Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up

被引:24
|
作者
Bedard, Nicholas A. [1 ]
Callaghan, John J. [1 ,2 ]
Stefl, Michael D. [3 ]
Willman, Tyler J. [1 ]
Liu, Steve S. [1 ]
Goetz, Devon D. [4 ]
机构
[1] Univ Iowa, Iowa City, IA USA
[2] VA Med Ctr, Iowa City, IA USA
[3] Univ So Calif, Los Angeles, CA USA
[4] Des Moines Orthopaed Surg, W Des Moines, IA USA
关键词
cementless acetabular component; wear; cross-linked polyethylene; outcomes; activity level; TOTAL HIP-ARTHROPLASTY; FEMORAL COMPONENTS; PATIENTS YOUNGER; REPLACEMENT; THA; CHARNLEY; CEMENT; OSTEOARTHRITIS; STEM; AGE;
D O I
10.1016/j.arth.2014.05.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10 year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04 mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner. Level of evidence: Therapeutic study, Level III (retrospective comparative study-prospective cohort with historical control). (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1961 / 1969
页数:9
相关论文
共 50 条
  • [31] Up to 18-Year Follow-Up Wear Analysis of a First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Feng, James E.
    Novikov, David
    Chen, Kevin
    Kim, Kelvin
    Bookman, Jared
    Anoushiravani, Afshin A.
    Hamula, Matthew
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10) : 3325 - 3328
  • [32] Significantly Lower Wear of Ceramic-on-Ceramic Bearings Than Metal-on-Highly Cross-Linked Polyethylene Bearings: A 10-to 14-Year Follow-Up Study
    Higuchi, Yoshitoshi
    Hasegawa, Yukiharu
    Seki, Taisuke
    Komatsu, Daigo
    Ishiguro, Naoki
    JOURNAL OF ARTHROPLASTY, 2016, 31 (06) : 1246 - 1250
  • [33] Large Femoral Heads With Small Acetabular Components: An Examination of 10-Year Polyethylene Wear
    Thalody, Hope S.
    Ponzio, Danielle Y.
    Santoro, Adam J.
    Radack, Tyler M.
    Post, Zachary D.
    Ong, Alvin C.
    ORTHOPEDICS, 2023, 47 (02) : 118 - 122
  • [34] Ten-to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?
    Cheung, Amy
    Yan, Chun Hoi
    Fu, Henry
    Cheung, Man Hong
    Chan, Ping Keung
    Chiu, Kwong Yuen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09) : 2016 - 2021
  • [35] Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study
    Nicholas D. Clement
    Martin Mitchell
    Morag E. Trayner
    Daniel E. Porter
    Graham M. Lawson
    Richard Burnett
    International Orthopaedics, 2013, 37 : 2337 - 2343
  • [36] Custom Triflange Acetabular Implants: Average 10-Year Follow-Up
    Meding, John B.
    Meding, Lindsey K.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07) : S201 - S205
  • [37] Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up
    Gaudiani, Michael A.
    White, Peter B.
    Ghazi, Narges
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 590 - 594
  • [38] Femoral-Acetabular Mating: The Effect of Femoral and Combined Anteversion on Cross-Linked Polyethylene Wear
    Mayeda, Brian F.
    Haw, Jonathan G.
    Battenberg, Andrew K.
    Schmalzried, Thomas P.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10) : 3320 - 3324
  • [39] Hip Squeaking A 10-Year Follow-Up Study
    Chevillotte, Christophe
    Pibarot, Vincent
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1008 - 1013
  • [40] Total Wrist Arthroplasty: A 10-Year Follow-Up
    Fischer, Per
    Sagerfors, Marcus
    Jakobsson, Hugo
    Pettersson, Kurt
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (08): : 780.e1 - 780.e10