High-resolution organ dosimetry for human exposure to low-frequency magnetic fields

被引:112
作者
Dawson, TW [1 ]
Stuchly, MA [1 ]
机构
[1] Univ Victoria, Dept Elect & Comp Engn, Victoria, BC V8W 3P6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
biological organs; conductivity; electromagnetic field effects; finite difference methods; frequency domain analysis; magnetic field effects; power transmission biological effects;
D O I
10.1109/20.668071
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electric fields and current densities induced in an anatomically realistic, high-resolution model of the human body are computed, The results are given for various organs in terms of average and maximum values for 60-Hz uniform magnetic fields in three orthogonal orientations. The effects of variations in the tissue conductivity are evaluated. The data presented can be linearly scaled to frequencies pip to 100 kHz without an appreciable error, provided that the changes in tissue conductivity with frequency are taken into account. The scalar potential finite difference (SPFD) method with an appropriate matrix preconditioner and a conjugate gradient solver were used to model the problem. This approach resulted in a high computational efficiency that facilitated high-resolution (3.6 mm voxels) modeling involving 1736872 unknowns, All computations were performed on a Hewlett-Packard 9000/735 Unix workstation using under 200 MB of physical memory. Typical computation times were of be order of 25 h. The results show that conductivity variations, source orientation, and model realism can significantly affect the dosimetry values, particularly in comparison with more simplistic models. They also show that the maximum current density in several tissues can exceed 10 mA m(-2) in a 60-Hz, 0.5-mT uniform magnetic field.
引用
收藏
页码:708 / 718
页数:11
相关论文
共 28 条
[1]  
[Anonymous], 1990, HEALTH PHYS, V58, P113
[2]  
Barrett R., 1994, Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods, V2nd ed.
[3]  
DACUNHA RD, 1993, PIM 2 0 PARALLEL ITE
[4]  
Dawson T. W., 1996, Applied Computational Electromagnetics Society Journal, V11, P72
[5]  
Dawson T. W., 1996, Applied Computational Electromagnetics Society Journal, V11, P63
[6]   An analytic solution for verification of computer models for low-frequency magnetic induction [J].
Dawson, TW ;
Stuchly, MA .
RADIO SCIENCE, 1997, 32 (02) :343-367
[7]   Application of the finite difference time domain algorithm to quasi-static field analysis [J].
DeMoerloose, J ;
Dawson, TW ;
Stuchly, MA .
RADIO SCIENCE, 1997, 32 (02) :329-341
[8]  
FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
[9]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[10]   CURRENTS INDUCED IN A MODEL OF A RAT EXPOSED TO EMP IN A PARALLEL-PLATE LINE - CALCULATIONS AND EXPERIMENTAL RESULTS [J].
GAO, BQ ;
GANDHI, OP ;
MATHUR, S ;
BATES, F ;
BASSEN, H .
BIOELECTROMAGNETICS, 1992, 13 (05) :439-443