Optical coherence tomography (OCT) has found great success in ophthalmology where it plays a key role in screening and diagnostics. Clinical ophthalmic OCT systems are typically deployed as tabletop instruments that require chinrest stabilization and trained ophthalmic photographers to operate. These requirements preclude OCT diagnostics in bed-bound or unconscious patients who cannot use a chinrest, and restrict OCT screening to ophthalmology offices. We present a robotically-aligned OCT scanner capable of automatic eye imaging without chinrests. The scanner features eye tracking from fixed-base RGB-D cameras for coarse and stereo pupil cameras for fine alignment, as well as galvanometer aiming for fast lateral tracking, reference arm adjustment for fast axial tracking, and a commercial robot arm for slow lateral and axial tracking. We demonstrate the system's performance autonomously aligning with stationary eyes, pursuing moving eyes, and tracking eyes undergoing physiologic motion. The system demonstrates sub-millimeter eye tracking accuracy, 12 mu m lateral pupil tracking accuracy, 83.2 ms stabilization time following step disturbance, and 9.7 Hz tracking bandwidth.
引用
收藏
页码:8897 / 8903
页数:7
相关论文
共 15 条
[1]  
AAO Cornea/External Disease PPP Panel Hoskins Center for Qual- ity Eye Care, 2013, AM ACAD OPHTHALMOLOG
[2]  
AAO PPP Retina/Vitreous Panel Hoskins Center for Quality Eye Care, 2017, AM ACAD OPHTHALMOLOG
[3]   Correction of eye-motion artifacts in AO-OCT data sets [J].
Capps, Arlie G. ;
Zawadzki, Robert J. ;
Yang, Qiang ;
Arathorn, David W. ;
Vogel, Curtis R. ;
Hamann, Bernd ;
Werner, John S. .
OPHTHALMIC TECHNOLOGIES XXI, 2011, 7885
[4]   Pupil tracking optical coherence tomography for precise control of pupil entry position [J].
Carrasco-Zevallos, Oscar ;
Nankivil, Derek ;
Keller, Brenton ;
Viehland, Christian ;
Lujan, Brandon J. ;
Izatt, Joseph A. .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (09) :3405-3419
[5]   Automatic generation and detection of highly reliable fiducial markers under occlusion [J].
Garrido-Jurado, S. ;
Munoz-Salinas, R. ;
Madrid-Cuevas, F. J. ;
Marin-Jimenez, M. J. .
PATTERN RECOGNITION, 2014, 47 (06) :2280-2292
[6]   Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics [J].
Jung, Woonggyu ;
Kim, Jeehyun ;
Jeon, Mansik ;
Chaney, Eric J. ;
Stewart, Charles N. ;
Boppart, Stephen A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) :741-744
[7]   Motion correction in optical coherence tomography volumes on a per A-scan basis using orthogonal scan patterns [J].
Kraus, Martin F. ;
Potsaid, Benjamin ;
Mayer, Markus A. ;
Bock, Ruediger ;
Baumann, Bernhard ;
Liu, Jonathan J. ;
Hornegger, Joachim ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06) :1182-1199
[8]   In vivo cellular-resolution retinal imaging in infants and children using an ultracompact handheld probe [J].
LaRocca, Francesco ;
Nankivil, Derek ;
DuBose, Theodore ;
Toth, Cynthia A. ;
Farsiu, Sina ;
Izatt, Joseph A. .
NATURE PHOTONICS, 2016, 10 (09) :580-584
[9]   Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror [J].
Lu, Chen D. ;
Kraus, Martin F. ;
Potsaid, Benjamin ;
Liu, Jonathan J. ;
Choi, WooJhon ;
Jayaraman, Vijaysekhar ;
Cable, Alex E. ;
Hornegger, Joachim ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01) :293-311
[10]   Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe [J].
Nankivil, Derek ;
Waterman, Gar ;
LaRocca, Francesco ;
Keller, Brenton ;
Kuo, Anthony N. ;
Izatt, Joseph A. .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (11) :4516-4528