Voltammetric determination of dopamine in human serum with amphiphilic chitosan modified glassy carbon electrode

被引:20
作者
Wang, Cheng Yin [1 ]
Wang, Zhi Xian [1 ]
Zhu, Ai Ping [1 ]
Hu, Xiao Ya [1 ]
机构
[1] Yangzhou Univ, Dept Chem & Chem Engn, Yangzhou 225002, Peoples R China
关键词
o-carboxymethylchitosan; chitosan; dopamine; voltammetry; human serum;
D O I
10.3390/s6111523
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improvement of selectivity for electrochemical detection of dopamine ( DA) with differential pulse voltammetry is achieved by covalently modifying a glassy carbon electrode ( GCE) with O-carboxymethylchitosan ( OCMCS). The amphiphilic chitosan provides electrostatic accumulation of DA onto the electrode surface. In a phosphate buffer solution ( pH 6.0), a pair of well-defined reversible redox waves of DA was observed at the OCMCS/GCE with a Delta E-p of 52 mV. The anodic peak current obtained from the differential pulse voltammetry of dopamine was linearly dependent on its concentration in the range of 6.0 x 10(-8) to 7.0 x 10(-6) M, with a correlation coefficient of 0.998. The detection limit ( S/N = 3) was found to be 1.5 x 10(-9) M. The modified electrode had been applied to the determination of DA in human serum samples with satisfactory results.
引用
收藏
页码:1523 / 1536
页数:14
相关论文
共 50 条
[31]   Electrocatalysis and voltammetric determination of dopamine at a calix[4]arene crown-4 ether modified glassy carbon electrode [J].
Lai, Guo-Song ;
Zhang, Hai-Li ;
Jin, Chuan-Ming .
ELECTROANALYSIS, 2007, 19 (04) :496-501
[32]   Simultaneous voltammetric determination of acetaminophen and dopamine using a glassy carbon electrode modified with copper porphyrin-exfoliated graphene [J].
Xinjian Song ;
Ju Fu ;
Juan Wang ;
Chunya Li ;
Zhihong Liu .
Microchimica Acta, 2018, 185
[33]   Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode [J].
Ghorbani-Bidkorbeh, Fatemeh ;
Shahrokhian, Saeed ;
Mohammadi, Ali ;
Dinarvand, Rassoul .
ELECTROCHIMICA ACTA, 2010, 55 (08) :2752-2759
[34]   Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide [J].
Lisnund, Sireerat ;
Blay, Vincent ;
Chansaenpak, Kantapat ;
Pinyou, Piyanut .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08) :7214-7227
[35]   Voltammetric Determination of Chili Peppers Pungency using Phospholipid Modified Glassy Carbon Electrode [J].
Skopalova, Jana ;
Rajcova, Andrea ;
Vokounova, Sarka ;
Navratil, Tomas .
PROCEEDINGS OF INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXIX, 2019, :188-192
[36]   APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL [J].
Piech, Robert ;
Paczosa-Bator, Beata .
ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06) :1081-1088
[37]   Voltammetric determination of mitomycin C using a chemically-modified glassy carbon electrode [J].
Qu, WY ;
Wang, H ;
Wu, HB .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2005, 70 (02) :178-187
[38]   High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs [J].
Piech, Robert ;
Rumin, Martyna ;
Paczosa-Bator, Beata .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12) :7528-7539
[39]   Amperometric determination of dopamine on a glassy carbon electrode chemically modified with cobalt pentacyanonitrosylferrate [J].
Bari, Mahmoud Rezazadeh ;
Sabzi, Reza Emamali .
ASIAN JOURNAL OF CHEMISTRY, 2008, 20 (05) :3357-3363
[40]   VOLTAMMETRIC DETERMINATION OF ROPINIROLE AT GLASSY CARBON ELECTRODE EMPLOYING PULSED TECHNIQUES [J].
Bozal-Palabiyik, Burcin ;
Uslu, Bengi .
REVUE ROUMAINE DE CHIMIE, 2017, 62 (6-7) :559-567