Sensitivity and Selectivity of Ion-Selective Electrodes Interpreted Using the Nernst-Planck-Poisson Model

被引:8
|
作者
Jasielec, Jerzy J. [1 ]
Mousavi, Zekra [2 ]
Granholm, Kim [2 ]
Sokolski, Tomasz [2 ]
Lewenstam, Andrzej [1 ,2 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, Phys Chem & Modeling Dept, Al Mickiewicza 30, PL-30059 Krakow, Poland
[2] Abo Akad Univ, Ctr Proc Analyt Chem & Sensor Technol ProSens, Johan Gadolin Proc Chem Ctr, Biskopsgatan 8, Turku 20500, Finland
关键词
LIQUID-MEMBRANE ELECTRODES; LOWER DETECTION LIMIT; TIME-DEPENDENT PHENOMENA; SEPARATE SOLUTION METHOD; TECHNICAL REPORT; NUMERICAL-SIMULATION; POTENTIAL RESPONSE; BULK OPTODES; COEFFICIENTS; SENSORS;
D O I
10.1021/acs.analchem.8b02659
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Nernst-Planck-Poisson model is used for modeling the sensitivity and selectivity of ion-selective electrodes (ISEs) with plastic membranes. Two pivotal parameters characterizing ISE response are in focus: sensitivity and selectivity. An interpretation of sensitivity, which considers the concurrent influence of anions and cations on the ISE slope, is presented. The interpretation of selectivity shows the validity and limits of approaches hitherto taken to measure the true (unbiased) selectivity coefficient. The validity of more idealized interpretations by the diffusion-layer model is conceived.
引用
收藏
页码:9644 / 9649
页数:6
相关论文
共 50 条
  • [21] STATISTICAL APPROACH FOR SELECTIVITY OF ION-SELECTIVE MEMBRANE ELECTRODES
    LITEANU, C
    HOPIRTEAN, E
    POPESCU, IC
    RICA, I
    STEFANIGA, E
    ANALYTICAL CHEMISTRY, 1978, 50 (08) : 1202 - 1209
  • [22] MODEL FOR TREATMENT OF SELECTIVITY COEFFICIENTS FOR SOLID-STATE ION-SELECTIVE ELECTRODES
    HULANICKI, A
    LEWENSTAM, A
    ANALYTICAL CHEMISTRY, 1981, 53 (09) : 1401 - 1405
  • [23] Perchlorate Selectivity of Anion Exchange Resins as Evaluated Using Ion-Selective Electrodes
    Kenji Yamamoto
    Shin’ya Mitsuda
    Naomi Ohtake
    Natsuki Murashige
    Satoshi Ohmuro
    Akio Yuchi
    Analytical Sciences, 2017, 33 : 159 - 163
  • [24] Electrochemical Impedance Spectroscopy (EIS) of ion sensors Direct modeling and inverse problem solving using the Nernst-Planck-Poisson (NPP) model and the HGS(FP) optimization strategy
    Grysakowski, B.
    Jasielec, J. J.
    Wierzba, B.
    Sokalski, T.
    Lewenstam, A.
    Danielewski, M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 662 (01) : 143 - 149
  • [25] Perchlorate Selectivity of Anion Exchange Resins as Evaluated Using Ion-Selective Electrodes
    Yamamoto, Kenji
    Mitsuda, Shin'ya
    Ohtake, Naomi
    Murashige, Natsuki
    Ohmuro, Satoshi
    Yuchi, Akio
    ANALYTICAL SCIENCES, 2017, 33 (02) : 159 - 163
  • [26] SENSITIVITY AND SELECTIVITY OF ION-SELECTIVE LIQUID MEMBRANE ELECTRODE
    ISHIBASHI, N
    JYO, A
    IMATO, T
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1978, 28-1 (04): : 708 - 708
  • [27] A multigrid method for the solution of ion transport using the Poisson Nernst Planck equations
    Mathur, Sanjay R.
    Murthy, Jayathi Y.
    IPACK 2007: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2007, VOL 2, 2007, : 571 - 580
  • [28] Ion-Selective Electrodes with Sensitivity in Strongly Diluted Solutions
    Mikhelson, K. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (02) : 112 - 116
  • [29] AUTOMATIC-DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES
    KISELEV, GG
    MEZHBURD, TA
    PETRUKHIN, OM
    AVDEEVA, EN
    TROFIMOVA, EV
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1985, 40 (01): : 76 - 81
  • [30] SELECTIVITY ENHANCEMENT OF CUPRIC AND LEAD ION-SELECTIVE ELECTRODES BY COMPLEXATION
    ISHIBASHI, N
    JYO, A
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1978, 28-1 (04): : 710 - 711