Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources

被引:21
作者
Arroyo, Maira Gazzola [1 ]
Ferreira, Adriano Menis [2 ,3 ]
Frota, Oleci Pereira [2 ,3 ]
Rigotti, Marcelo Alessandro [4 ]
de Andrade, Denise [5 ]
Brizzotti, Natalia Seron [6 ]
Macruz Peresi, Jacqueline Tanury [7 ]
Castilho, Elza Maria [6 ]
Gottardo de Almeida, Margarete Teresa [6 ]
机构
[1] Sao Paulo State Univ, Grad Program Microbiol, St Cristovao Colombo 2265, BR-15054000 Sao Jose Do Rio Preto, SP, Brazil
[2] Univ Fed Mato Grosso do Sul, Master & Doctoral Grad Program Hlth & Dev West Ce, Av Costa & Silva,S-N 79070-900, Campo Grande, Mato Grosso Do, Brazil
[3] Univ Fed Mato Grosso do Sul, Master Grad Program Nursing, Av Costa & Silva,S-N 79070-900, Campo Grande, Mato Grosso Do, Brazil
[4] Univ Fed Mato Grosso do Sul, Undergrad Program Nursing, Av Ranulpho Marques Leal 3484, BR-79610100 Tres Lagoas, Mato Grosso Do, Brazil
[5] Univ Sao Paulo, Ribeirao Preto Coll Nursing, Dept Gen & Specialized Nursing, WHO Collaborating Ctr Nursing Res Dev, Av Bandeirantes 3900, BR-14040902 Ribeirao Preto, SP, Brazil
[6] Fac Med Sao Jose do Rio Preto, Dept Infect & Parasit Dis, Av Brg Faria Lima 5416, BR-15090000 Sao Jose Do Rio Preto, SP, Brazil
[7] Adolfo Lutz Inst, Ctr Reg Lab Sao Jose do Rio Preto, St Rua Alberto Sufredini Bertoni 2325, BR-15060020 Sao Jose Do Rio Preto, SP, Brazil
关键词
Adenosine triphosphate; Bacteria; Fungi; Hospital; Water; ADENOSINE-TRIPHOSPHATE BIOLUMINESCENCE; DRINKING-WATER; BACTERIA; SURFACES; COUNTS; CARBON; MARKER;
D O I
10.1186/s12879-017-2562-y
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Laboratory analysis of organisms in water include arduous methods, such as the multiple tube and membrane filter. The ATP bioluminescence system, proposes a new way of measuring cellular material in water by measuring adenosine triphosphate (ATP) levels, which are expressed in relative light units (RLU). The ATP bioluminescence assay has been increasingly used to assess the microbiological safety of the hospital environment. However, there are few studies investigating the use of this methodology to evaluate the microbiological quality of water. The objective of the present study was to verify whether ATP, as measured by the 3 M (TM) Clean-Trace Water (TM) ATP test, can be used as an alternative tool for presumptive testing for the presence of microorganisms in hospital water. Methods: Water samples (N = 88) were collected from faucets (74) and water purifiers (14) in a university hospital. The sample were filtered by the membrane filter technique (100 mL for bacterial analysis and 100 mL for fungal analysis) and then submitted to ATP bioluminescence assay to the determine quantity of RLU in each sample. In order to compare RLU and the presence of microorganisms, a receiver operating characteristic (ROC) curve was used to calculate sensitivity and specificity (levels higher than 90% were considered significant). In addition, control tests were conducted to compare RLU to the quantities of bacterial and fungal organisms added to distilled water (ANOVA and Tukey's tests; p <= 0.05). This inoculum was compared to RLU emission, and the data were analyzed by calculating the Pearson's correlation coefficient, with a 95% confidence interval. Results: In the present study, 94.3% of the water samples presented bacterial growth. Of these, 15.6% showed heterotrophic bacteria above recommended levels and fungal contamination was detected in 55.6% of samples. Sensitivity and specificity of the samples were not significant (<90%), and the correlation between ATP and the presence of these microorganisms in the samples (hospital water) was not significant, whereas, in distilled water, the results revealed a significant difference (p < 0.0001). Conclusions: These results demonstrated that the ATP test cannot be used as an alternative tool for presumptive assessment of the presence of microorganisms in water.
引用
收藏
页数:5
相关论文
共 23 条
[1]  
Adetunde LA, 2011, PRIME J MICROBIOL RE, V1, P47
[2]   Comparison of Fluorescent Marker Systems with 2 Quantitative Methods of Assessing Terminal Cleaning Practices [J].
Boyce, John M. ;
Havill, Nancy L. ;
Havill, Heather L. ;
Mangione, Elise ;
Dumigan, Diane G. ;
Moore, Brent A. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (12) :1187-1193
[3]   Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay [J].
Boyce, John M. ;
Havill, Nancy L. ;
Dumigan, Diane G. ;
Golebiewski, Michael ;
Balogun, Ola ;
Rizvani, Ramo .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (07) :678-684
[4]  
Brazilian Ministry of Health, 2011, PROT POT WAT HUM CON
[5]   Comparison of immunomagnedic separation/adenosine triphosphate rapid method to traditional culture-based method for E. coli and enterococci enumeration in wastewater [J].
Bushon, Rebecca N. ;
Likirdopulos, Christina A. ;
Brady, Amie M. G. .
WATER RESEARCH, 2009, 43 (19) :4940-4946
[6]   Lack of correlation between Legionella colonization and microbial population quantification using heterotrophic plate count and adenosine triphosphate bioluminescence measurement [J].
Duda, Scott ;
Baron, Julianne L. ;
Wagener, Marilyn M. ;
Vidic, Radisav D. ;
Stout, Janet E. .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2015, 187 (07)
[7]   LIMITATIONS OF ATP ESTIMATES OF MICROBIAL BIOMASS [J].
FAIRBANKS, BC ;
WOODS, LE ;
BRYANT, RJ ;
ELLIOTT, ET ;
COLE, CV ;
COLEMAN, DC .
SOIL BIOLOGY & BIOCHEMISTRY, 1984, 16 (06) :549-558
[8]   Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes [J].
Hammes, Frederik ;
Berney, Michael ;
Wang, Yingying ;
Vital, Marius ;
Koester, Oliver ;
Egli, Thomas .
WATER RESEARCH, 2008, 42 (1-2) :269-277
[9]   Measurement and interpretation of microbial adenosine tri-phosphate (ATP) in aquatic environments [J].
Hammes, Frederik ;
Goldschmidt, Felix ;
Vital, Marius ;
Wang, Yingying ;
Egli, Thomas .
WATER RESEARCH, 2010, 44 (13) :3915-3923
[10]  
Hoog GSD., 2000, ATLAS CLIN FUNGI ULT, V2