TMDI-9 and TMDI-8) in both frequency and time domains under 21 far- and near-field records with forward directivity (FD) and fling step (FS) for a preselected mass ratio of 1% and three different inertance ratios. The performance indices in the time domain were selected as the maximum story drifts and absolute story acceleration. Results show that the rooftop TTMDI outperforms both TMDI configurations in both frequency and time domains, and its performance is more robust in terms of not exceeding the uncontrolled responses for most of the considered earthquake records.
引用
收藏
页数:22
相关论文
共 44 条
[1]   Estimating optimum parameters of tuned mass dampers using harmony search [J].
Bekdas, Gebrail ;
Nigdeli, Sinan Melih .
ENGINEERING STRUCTURES, 2011, 33 (09) :2716-2723
[2]   Influence of Near-Fault Ground Motions with Fling-Step and Forward-Directivity Characteristics on Seismic Response of Base-Isolated Buildings [J].
Bhagat, Satish ;
Wijeyewickrema, Anil C. ;
Subedi, Naresh .
JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (03) :455-474
[3]   Tuned tandem mass dampers-inerters with broadband high effectiveness for structures under white noise base excitations [J].
Cao, Liyuan ;
Li, Chunxiang .
STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (04)
[4]   A tuning algorithm for a sliding mode controller of buildings with ATMD [J].
Concha, Antonio ;
Thenozhi, Suresh ;
Betancourt, Ramon J. ;
Gadi, S. K. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 154
[5]   Tuned mass-damper-inerter control of wind-induced vibration of flexible structures based on inerter location [J].
Dai, Jun ;
Xu, Zhao-Dong ;
Gai, Pan-Pan .
ENGINEERING STRUCTURES, 2019, 199
[6]   Dynamic response and optimal design of structures with large mass ratio TMD [J].
De Angelis, Maurizio ;
Perno, Salvatore ;
Reggio, Anna .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (01) :41-60
[7]  
Den Hartog JP., 1985, MECH VIBRATIONS
[8]   Research developments in vibration control of structures using passive tuned mass dampers [J].
Elias, Said ;
Matsagar, Vasant .
ANNUAL REVIEWS IN CONTROL, 2017, 44 :129-156
[9]  
Frahm H., 1909, US Patent, Patent No. 989958
[10]   Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria [J].
Giaralis, A. ;
Taflanidis, A. A. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02)