Optimum Speckle Tracking Based on Ultrafast Ultrasound for Improving Blood Flow Velocimetry

被引:8
作者
He, Bingbing [1 ]
Zhang, Yufeng [1 ]
Zhang, Kexin [2 ]
Chen, Jianhua [1 ]
Zhang, Junhua [1 ]
Liang, Hong [1 ]
机构
[1] Yunnan Univ, Dept Elect Engn, Informat Sch, Kunming 650091, Yunnan, Peoples R China
[2] Kunming Med Univ, Affiliated Hosp 2, Dept Cardiovasc Med, Kunming 650031, Yunnan, Peoples R China
基金
中国国家自然科学基金;
关键词
Speckle; Ultrasonic imaging; Blood flow; Phantoms; Correlation; Estimation; Blood flow velocity profile (BFVP); coherent plane-wave compounding (CPWC); optimum comparison frame image; speckle tracking; ultrasound;
D O I
10.1109/TUFFC.2020.3012344
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Speckle tracking using optimum comparison frames (STO) is proposed to improve the blood flow velocity profile (BFVP) estimation based on ultrafast ultrasound with coherent plane-wave compounding. The optimum comparison frames are as far as possible from the reference frame image while possessing a speckle correlation above a given threshold. The correlation thresholds for different kernel sizes are determined via an experiment based on a vascular-mimicking phantom. In in vitro experiments with different peak velocities of the flow ranging from 0.38 to 1.18 m/s, the proposed STO method with three kernel sizes (0.46 x 0.46, 0.31 x 0.69, and 0.92 x 0.92 mm(2)) is used for the BFVP estimations. The normalized root mean square errors (NRMSEs) between the estimated and theoretical BFVPs are calculated and compared with the results based on the speckle tracking using adjacent-frame images. For the three kernel sizes, the mean relative decrements in the STO-based NRMSEs are 46.6%, 44.7%, and 52.9%, and the standard deviations are 36.8%, 37.6%, and 35.9%, respectively. The STO method is also validated by in vivo experiments using rabbit iliac arteries with contrast agents. With parabolic curves fitting to the mean velocity estimates, the average relative increments for the STO-based R-2 (coefficients of determination) are 7.22% and 6.25% for kernel sizes of 0.46 x 0.46 and 0.31 x 0.69 mm(2), respectively. In conclusion, the STO method improves the BFVP measurement accuracy, whereby accurate diagnosis information can be acquired for clinical applications.
引用
收藏
页码:494 / 509
页数:16
相关论文
共 45 条
[1]  
[Anonymous], 2008, INF MAN SEEK MARK CL
[2]  
[Anonymous], 2011, Ultrasound Imaging-Medical applications, DOI [DOI 10.5772/19729, 10.5772/19729]
[3]   Sub-Sample Displacement Estimation From Digitized Ultrasound RF Signals Using Multi-Dimensional Polynomial Fitting of the Cross-Correlation Function [J].
Azar, Reza Zahiri ;
Goksel, Orcun ;
Salcudean, Septimiu E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2403-2420
[4]  
Behler Russell H., 2009, 2009 IEEE International Ultrasonics Symposium, P2367, DOI 10.1109/ULTSYM.2009.5441497
[5]   Speckle tracking for multi-dimensional flow estimation [J].
Bohs, LN ;
Geiman, BJ ;
Anderson, ME ;
Gebhart, SC ;
Trahey, GE .
ULTRASONICS, 2000, 38 (1-8) :369-375
[6]  
Cao T., 2001, CHIN J UITRASONOGRAP, V10, P241
[7]   Role of hemodynamic shear stress in cardiovascular disease [J].
Cecchi, Emanuele ;
Giglioli, Cristina ;
Valente, Serafina ;
Lazzeri, Chiara ;
Gensini, Gian Franco ;
Abbate, Rosanna ;
Mannini, Lucia .
ATHEROSCLEROSIS, 2011, 214 (02) :249-256
[8]   PERFORMANCE OF ULTRASONIC SPECKLE TRACKING IN VARIOUS TISSUES [J].
CHEN, EJ ;
JENKINS, WK ;
OBRIEN, WD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (03) :1273-1278
[9]   The role of shear stress in the pathogenesis of atherosclerosis [J].
Cunningham, KS ;
Gotlieb, AI .
LABORATORY INVESTIGATION, 2005, 85 (01) :9-23
[10]   Coherent Plane Wave Compounding for Very High Frame Rate Ultrasonography of Rapidly Moving Targets [J].
Denarie, Bastien ;
Tangen, Thor Andreas ;
Ekroll, Ingvild Kinn ;
Rolim, Natale ;
Torp, Hans ;
Bjastad, Tore ;
Lovstakken, Lasse .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) :1265-1276