Target position reproducibility in left-breast irradiation with deep inspiration breath-hold using multiple optical surface control points

被引:18
|
作者
Fassi, Aurora [1 ]
Ivaldi, Giovanni B. [2 ]
de Fatis, Paola Tabarelli [3 ]
Liotta, Marco [3 ]
Meaglia, Ilaria [2 ]
Porcu, Patrizia [2 ]
Regolo, Lea [4 ]
Riboldi, Marco [1 ]
Baroni, Guido [1 ,5 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, Milan, Italy
[2] Ist Clin Sci Maugeri, Dept Radiat Oncol, Pavia, Italy
[3] Ist Clin Sci Maugeri, Div Med Phys, Pavia, Italy
[4] Ist Clin Sci Maugeri, Div Breast Surg, Pavia, Italy
[5] CNAO Fdn, Bioengn Unit, Clin Div, Pavia, Italy
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 04期
关键词
left-breast DIBH radiotherapy; optical tracking system; surface fiducials; target reproducibility; CANCER PATIENTS; RADIATION-THERAPY; RADIOTHERAPY; HEART; SYSTEM; MOTION; DIBH;
D O I
10.1002/acm2.12321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate the use of 3D optical localization of multiple surface control points for deep inspiration breath-hold (DIBH) guidance in left-breast radiotherapy treatments. Ten left-breast cancer patients underwent whole-breast DIBH radiotherapy controlled by the Real-time Position Management (RPM) system. The reproducibility of the tumor bed (i.e., target) was assessed by the position of implanted clips, acquired through in-room kV imaging. Six to eight passive fiducials were positioned on the patients' thoraco-abdominal surface and localized intrafractionally by means of an infrared 3D optical tracking system. The point-based registration between treatment and planning fiducials coordinates was applied to estimate the interfraction variations in patients' breathing baseline and to improve target reproducibility. The RPM-based DIBH control resulted in a 3D error in target reproducibility of 5.8 +/- 3.4 mm (median value +/- interquartile range) across all patients. The reproducibility errors proved correlated with the interfraction baseline variations, which reached 7.7 mm for the single patient. The contribution of surface fiducials registration allowed a statistically significant reduction (p<0.05) in target localization errors, measuring 3.4 +/- 1.7 mm in 3D. The 3D optical monitoring of multiple surface control points may help to optimize the use of the RPM system for improving target reproducibility in left-breast DIBH irradiation, providing insights on breathing baseline variations and increasing the robustness of external surrogates for DIBH guidance.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [11] Predictors of Cardiac Sparing in Deep Inspiration Breath-Hold for Patients With Left Sided Breast Cancer
    Mkanna, Abbas
    Mohamad, Osama
    Ramia, Paul
    Thebian, Ranim
    Makki, Maha
    Tamim, Hani
    Jalbout, Wassim
    Youssef, Bassem
    Eid, Toufic
    Geara, Fady
    Shahine, Bilal
    Zeidan, Youssef H.
    FRONTIERS IN ONCOLOGY, 2018, 8
  • [12] The cardiac dose-sparing benefits of deep inspiration breath-hold in left breast irradiation: a systematic review
    Smyth, Lloyd M.
    Knight, Kellie A.
    Aarons, Yolanda K.
    Wasiak, Jason
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (01) : 66 - 73
  • [13] Improving Intra-Fractional Target Position Accuracy Using a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique
    Rong, Yi
    Walston, Steve
    Welliver, Meng Xu
    Chakravarti, Arnab
    Quick, Allison M.
    PLOS ONE, 2014, 9 (05):
  • [14] Evaluation of target and cardiac position during visually monitored deep inspiration breath-hold for breast radiotherapy
    Conroy, Leigh
    Yeung, Rosanna
    Watt, Elizabeth
    Quirk, Sarah
    Long, Karen
    Hudson, Alana
    Tien Phan
    Smith, Wendy L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 25 - 36
  • [15] Target Correlation of a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique
    Rong, Y.
    Walston, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 562 - 562
  • [16] Comparison of setup accuracy of optical surface image versus orthogonal x-ray images for VMAT of the left breast using deep-inspiration breath-hold
    Lu, Wei
    Hong, Linda X.
    Yamada, Nelson
    Berry, Sean L.
    Song, Yulin
    Choi, Wookjin
    Cervino, Laura I.
    Tang, Xiaoli
    Mechalakos, James G.
    Romesser, Paul B.
    Powell, Simon
    Li, Guang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (12):
  • [17] Selection criteria and method for deep inspiration breath-hold in patients with left breast cancer undergoing PMRT/IMRT
    Zhou, Yingying
    Xu, Jinfeng
    Xu, Fumin
    Li, Yanning
    Li, Huali
    Pan, Lisheng
    Li, Yang
    Cao, Shuyi
    Cai, Longmei
    Yang, Lin
    Chen, Bo
    Wang, Hongmei
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 48
  • [18] Left-sided Breast Cancer Irradiation With Deep Inspiration Breath-hold: Changes in Heart and Lung Dose in Two Periods
    Knoechelmann, Anne Caroline
    Ceylan, Nese
    Bremer, Michael
    IN VIVO, 2022, 36 (01): : 314 - 324
  • [19] Deep inspiration breath-hold (DIBH) radiotherapy in left-sided breast cancer
    Hepp, Rodrigo
    Ammerpohl, Mark
    Morgenstern, Christina
    Nielinger, Lisa
    Erichsen, Patricia
    Abdallah, Abdallah
    Galalae, Razvan
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (09) : 710 - 716
  • [20] Geometrical uncertainty of heart position in deep-inspiration breath-hold radiotherapy of left-sided breast cancer patients
    Koivumaki, Tuomas
    Tujunen, Juuso
    Viren, Tuomas
    Heikkila, Janne
    Seppala, Jan
    ACTA ONCOLOGICA, 2017, 56 (06) : 879 - 883