Gum elastic bougie-guided insertion of the ProSeal™ laryngeal mask airway

被引:25
作者
Brimacombe, J
Keller, C
机构
[1] Cairns Base Hosp, Dept Anaesthesia & Intens Care, Cairns, Qld 4870, Australia
[2] Leopold Franzens Univ, Dept Anaesthesia & Intens Care Med, Innsbruck, Austria
关键词
equipment; laryngeal mask airway; gum elastic bougie; insertion;
D O I
10.1177/0310057X0403200514
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We tested the hypothesis that gum elastic-bougie-guided insertion of the ProSeal(TM) Laryngeal Mask Airway is more frequently successful than introducer tool guided insertion after failed digital insertion. One hundred anaesthetized patients (ASA 1-2, aged 18 to 80 years) were randomized for the second insertion attempt using either the gum elastic bougie-guided or introducer tool techniques. The bougie-guided technique involved priming the drain tube with the bougie, placing the bougie in the oesophagus using laryngoscope guidance, digital insertion along the palatopharyngeal curve, and bougie removal. The introducer tool technique involved attaching the introducer tool, single-handed rotation along the palatopharyngeal curve, and introducer tool removal. Failed insertion was classified as (i) failed passage into the pharynx, (ii) malposition, or (iii) ineffective ventilation. Any blood staining was documented. Insertion was more frequently successful (50/50 vs 15/50, P=0.0002) and faster (35+/-17s vs 54+/-45s, mean+/-SD, P=0.006) with the bougie-guided technique. All failed insertions with the introducer tool technique were successful with the bougie-guided technique. The aetiology of failed insertion was similar for the digital and introducer tool techniques in 94% (33/35) of patients. There was no blood staining on the bougie, laryngoscope or introducer tool at removal, but blood staining was more common on the Proseal laryngeal mask airway with the introducer tool technique (9/50 vs 2/50, P=0.03). We conclude that the gum elastic bougie-guided insertion has a higher success rate and causes less trauma than the insertion tool insertion technique after failed digital insertion of the Proseal Laryngeal Mask Airway.
引用
收藏
页码:681 / 684
页数:4
相关论文
共 21 条
[1]   Laryngeal mask airway and the ASA difficult airway algorithm [J].
Benumof, JL .
ANESTHESIOLOGY, 1996, 84 (03) :686-699
[2]   The LMA 'ProSeal' - a laryngeal mask with an oesophageal vent [J].
Brain, AIJ ;
Verghese, C ;
Strube, PJ .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (05) :650-654
[3]   The ProSeal laryngeal mask airway - A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients [J].
Brimacombe, J ;
Keller, C .
ANESTHESIOLOGY, 2000, 93 (01) :104-109
[4]   Gum elastic Bongie-guided insetfion of the ProSeal™ laryngeal mask airway is superior to the digital and introducer tool techniques [J].
Brimacombe, J ;
Keller, C ;
Judd, DV .
ANESTHESIOLOGY, 2004, 100 (01) :25-29
[5]   A multicenter study comparing the ProSeal™ and Classic™ laryngeal mask airway in anesthetized, nonparalyzed patients [J].
Brimacombe, J ;
Keller, C ;
Fullekrug, B ;
Agrò, F ;
Rosenblatt, W ;
Dierdorf, SF ;
de Lucas, EG ;
Capdevilla, X ;
Brimacombe, N .
ANESTHESIOLOGY, 2002, 96 (02) :289-295
[6]   Stability of the LMA-ProSeal® and standard laryngeal mask airway in different head and neck positions:: a randomized crossover study [J].
Brimacombe, J ;
Keller, C .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2003, 20 (01) :65-69
[7]   A comparison of the laryngeal mask airway ProSealTM and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation [J].
Brimacombe, J ;
Keller, C ;
Brimacombe, L .
ANESTHESIA AND ANALGESIA, 2002, 95 (03) :770-776
[8]   Awake fibreoptic-guided insertion of the ProSeal Laryngeal Mask Airway™ [J].
Brimacombe, J ;
Keller, C .
ANAESTHESIA, 2002, 57 (07) :719-719
[9]   Positive pressure ventilation with the ProSeal versus classic laryngeal mask airway:: A randomized, crossover study of healthy female patients [J].
Brimacombe, J ;
Keller, C ;
Boehler, M ;
Pühringer, F .
ANESTHESIA AND ANALGESIA, 2001, 93 (05) :1351-1353
[10]  
Brimacombe J, 2001, ANESTH ANALG, V92, P1614