Application of the permanent magnet synchronous motors for tower cranes

被引:4
作者
Knypinski, Lukasz [1 ,3 ]
Krupinski, Jacek [2 ]
机构
[1] Poznan Univ Tech, Poznan, Poland
[2] Krupinski Cranes Sp Zoo, Ul Obywatelska 2A, PL-80259 Gdansk, Poland
[3] Poznan Univ Tech, Inst Elect Engn & Elect, Poznan, Poland
来源
PRZEGLAD ELEKTROTECHNICZNY | 2020年 / 96卷 / 01期
关键词
tower cranes; permanent magnet synchronous motors; hoist winch drive; efficiency; TORQUE RIPPLE; DESIGN;
D O I
10.15199/48.2020.01.07
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents the results of experimental research concerning the application of the permanent magnet synchronous motors for tower cranes. The modern permanent magnet synchronous motors (PMSM) are characterized by better operating parameters in relation to squirrel cage induction machines. In the first stage of our research, the designed crane has been equipped with commercially produced permanent magnet synchronous motors. The test bench for examination of PMSM properties was built. The preliminary selected permanent magnet (PM) motors were experimentally tested to verify its performances in crane applications. Selected results of experimental research for hoist winch drive are presented and discussed.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 17 条
[1]  
Agamloh E. B., IEEE WORKSH EL MACH, DOI [10.1109/WEMDCD.2013.6525163, DOI 10.1109/WEMDCD.2013.6525163]
[2]   Cogging torque and torque ripple analysis of permanent magnet flux-switching machine having two stators [J].
Awah, Chukwuemeka Chijioke ;
Okoro, Ogbonnaya Inya ;
Chikuni, Edward .
ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (01) :115-133
[3]  
Backstrand J. E., 1992, APPL ADJUSTABLE FREQ, DOI [10.1109/IAS.1992.244208, DOI 10.1109/IAS.1992.244208]
[4]   Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor [J].
Baranski, Mariusz ;
Demenko, Andrzej ;
Lyskawinski, Wieslaw ;
Szelag, Wojciech .
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2011, 30 (03) :832-840
[5]  
BELMANS R, 1993, IAS 93, PTS 1-3, P473, DOI 10.1109/IAS.1993.298966
[6]   The use of computer simulations and measurements in determining the energy efficiency of photovoltaic installations [J].
Bugala, Artur ;
Bednarek, Karol .
COMPUTER APPLICATIONS IN ELECTRICAL ENGINEERING (ZKWE'2018), 2018, 19
[7]   Influence of harmonic voltage coupling on torque ripple of permanent magnet synchronous motor [J].
Geng, Shengtao ;
Zhang, Yong ;
Qiu, Hongbo ;
Yang, Cunxiang ;
Yi, Ran .
ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (02) :399-410
[8]  
Gwozdziewicz M., 2017, PRZ ELEKTROTECHNICZN, V93, P1
[9]  
Haifeng Z., 2017, INT C EL MACH SYST I, DOI [10.1109/ICEMS.2017.8055957, DOI 10.1109/ICEMS.2017.8055957]
[10]   Optimal design of the rotor geometry of line-start permanent magnet synchronous motor using the bat algorithm [J].
Knypinski, Lukasz .
OPEN PHYSICS, 2017, 15 (01) :965-970