Impact of marathon running on cardiac structure and function in recreational runners

被引:76
作者
Whyte, G
George, K
Shave, R
Dawson, E
Stephenson, C
Edwards, B
Gaze, D
Oxborough, D
Forster, J
Simspon, R
机构
[1] Northwick Pk Hosp & Clin Res Ctr, Olymp Med Inst, Harrow HA1 3UJ, Middx, England
[2] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Liverpool, Merseyside, England
[3] Brunel Univ, Dept Sport Sci, Uxbridge UB8 3PH, Middx, England
[4] Rigshosp, Dept Anaesthesia, Copenhagen, Denmark
[5] St George Hosp, Sch Med, Dept Chem Pathol, London SW17 0RE, England
[6] Nuffield Hosp, Dept Echocardiog, Leeds LS1 3EB, W Yorkshire, England
[7] Siemens Ltd, Bracknell RG12 8FZ, Berks, England
[8] Napier Univ, Dept Sports Sci, Edinburgh EH10 5DT, Midlothian, Scotland
关键词
cardiac troponin T; echocardiography; marathon; tissue Doppler imaging; reactive oxygen species;
D O I
10.1042/CS20040186
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The present study examined the relationship between LV (left ventricular) function, markers of cardiac-specific damage and markers of oxidative stress in recreational runners following a marathon. Runners (n = 52; 43 male and nine female; age, 35 +/- 10 years; height, 1.74 +/- 0.08 m; body mass, 75.9 +/- 8.9 kg) were assessed pre- and immediately post-marathon. LV function was assessed using standard M-mode two-dimensional Doppler echocardiography and TDI (tissue-Doppler imaging) echocardiography. Serum was analysed for cTnT (cardiac troponin-T), TEAC (Trolox equivalent antioxidant capacity; a measure of total antioxidant capacity), MDA (malondeal-dehyde) and 4-HNE (4-hydroxynonenal). A strong relationship was observed between standard and TDI echocardiography for all functional measures. Diastolic function was altered post-marathon characterized by a reduction in E (peak early diastolic filling. 0.79 +/- 0.11 compared with 0.64 +/- 0.16 cm/s; P < 0.001), an increase in A (peak late diastolic filling: 0.48 +/- 0.11 compared with 0.60 +/- 0.12 cm/s; P < 0.001) and a resultant decrease in E/A (ratio of E to A; 1.71 +/- 0.48 compared with 1.10 +/- 0.3 1; P < 0.001). Ejection fraction remained unchanged post-marathon. Thirty-two runners presented with cTnT values above the lower limit of detection for the assay (0.01 mug/l), and 20 runners presented post-marathon with cTnT values above the acute myocardial infarction cut-off value (0.05 mug/l). No significant correlations were observed between cTnT and any functional measurements. MDA (2.90 +/- 1.58 compared with 3.59 +/- 1.47 mumol/l) and TEAC (1.80 +/- 0.12 compared with 1.89 +/- 0.21 mmol/l) were significantly increased post-marathon, but were unrelated to changes in function or cTnT In conclusion, the present study demonstrated a reduction in diastolic function and widespread evidence of minimal cardiac damage following a marathon in recreational runners. The mechanism(s) underpinning the altered function and appearance of cTnT appear unrelated to reactive oxygen species.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 38 条
[1]   Characteristics of mitral and tricuspid annular velocities determined by pulsed wave Doppler tissue imaging in healthy subjects [J].
Alam, M ;
Wardell, J ;
Andersson, E ;
Samad, BA ;
Nordlander, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (08) :618-628
[2]   Raised cardiac troponins - Causes extend beyond acute coronary syndromes [J].
Ammann, P ;
Pfisterer, M ;
Fehr, T ;
Rickli, H .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 328 (7447) :1028-1029
[3]  
Apstein C S, 1998, Cardiologia, V43, P1269
[4]   Serum cardiac troponin T after repeated endurance exercise events [J].
Bonetti, A ;
Tirelli, F ;
Albertini, R ;
Monica, C ;
Monica, M ;
Tredici, G .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1996, 17 (04) :259-262
[5]   Elevated serum antioxidant capacity and plasma malondialdehyde concentration in response to a simulated half-marathon run [J].
Child, RB ;
Wilkinson, DM ;
Fallowfield, JL ;
Donnelly, AE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1998, 30 (11) :1603-1607
[6]   Are troponins confusing? [J].
Collinson, PO ;
Stubbs, PJ .
HEART, 2003, 89 (11) :1285-1287
[7]   Multicentre evaluation of the diagnostic value of cardiac troponin T, CK-MB mass, and myoglobin for assessing patients with suspected acute coronary syndromes in routine clinical practice [J].
Collinson, PO ;
Stubbs, PJ ;
Kessler, AC .
HEART, 2003, 89 (03) :280-286
[8]   Measurement of cardiac troponins [J].
Collinson, PO ;
Boa, FG ;
Gaze, DC .
ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 :423-449
[9]   COMPARISON OF SERUM CARDIAC SPECIFIC TROPONIN-I WITH CREATINE-KINASE, CREATINE KINASE-MB ISOENZYME, TROPOMYOSIN, MYOGLOBIN AND C-REACTIVE PROTEIN RELEASE IN MARATHON RUNNERS - CARDIAC OR SKELETAL-MUSCLE TRAUMA [J].
CUMMINS, P ;
YOUNG, A ;
AUCKLAND, ML ;
MICHIE, CA ;
STONE, PCW ;
SHEPSTONE, BJ .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1987, 17 (04) :317-324
[10]   Transient right but not left ventricular dysfunction after strenuous exercise at high altitude [J].
DavilaRoman, VG ;
Guest, TM ;
Tuteur, PG ;
Rowe, WJ ;
Ladenson, JH ;
Jaffe, AS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (02) :468-473