Hybrid wavelet and EMD/ICA approach for artifact suppression in pervasive EEG

被引:36
作者
Bono, Valentina [1 ]
Das, Saptarshi [1 ]
Jamal, Wasifa [1 ]
Maharatna, Koushik [1 ]
机构
[1] Univ Southampton, Elect & Comp Sci, Southampton SO17 1BJ, Hants, England
关键词
Artifact suppression; EMD; ICA; WPT; Motion artifact; Wireless pervasive EEG; INDEPENDENT COMPONENT ANALYSIS; EMPIRICAL-MODE DECOMPOSITION; AUTOMATIC REMOVAL; SOURCE SEPARATION; ICA; OSCILLATIONS; CANCELLATION; RECORDINGS; ALGORITHMS; SIGNALS;
D O I
10.1016/j.jneumeth.2016.04.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Electroencephalogram (EEG) signals are often corrupted with unintended artifacts which need to be removed for extracting meaningful clinical information from them. Typically a priori knowledge of the nature of the artifacts is needed for such purpose. Artifact contamination of EEG is even more prominent for pervasive EEG systems where the subjects are free to move and thereby introducing a wide variety of motion-related artifacts. This makes hard to get a priori knowledge about their characteristics rendering conventional artifact removal techniques often ineffective. New method: In this paper, we explore the performance of two hybrid artifact removal algorithms: Wavelet Packet Transform followed by Independent Component Analysis (WPTICA) and Wavelet Packet Transform followed by Empirical Mode Decomposition (WPTEMD) in pervasive EEG recording scenario, assuming existence of no a priori knowledge about the artifacts and compare their performance with two existing artifact removal algorithms. Results: Artifact cleaning performance has been measured using Root Mean Square Error (RMSE) and Artifact to Signal Ratio (ASR)-an index similar to traditional Signal to Noise Ratio (SNR), and also by observing normalized power distribution topography over the scalp. Comparison with existing method(s): Comparison has been made first using semi-simulated signals and then with real experimentally acquired EEG data with commercially available 19-channel pervasive EEG system Enobio corrupted by eight types of artifact. Conclusions: Our explorations show that WPTEMD consistently gives best artifact cleaning performance not only in semi-simulated scenario but also in the case of real EEG data containing artifacts. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 107
页数:19
相关论文
共 49 条
[1]   Employing spatially constrained ICA and wavelet denoising, for automatic removal of artifacts from multichannel EEG data [J].
Akhtar, Muhammad Tahir ;
Mitsuhashi, Wataru ;
James, Christopher J. .
SIGNAL PROCESSING, 2012, 92 (02) :401-416
[2]  
[Anonymous], 2008, EEG signal processing
[3]  
[Anonymous], 2003, IEEE EURASIP WORKSH
[4]  
[Anonymous], 2010, IEEE REV BIOMED ENG, DOI DOI 10.1109/RBME.2010.2084078
[5]   EEG artifact removal-state-of-the-art and guidelines [J].
Antonio Urigueen, Jose ;
Garcia-Zapirain, Begona .
JOURNAL OF NEURAL ENGINEERING, 2015, 12 (03)
[6]  
Bono Valentina, 2014, 2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), P5864, DOI 10.1109/ICASSP.2014.6854728
[7]   Recovering EEG brain signals: Artifact suppression with wavelet enhanced independent component analysis [J].
Castellanos, Nazareth P. ;
Makarov, Valeri A. .
JOURNAL OF NEUROSCIENCE METHODS, 2006, 158 (02) :300-312
[8]   A Preliminary Study of Muscular Artifact Cancellation in Single-Channel EEG [J].
Chen, Xun ;
Liu, Aiping ;
Peng, Hu ;
Ward, Rabab K. .
SENSORS, 2014, 14 (10) :18370-18389
[9]   Muscle artifact removal from human sleep EEG by using independent component analysis [J].
Crespo-Garcia, Maite ;
Atienza, Mercedes ;
Cantero, Jose L. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (03) :467-475
[10]   Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram [J].
De Clercq, Wim ;
Vergult, Anneleen ;
Vanrumste, Bart ;
Van Paesschen, Wim ;
Van Huffel, Sabine .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (12) :2583-2587