Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up

被引:24
|
作者
Bedard, Nicholas A. [1 ]
Callaghan, John J. [1 ,2 ]
Stefl, Michael D. [3 ]
Willman, Tyler J. [1 ]
Liu, Steve S. [1 ]
Goetz, Devon D. [4 ]
机构
[1] Univ Iowa, Iowa City, IA USA
[2] VA Med Ctr, Iowa City, IA USA
[3] Univ So Calif, Los Angeles, CA USA
[4] Des Moines Orthopaed Surg, W Des Moines, IA USA
关键词
cementless acetabular component; wear; cross-linked polyethylene; outcomes; activity level; TOTAL HIP-ARTHROPLASTY; FEMORAL COMPONENTS; PATIENTS YOUNGER; REPLACEMENT; THA; CHARNLEY; CEMENT; OSTEOARTHRITIS; STEM; AGE;
D O I
10.1016/j.arth.2014.05.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10 year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04 mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner. Level of evidence: Therapeutic study, Level III (retrospective comparative study-prospective cohort with historical control). (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1961 / 1969
页数:9
相关论文
共 50 条
  • [41] A randomised controlled trial comparing highly cross-linked and contemporary annealed polyethylene after a minimal eight-year follow-up in total hip arthroplasty using cemented acetabular components
    Langlois, J.
    Atlan, F.
    Scemama, C.
    Courpied, J. P.
    Hamadouche, M.
    BONE & JOINT JOURNAL, 2015, 97B (11) : 1458 - 1462
  • [42] Primary Cementless Acetabular Fixation at a Minimum of Twenty Years of Follow-up A Concise Update of a Previous Report
    Stefl, Michael D.
    Callaghan, John J.
    Liu, Steve S.
    Pedersen, Douglas R.
    Goetz, Devon D.
    Johnston, Richard C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (03) : 234 - 239
  • [43] In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up
    Hasegawa, Masahiro
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [44] Comparison of 10-year clinical wear of annealed and remelted highly cross-linked polyethylene: A propensity-matched cohort study
    Hamai, Satoshi
    Nakashima, Yasuharu
    Mashima, Naohiko
    Yamamoto, Takuaki
    Kamada, Tomomi
    Motomura, Goro
    Imai, Hiroshi
    Fukushi, Jun-ichi
    Miura, Hiromasa
    Iwamoto, Yukihide
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 59 : 99 - 107
  • [45] Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty With a 32-mm Cobalt-Chromium Head on Highly Cross-Linked Polyethylene and a Tapered, Fiber Metal Proximally Coated Femoral Stem
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    JOURNAL OF ARTHROPLASTY, 2021, 36 (02) : 647 - 652
  • [46] Cemented Polished Tapered Stems in Patients Less Than 50 Years of Age: A Minimum 10-year Follow-Up
    Burston, Ben J.
    Yates, Piers J.
    Hook, Samantha
    Moulder, Elizabeth
    Whitley, Elise
    Bannister, Gordon C.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (05) : 692 - 699
  • [47] Higher offset cross-linked polyethylene acetabular liners: is wear a significant clinical concern?
    Chapman, Ryan M.
    Van Citters, Douglas W.
    Chapman, Danielle
    Dalury, David F.
    HIP INTERNATIONAL, 2019, 29 (06) : 652 - 659
  • [48] Ceramic-on-ceramic vs ceramic-on-polyethylene, a comparative study with 10-year follow-up
    van Loon, Justin
    Hoornenborg, Daniel
    van der Vis, Harm M.
    Sierevelt, Inger N.
    Opdam, Kim T. M.
    Kerkhoffs, Gino M. M. J.
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2021, 12 (01): : 14 - 23
  • [49] Highly Cross-Linked Versus Conventional Polyethylene in Posterior-Stabilized Total Knee Arthroplasty at a Mean 5-Year Follow-up
    Meneghini, R. Michael
    Lovro, Luke R.
    Smits, Shelly A.
    Ireland, Philip H.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10) : 1736 - 1739
  • [50] Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results
    Regis, Dario
    Sandri, Andrea
    Bonetti, Ingrid
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014