The MD Anderson experience with 3D dosimetry and an MR-linac

被引:6
作者
Ibbott, Geoffrey S. [1 ]
Le, Hannah J. [1 ]
Roe, Yvonne [1 ]
机构
[1] UT MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77054 USA
来源
10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) | 2019年 / 1305卷
关键词
RADIATION-THERAPY; MAGNETIC-FIELD; ACCELERATOR; IMPACT; IMRT;
D O I
10.1088/1742-6596/1305/1/012011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A recent extension of image guidance in radiation therapy has been brought about by the introduction of the MR-linac; a hybrid system comprising an MR imager and a medical linear accelerator. The University of Texas MD Anderson Cancer Center is one of seven institutes around the world that have collaborated with the manufacturer to develop this system and bring it into clinical use. In the process, a great deal has been learned about the influence of the magnetic field on radiation dose deposition and upon dosimetry systems. A number of dosimetry systems have been evaluated and issues affecting their performance have been investigated. The potential value of three-dimensional dosimetry systems has been explored.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A novel methodology for 3D deformable dosimetry
    Yeo, U. J.
    Taylor, M. L.
    Dunn, L.
    Kron, T.
    Smith, R. L.
    Franich, R. D.
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2203 - 2213
  • [32] Improved Ipsilateral Breast and Chest Wall Sparing With MR-Guided 3-fraction Accelerated Partial Breast Irradiation: A Dosimetric Study Comparing MR-Linac and CT-Linac Plans
    Musunuru, Hima Bindu
    Yadav, Poonam
    Olson, Stephanie J.
    Anderson, Bethany M.
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (03)
  • [33] Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer
    Vaezzadeh, S. A.
    Allahverdi, M.
    Nedaie, H. A.
    Aghili, M.
    Esfehani, M.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2012, 10 (3-4): : 145 - 150
  • [34] The IROC Houston Quality Assurance Program: Potential benefits of 3D dosimetry
    Followill, D. S.
    Molineu, H. A.
    Lafratta, R.
    Ibbott, G. S.
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [35] Using 3D dosimetry to quantify the Electron Return Effect (ERE) for MR-image-guided radiation therapy (MR-IGRT) applications
    Lee, Hannah J.
    Choi, Gye Won
    Alqathami, Mamdooh
    Kadbi, Mo
    Ibbott, Geoffrey
    [J]. 9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [36] Dosimetric characteristics of a reusable 3D radiochromic dosimetry material
    Park, Jong Min
    Park, So-Yeon
    Choi, Chang Heon
    Chun, Minsoo
    Han, Ji Hye
    Cho, Jin Dong
    Kim, Jung-in
    [J]. PLOS ONE, 2017, 12 (07):
  • [37] Development of a 3D remote dosimetry protocol compatible with MRgIMRT
    Mein, Stewart
    Rankine, Leith
    Adamovics, John
    Li, Harold
    Oldham, Mark
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 6018 - 6028
  • [38] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [39] On the feasibility of comprehensive high-resolution 3D remote dosimetry
    Juang, Titania
    Grant, Ryan
    Adamovics, John
    Ibbott, Geoffrey
    Oldham, Mark
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [40] 3D POLYMER GEL DOSIMETRY FOR QUALITY ASSURANCE IN RADIATION THERAPY
    Ceberg, Sofie
    Adliene, Diana
    Mattsson, Soren
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2017, : 30 - 35