Relative Risk Factors for Cardiac Erosion Following Transcatheter Closure of Atrial Septal Defects A Case-Control Study

被引:106
作者
McElhinney, Doff B. [1 ]
Quartermain, Michael D. [2 ]
Kenny, Damien [3 ]
Alboliras, Ernerio [4 ]
Amin, Zahid [5 ]
机构
[1] Stanford Univ, Lucille Packard Childrens Hosp, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[2] Wake Forest Univ, Bowman Gray Sch Med, Dept Pediat, Winston Salem, NC 27103 USA
[3] Our Ladys Hosp Sick Children, Dublin, Ireland
[4] Banner Childrens Specialists, Div Pediat Cardiol, Mesa, AZ USA
[5] Georgia Regents Univ, Childrens Hosp Georgia, Dept Pediat, Augusta, GA 30912 USA
关键词
amplatzer septal occluder; cardiac tamponade; echocardiography; erosion; heart diseases; vascular closure devices; OCCLUDER DEVICES; PERCUTANEOUS CLOSURE; ADVERSE EVENTS; PERFORATION; ECHOCARDIOGRAPHY; RECOMMENDATIONS; COMPLICATIONS; MANUFACTURER; PLACEMENT; OUTCOMES;
D O I
10.1161/CIRCULATIONAHA.115.019987
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Transcatheter closure of secundum atrial septal defects (ASD) using the Amplatzer septal occluder is generally safe and effective, but erosion into the pericardial space or aorta has been described. Although the absolute risk of this complication is low, there has been no assessment of relative risk factors. Methods and Results-All erosions reported to St. Jude Medical after ASD closure with an Amplatzer septal occluder (cases) were compared with controls (matched 2: 1) who underwent ASD closure but did not develop an erosion. A total of 125 erosions were reported between 2002 and 2014, including 95 with an available echocardiogram. The median duration from implant to erosion was 14 days, but was >1 year in 16 patients. Nine patients (all age >= 17 years) who died were more likely to have an oversized device, and to have erosion into the aorta, than survivors. Aortic or superior vena cava rim deficiencies were more common in cases than in controls. In addition, larger balloon-sized ASD diameter, Amplatzer septal occluder device size, and device size-ASD diameter difference, and smaller weight: device size ratio were associated with erosion. On multivariable analysis, deficiency of any rim, device >5 mm larger than ASD diameter, and weight: device size ratio were associated with erosion. Conclusions-In addition to aortic rim deficiency, which was almost universal among erosion cases, there were several relative risk factors for erosion after ASD closure with the Amplatzer septal occluder device. To understand the mechanisms of and absolute risk factors for this uncommon but serious complication, an adequately powered prospective study with thorough echocardiographic evaluation will be critical.
引用
收藏
页码:1738 / +
页数:12
相关论文
共 29 条
  • [1] Aggoun Y, 2002, ARCH MAL COEUR VAISS, V95, P479
  • [2] Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
    Amin, Z
    Hijazi, ZM
    Bass, JL
    Cheatham, JP
    Hellenbrand, WE
    Kleinman, CS
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) : 496 - 502
  • [3] Echocardiographic Predictors of Cardiac Erosion After Amplatzer Septal Occluder Placement
    Amin, Zahid
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (01) : 84 - 92
  • [4] Valvular and congenital heart disease -: Treatment of isolated secundum atrial septal defects:: Impact of age and defect morphology in 1,013 consecutive patients
    Butera, Gianfranco
    Romagnoli, Enrico
    Carminati, Mario
    Chessa, Massimo
    Piazza, Luciane
    Negura, Diana
    Giamberti, Alessandro
    Abella, Raul
    Pome, Giuseppe
    Condoluci, Claudia
    Frigiola, Alessandro
    [J]. AMERICAN HEART JOURNAL, 2008, 156 (04) : 706 - 712
  • [5] Cabrera Marcelo, 2011, J Invasive Cardiol, V23, pE139
  • [6] Early and late complications associated with transcatheter occlusion of secundum atrial septal defect
    Chessa, M
    Carminati, M
    Butera, G
    Bini, RM
    Drago, M
    Rosti, L
    Giamberti, A
    Pomè, G
    Bossone, E
    Frigiola, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) : 1061 - 1065
  • [7] Circulatory System Devices Panel of the Medical Devices Advisory Committee, 2012, ST JUD MED AMPLATZER
  • [8] Percutaneous atrial Septal Occluder devices and cardiac erosion: A review of the literature
    Crawford, Geoffrey B.
    Brindis, Ralph G.
    Krucoff, Mitchell W.
    Mansalis, Benjamin P.
    Carroll, John D.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (02) : 157 - 167
  • [9] Delaney Jeffrey W, 2007, Congenit Heart Dis, V2, P256, DOI 10.1111/j.1747-0803.2007.00107.x
  • [10] Erosions, erosions, and erosions! Device closure of atrial septal defects: How safe is safe?
    Diab, Karim
    Kenny, Damien
    Hijazi, Ziyad M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (02) : 168 - 174