Additional radiation sources in a treatment and control room of medical linear accelerators

被引:7
作者
Konefal, Adam [1 ]
Bieniasiewicz, Marcin [2 ]
Wendykier, Jacek [3 ]
Adamczyk, Sebastian [4 ]
Wronska, Aleksandra [5 ]
机构
[1] Univ Silesia Katowice, Inst Phys, Katowice, Poland
[2] Multidisciplinary Hosp Gorzow Wielkopolski, Dept Med Phys, Radiotherapy Ctr, Gorzow Wielkopolski, Poland
[3] Maria Sklodowska Curie Natl Res Inst Oncol, Gliwice Branch, Radiotherapy Planning Dept, Gliwice, Poland
[4] IntraOp Med, Sunnyvale, CA USA
[5] Jagiellonian Univ, Marian Smoluchowski Inst Phys, Krakow, Poland
关键词
Gamma-ray spectroscopy; Induced radioactivity; Neutrons; Radioactive decays; Prompt gamma rays; INDUCED RADIOACTIVITY; NEUTRON; RADIOTHERAPY; THERAPY; FIELD;
D O I
10.1016/j.radphyschem.2021.109513
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Typical medical linear accelerators generating high-energy photon beams used in radiotherapy are a source of neutrons and induced radioactivity undesirable mainly in radiological protection of medical staff but also for treatment of patients. The main source of the secondary radiation are massive components of an accelerator head. The purpose of this work was to study additional sources of gamma rays and neutrons in the treatment and control rooms for the Elekta accelerator. Identification of radioisotopes induced in several examined objects used and stored in the treatment room, and measurements of the spectrum of gamma rays originated in the treatment room door or travelling through it were carried out using a gamma-ray spectroscopy technique with an HPGe detector. Additionally, identification of neutron field was performed in the control room. In total, five nuclear reactions and five radioisotopes Mn-56, Sb-122, Fe-59, Li-7 and Al-28 were identified basing on gamma rays from the radioactive decays in the 20 cm x 20 cm electron applicator enabling collimation of the therapeutic electron beam, a Wood's alloy tray used as an additional shield against radiation, a special drawer for placing additional radiation shields, and a brick used to shield electronic modules of supporting equipment. Similarly, five nuclear reactions were also observed registering prompt gamma rays in the control room. The dominating nuclear reaction was the neutron capture. Moreover, the reactions induced by neutrons in the germanium crystal of the used HPGe detector confirmed the presence of neutrons in the control room.
引用
收藏
页数:7
相关论文
共 27 条
[1]  
[Anonymous], EVALUATED NUCL DATA
[2]  
[Anonymous], DATABASE PROMPT GAMM
[3]   MEASUREMENTS OF THERMAL AND RESONANCE NEUTRON FLUENCE AND INDUCED RADIOACTIVITY INSIDE BUNKERS OF MEDICAL LINEAR ACCELERATORS IN THE CENTER OF ONCOLOGY IN OPOLE, POLAND [J].
Bieniasiewicz, Marcin ;
Konefal, Adam ;
Wendykier, Jacek ;
Orlef, Andrzej .
ACTA PHYSICA POLONICA B, 2016, 47 (03) :771-776
[4]   Investigating in-field and out-of-field neutron contamination in high-energy medical linear accelerators based on the treatment factors of field size, depth, beam modifiers, and beam type [J].
Biltekin, Fatih ;
Yeginer, Mete ;
Ozyigit, Gokhan .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05) :517-523
[5]  
Dario B., 2012, Phys. Procedia, V26, P284, DOI DOI 10.1016/J.PHPRO.2012.03.036
[6]   Advances in radiotherapy techniques and delivery for non-small cell lung cancer: benefits of intensity-modulated radiation therapy, proton therapy, and stereotactic body radiation therapy [J].
Diwanji, Tejan P. ;
Mohindra, Pranshu ;
Vyfhuis, Melissa ;
Snider, James W., III ;
Kalavagunta, Chaitanya ;
Mossahebi, Sina ;
Yu, Jen ;
Feigenberg, Steven ;
Badiyan, Shahed N. .
TRANSLATIONAL LUNG CANCER RESEARCH, 2017, 6 (02) :131-147
[7]  
Firestone R.B., 1997, APS DIV NUCL PHYS M, P11
[8]   Neutron production during the interaction of monoenergetic electrons with a Tungsten foil in the radiotherapeutic energy range [J].
Gabriela Soto-Bernal, Tzinnia ;
Baltazar-Raigosa, Antonio ;
Medina-Castro, Diego ;
Rene Vega-Carrillo, Hector .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 868 :27-38
[9]   Current status of IMRT in head and neck cancer [J].
Gomez-Millan, Jaime ;
Romero Fernandez, Jesus ;
Medina Carmona, Jose Antonio .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (06) :371-375
[10]   Monte Carlo calculation of photo-neutron dose produced by circular cones at 18 MV photon beams [J].
Hosseinzadeh, Elham ;
Banaee, Nooshin ;
Nedaie, Hassan Ali .
REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (01) :39-46