Using edge-preserving algorithm with non-local mean for significantly improved image-domain material decomposition in dual-energy CT

被引:43
作者
Zhao, Wei [1 ]
Niu, Tianye [2 ]
Xing, Lei [3 ]
Xie, Yaoqin [4 ]
Xiong, Guanglei [5 ,6 ]
Elmore, Kimberly [5 ,6 ]
Zhu, Jun [1 ]
Wang, Luyao [1 ]
Min, James K. [5 ,6 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Biomed Engn, Hubei 430074, Peoples R China
[2] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Inst Translat Med, Hangzhou 310016, Zhejiang, Peoples R China
[3] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[5] New York Presbyterian Hosp, Dalio Inst Cardiovasc Imaging, New York, NY 10021 USA
[6] Weill Cornell Med Coll, New York, NY 10021 USA
关键词
dual-energy CT; material decomposition; non-local mean; iterative image-domain decomposition; HYPR; ITERATIVE RECONSTRUCTION; IODINE QUANTIFICATION; NOISE SUPPRESSION; TOMOGRAPHY; REDUCTION; ART;
D O I
10.1088/0031-9155/61/3/1332
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Increased noise is a general concern for dual-energy material decomposition. Here, we develop an image-domain material decomposition algorithm for dual-energy CT (DECT) by incorporating an edge-preserving filter into the Local HighlY constrained backPRojection reconstruction (HYPR-LR) framework. With effective use of the non-local mean, the proposed algorithm, which is referred to as HYPR-NLM, reduces the noise in dual-energy decomposition while preserving the accuracy of quantitative measurement and spatial resolution of the material-specific dual-energy images. We demonstrate the noise reduction and resolution preservation of the algorithm with an iodine concentrate numerical phantom by comparing the HYPR-NLM algorithm to the direct matrix inversion, HYPR-LR and iterative image-domain material decomposition (Iter-DECT). We also show the superior performance of the HYPR-NLM over the existing methods by using two sets of cardiac perfusing imaging data. The DECT material decomposition comparison study shows that all four algorithms yield acceptable quantitative measurements of iodine concentrate. Direct matrix inversion yields the highest noise level, followed by HYPR-LR and Iter-DECT. HYPR-NLM in an iterative formulation significantly reduces image noise and the image noise is comparable to or even lower than that generated using Iter-DECT. For the HYPR-NLM method, there are marginal edge effects in the difference image, suggesting the high-frequency details are well preserved. In addition, when the search window size increases from 11 x 11 to 19 x 19, there are no significant changes or marginal edge effects in the HYPR-NLM difference images. The reference drawn from the comparison study includes: (1) HYPR-NLM significantly reduces the DECT material decomposition noise while preserving quantitative measurements and high-frequency edge information, and (2) HYPR-NLM is robust with respect to parameter selection.
引用
收藏
页码:1332 / 1351
页数:20
相关论文
共 59 条
  • [11] Dynamic PET Denoising with HYPR Processing
    Christian, Bradley T.
    Vandehey, Nicholas T.
    Floberg, John M.
    Mistretta, Charles A.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (07) : 1147 - 1154
  • [12] Alternating Direction Method of Multiplier for Tomography With Nonlocal Regularizers
    Chun, Se Young
    Dewaraja, Yuni K.
    Fessler, Jeffrey A.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (10) : 1960 - 1968
  • [13] Spectral diffusion: an algorithm for robust material decomposition of spectral CT data
    Clark, Darin P.
    Badea, Cristian T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21) : 6445 - 6466
  • [14] Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization
    Dong, Xue
    Niu, Tianye
    Zhua, Lei
    [J]. MEDICAL PHYSICS, 2014, 41 (05)
  • [15] Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study
    Faby, Sebastian
    Kuchenbecker, Stefan
    Sawall, Stefan
    Simons, David
    Schlemmer, Heinz-Peter
    Lell, Michael
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2015, 42 (07) : 4349 - 4366
  • [16] Quantification of Liver Fat in the Presence of Iron and Iodine An Ex-Vivo Dual-Energy CT Study
    Fischer, Michael A.
    Gnannt, Ralph
    Raptis, Dimitri
    Reiner, Caecilia S.
    Clavien, Pierre-Alain
    Schmidt, Bernhard
    Leschka, Sebastian
    Alkadhi, Hatem
    Goetti, Robert
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (06) : 351 - 358
  • [17] Dual energy CT: preliminary observations and potential clinical applications in the abdomen
    Graser, Anno
    Johnson, Thorsten R. C.
    Chandarana, Hersh
    Macari, Michael
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (01) : 13 - 23
  • [18] A novel image optimization method for dual-energy computed tomography
    Hao, Jia
    Kang, Kejun
    Zhang, Li
    Chen, Zhiqiang
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 722 : 34 - 42
  • [19] Applications of Dual-Energy CT in Urologic Imaging: An Update
    Hartman, Robert
    Kawashima, Akira
    Takahashi, Naoki
    Silva, Alvin
    Vrtiska, Terri
    Leng, Shuai
    Fletcher, Joel
    McCollough, Cynthia
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2012, 50 (02) : 191 - +
  • [20] Improved waveform fidelity using local HYPR reconstruction (HYPR LR)
    Johnson, Kevin M.
    Velikina, Julia
    Wu, Yijing
    Kecskemeti, Steve
    Wieben, Oliver
    Mistretta, Charles A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 456 - 462