Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up

被引:24
|
作者
Bedard, Nicholas A. [1 ]
Callaghan, John J. [1 ,2 ]
Stefl, Michael D. [3 ]
Willman, Tyler J. [1 ]
Liu, Steve S. [1 ]
Goetz, Devon D. [4 ]
机构
[1] Univ Iowa, Iowa City, IA USA
[2] VA Med Ctr, Iowa City, IA USA
[3] Univ So Calif, Los Angeles, CA USA
[4] Des Moines Orthopaed Surg, W Des Moines, IA USA
关键词
cementless acetabular component; wear; cross-linked polyethylene; outcomes; activity level; TOTAL HIP-ARTHROPLASTY; FEMORAL COMPONENTS; PATIENTS YOUNGER; REPLACEMENT; THA; CHARNLEY; CEMENT; OSTEOARTHRITIS; STEM; AGE;
D O I
10.1016/j.arth.2014.05.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10 year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04 mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner. Level of evidence: Therapeutic study, Level III (retrospective comparative study-prospective cohort with historical control). (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1961 / 1969
页数:9
相关论文
共 50 条
  • [21] Wear analysis of the first-generation cross-linked polyethylene at minimum 10 years follow-up after THA: no significant effect of sports participation
    Harada, Satoru
    Hamai, Satoshi
    Shiomoto, Kyohei
    Hara, Daisuke
    Motomura, Goro
    Ikemura, Satoshi
    Fujii, Masanori
    Nakashima, Yasuharu
    JOURNAL OF ARTIFICIAL ORGANS, 2022, 25 (02) : 140 - 147
  • [22] Wear of highly cross-linked polyethylene acetabular cup in Japan
    Oonishi, Hironobu
    Kim, Sok Chol
    Takao, Yasuhiro
    Kyomoto, Masayuki
    Iwamoto, Mikio
    Ueno, Masaru
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07) : 944 - 949
  • [23] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty in Patients Younger Than 50 Years With Osteonecrosis of the Femoral Head: A Minimum of 10 Years of Follow-Up
    Min, Byung-Woo
    Cho, Chul-Hyun
    Son, Eun-Suck
    Lee, Kyung-Jae
    Lee, Si-Wook
    Song, Kwang-Soon
    JOURNAL OF ARTHROPLASTY, 2020, 35 (03) : 805 - 810
  • [24] Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study
    Clement, Nicholas D.
    Mitchell, Martin
    Trayner, Morag E.
    Porter, Daniel E.
    Lawson, Graham M.
    Burnett, Richard
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2337 - 2343
  • [25] Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty in Patients with Previous Acetabular Fractures: A Minimum 5-Year Follow-Up Study
    Byung-Woo Min
    Ki-Cheor Bae
    Chul-Hyun Cho
    Eun-Suck Son
    Kyung-Jae Lee
    Si-Wook Lee
    Indian Journal of Orthopaedics, 2020, 54 : 239 - 245
  • [26] Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Clinical and Radiographic Outcomes in Total Knee Arthroplasty at 10-Year Follow-up
    Remily, Ethan A.
    Wilkie, Wayne A.
    Mohamed, Nequesha S.
    Smith, Langan S.
    Malkani, Arthur L.
    Jaggard, Charles E.
    Kolisek, Frank R.
    Monesmith, Eric A.
    Nace, James
    Delanois, Ronald E.
    ORTHOPEDICS, 2023, 46 (02) : 113 - 117
  • [27] Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up
    Giustra, Fortunato
    Bistolfi, Alessandro
    Bosco, Francesco
    Fresia, Nicolo
    Sabatini, Luigi
    Berchialla, Paola
    Sciannameo, Veronica
    Masse, Alessandro
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1082 - 1088
  • [28] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Sadri, Hassan
    Pfander, Gregoire
    Siebenrock, Klaus-Arno
    Tannast, Moritz
    Koch, Peter
    Fujita, Hiroshi
    Ballmer, Peter
    Ganz, Reinhold
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (08) : 869 - 877
  • [29] Acetabular reinforcement ring in primary total hip arthroplasty: a minimum 10-year follow-up
    Hassan Sadri
    Grégoire Pfander
    Klaus-Arno Siebenrock
    Moritz Tannast
    Peter Koch
    Hiroshi Fujita
    Peter Ballmer
    Reinhold Ganz
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 869 - 877
  • [30] No Revisions Attributable to Wear of Highly Cross-Linked Polyethylene Liners: A Long-Term Follow-Up Study
    Wright, Breydan H.
    Hadley, Matthew L.
    Harmer, Joshua R.
    Fruth, Kristin M.
    Sierra, Rafael J.
    Couch, Cory G.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S347 - S352