Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams

被引:12
|
作者
Karaj, E. [1 ]
Righi, S. [1 ]
Di Martino, F. [1 ]
机构
[1] Azienda Osped Univ Pisana, UO Fis Sanitaria, I-56126 Pisa, Italy
关键词
IORT; dose per pulse; k(sat); inclined applicators; small cylindrical ionization chamber;
D O I
10.1118/1.2436979
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Very high dose per pulse (3-13 cGy/pulse) high energy electron beams are currently produced by special linear accelerators (linac) dedicated to Intra Operative Radiation Therapy (IORT). The electron beams produced by such linacs are collimated by special Perspex applicators of various size and cylindrically shaped. The biggest problems from the dosimetric point of view are caused by the high dose-per-pulse values and the use of inclined applicators. In this work measurements of absolute dose for the inclined applicators were done by using a small cylindrical ionization chamber, type CC01 (Wellhofer), a parallel plane ionization chamber type Markus (PTW 23343) and radiochromic films type EBT. We show a method which allows calculating the quality correction factors for CC01 chamber with an uncertainty of 1% and the absolute dose value for the inclined applicators using CC01 with an uncertainty of 3.1% for electron beams of energy of 6 and 7 MeV produced by the linac dedicated to IORT Novac7. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:952 / 958
页数:7
相关论文
共 50 条
  • [21] The challenge of ionisation chamber dosimetry in ultra-short pulsed high dose-rate Very High Energy Electron beams
    M. McManus
    F. Romano
    N. D. Lee
    W. Farabolini
    A. Gilardi
    G. Royle
    H. Palmans
    A. Subiel
    Scientific Reports, 10
  • [22] COMPARISON OF ABSORBED DOSE MEASUREMENTS WITH AN EXTRAPOLATION CHAMBER AND A FARMER CHAMBER IN HIGH ENERGY ELECTRON BEAM
    S.C.Klevenhagen
    靳涛
    王密
    吴进争
    孙强生
    NuclearScienceandTechniques, 1990, (04) : 249 - 253
  • [23] Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
    Dasu, A
    Lofroth, PO
    Wickman, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01): : 21 - 36
  • [24] Focused VHEE (very high energy electron) beams and dose delivery for radiotherapy applications
    Whitmore, L.
    Mackay, R., I
    van Herk, M.
    Jones, J. K.
    Jones, R. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [25] Focused VHEE (very high energy electron) beams and dose delivery for radiotherapy applications
    L. Whitmore
    R. I. Mackay
    M. van Herk
    J. K. Jones
    R. M. Jones
    Scientific Reports, 11
  • [26] The PTB water calorimeter for determining the absolute absorbed dose to water in ultra-high pulse dose rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [27] Absolute dose determination in high-energy electron beams: Comparison of IAEA dosimetry protocols
    Sathiyan, S.
    Ravikumar, M.
    JOURNAL OF MEDICAL PHYSICS, 2008, 33 (03) : 108 - 113
  • [28] USE OF A SMALL, CYLINDRICAL PARALLEL PLATE (PANCAKE TYPE) IONIZATION CHAMBER TO CALIBRATE HIGH ENERGY X-RAY AND ELECTRON BEAMS
    HOLT, JG
    EDELSTEI.GR
    LAUGHLIN, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 134 - &
  • [29] Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose
    Gotz, M.
    Karsch, L.
    Pawelke, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3316 - 3316
  • [30] Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy
    Di Venanzio, C.
    Marinelli, Marco
    Tonnetti, A.
    Verona-Rinati, G.
    Falco, M. D.
    Pimpinella, M.
    Ciccotelli, A.
    De Stefano, S.
    Felici, G.
    Marangoni, F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 897 - 902