Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: Retrospective analysis of 631 procedures

被引:164
作者
Yeow, KM
Tsay, PK
Cheung, YC
Lui, KW
Pan, KT
Chou, ASB
机构
[1] Chang Gung Univ, Chang Gung Mem Hosp, Dept Diagnost Radiol, Tao Yuan 333, Taiwan
[2] Chang Gung Univ, Chang Gung Mem Hosp, Dept Publ Hlth & Biostat, Tao Yuan 333, Taiwan
关键词
D O I
10.1097/01.RVI.0000071087.76348.C7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To analyze variables affecting diagnostic accuracy of computed tomography (CT)-guided percutaneous coaxial cutting needle biopsy of lung lesions. MATERIALS AND METHODS: A retrospective analysis of factors affecting diagnostic accuracy of CT-guided percutaneous coaxial cutting needle lung biopsy was performed in 631 consecutive procedures with confirmed final diagnoses. Benign and malignant needle biopsy results were cross-examined with correct and incorrect final outcomes to determine diagnostic accuracy. Factors affecting diagnostic accuracy were determined by multivariate logistic regression analysis of variables thought to affect diagnostic accuracy. A P value less than 0.05 was interpreted as statistically significant. RESULTS: The overall diagnostic accuracy of CT-guided percutaneous coaxial cutting needle biopsy of lung lesions was 95% (95% CI: 92.7%-96.2%). Sensitivity was 93%, specificity 98%, negative predictive value 6%, positive predictive value 99%, false-positive rate 0.7%, and false-negative rate 15%. The factors affecting diagnostic accuracy were final diagnoses (benign, 86%; malignant, 99%; chi(2) test, P < 0.001) and lesion size (lesions <1.5 cm, 84%; lesions 1.5-5.0 cm, 96%; lesions >5 cm, 93%; chi(2) test, P = 0.06). CONCLUSION: Benign lung lesions, lung lesions smaller than 1.5 cm (which pose technical difficulty), and lung lesions larger than 5 cm (which are associated with a higher necrosis rate) affect diagnostic accuracy of CT-guided percutaneous coaxial cutting needle biopsy of lung lesions.
引用
收藏
页码:581 / 588
页数:8
相关论文
共 18 条
[1]   CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration [J].
Arakawa, H ;
Nakajima, Y ;
Kurihara, Y ;
Niimi, H ;
Ishikawa, T .
CLINICAL RADIOLOGY, 1996, 51 (07) :503-506
[2]  
BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
[3]   Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment [J].
Boiselle, PM ;
Shepard, JAO ;
Mark, EJ ;
Szyfelbein, WM ;
Fan, CM ;
Slanetz, PJ ;
TrotmanDickenson, B ;
Halpern, EF ;
McLoud, TC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :661-666
[4]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[5]   Factors influencing pneumothorax rate at lung biopsy: Are dwell time and angle of pleural puncture contributing factors? [J].
Ko, JP ;
Shepard, JAO ;
Drucker, EA ;
Aquino, SL ;
Sharma, A ;
Sabloff, B ;
Halpern, E ;
McLoud, TC .
RADIOLOGY, 2001, 218 (02) :491-496
[6]   Percutaneous CT-guided biopsy of the lung: Comparison between aspiration and automated cutting needles using a coaxial technique [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Michel, P .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (04) :266-272
[7]   CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Montaudon, M ;
Vernejoux, JM ;
Dubrez, J .
CLINICAL RADIOLOGY, 2000, 55 (04) :281-287
[8]   Diagnostic accuracy and safety of CT-Guided percutaneous needle aspiration biopsy of the lung: Comparison of small and large pulmonary nodules [J].
Li, HQ ;
Boiselle, PM ;
Shepard, JAO ;
TrotmanDickenson, B ;
McLoud, TC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :105-109
[9]   Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle [J].
Lucidarme, O ;
Howarth, N ;
Finet, JF ;
Grenier, PA .
RADIOLOGY, 1998, 207 (03) :759-765
[10]   Should cutting needles replace needle aspiration of lung lesions? [J].
McLoud, TC .
RADIOLOGY, 1998, 207 (03) :569-570