Dynamic magnetic resonance imaging of the cerebrospinal fluid flow within the cerebral aqueduct by different FISP 2D sequences

被引:2
|
作者
Lucic, Milos A. [1 ]
Koprivsek, Katarina M. [1 ]
Till, Viktor [2 ]
Vesic, Zoran [3 ]
机构
[1] Ctr Imidzing Dijagnostiku, Inst Onkol Vojvodine, Inst Put 4, Sremska Kamenica 21204, Serbia
[2] Ctr Radiol, Klin Ctr Vojvodine, Novi Sad, Serbia
[3] Ministarstvo Odbrane Republ Srbije, Belgrade, Serbia
关键词
magnetic resonance imaging; electrocardiography; cerebrospinal fluid; cerebral ventricles; anatomy; cross-sectional; STATE FREE PRECESSION; STEADY-STATE; BRAIN MOTION; CSF FLOW; HYDROCEPHALUS;
D O I
10.2298/VSP1005357L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. A vast majority of current radiogical techniques, such as computerized tomography (CT) and magnetic resonance imaging (MRI) have great potencial of vizualization and delineation of cerebrospinal fuid spaces morphology within cerebral aqueduct. The aim of this study was to determine the possibilities of two differently acquired FISP (Fast Imaging with Steady State Precession) 2D MR sequences in the estimation of the pulsatile cerebrospinal fluid (CSF) flow intensity through the normal cerebral aqueduct. Methods. Sixty eight volunteers underwent brain MRI on 1.5T MR imager with additionally performed ECG retrospectively gated FISP 2D sequences (first one, as the part of the standard software package, with following technical parameters: TR 40, TE 12, FA 17, Matrix: 192 x 256, Acq 1, and the second one, experimentally developed by our investigation team: TR 30, TE 12, FA 70, Matrix: 192 x 256, Acq 1) respectively at two fixed slice positions midsagittal and perpendicular to cerebral aqueduct, displayed and evaluated by mulriplegated images in a closed-loop cinematographic (CINE) format. Results. Normal brain morphology with preserved patency of the cerebral aqueduct in all of 68 healthy volunteers was demonstrated on MRI examination. Cerebrospinal fluid flow within the cerebral aqueduct was distinguishable on both CINE MRI studies in midsagittal plane, but the estimation of intraaqueductal CSF flow in perpendicular plane was possible on CINE MRI studies acquired with experimentally improved FISP 2D (TR 30, FA 70) sequence only. Conclusion. Due to the changes of technical parameters CINE MRI study acquired with FISP 2D (FR 30, FA 70) in perpendicular plane demonstrated significantly higher capability in the estimation of the CSF pulsation intensity within the cerebral aqueduct.
引用
收藏
页码:357 / 363
页数:7
相关论文
共 50 条
  • [41] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Gabbour, Maya
    Schnell, Susanne
    Jarvis, Kelly
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    PEDIATRIC RADIOLOGY, 2015, 45 (06) : 804 - 813
  • [42] Magnetic resonance 4D flow analysis of cerebrospinal fluid dynamics in Chiari I malformation with and without syringomyelia
    Alexander C. Bunck
    Jan Robert Kroeger
    Alena Juettner
    Angela Brentrup
    Barbara Fiedler
    Gerard R. Crelier
    Bryn A. Martin
    Walter Heindel
    David Maintz
    Wolfram Schwindt
    Thomas Niederstadt
    European Radiology, 2012, 22 : 1860 - 1870
  • [43] Magnetic resonance 4D flow analysis of cerebrospinal fluid dynamics in Chiari I malformation with and without syringomyelia
    Bunck, Alexander C.
    Kroeger, Jan Robert
    Juettner, Alena
    Brentrup, Angela
    Fiedler, Barbara
    Crelier, Gerard R.
    Martin, Bryn A.
    Heindel, Walter
    Maintz, David
    Schwindt, Wolfram
    Niederstadt, Thomas
    EUROPEAN RADIOLOGY, 2012, 22 (09) : 1860 - 1870
  • [44] Hyperintensity of Cerebrospinal Fluid on T2-Weighted Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Caused by High Inspired Oxygen Fraction
    Moioli, Melania
    Levionnois, Olivier
    Stein, Veronika M.
    Schupbach, Gertraud
    Schmidhalter, Marta
    Schweizer-Gorgas, Daniela
    FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [45] Visualization of wrist ligaments with 3D and 2D magnetic resonance imaging at 3 Tesla
    Gotestrand, Simon
    Bjorkman, Anders
    Bjorkman-Burtscher, Isabella M.
    Ab-Fawaz, Rana
    Kristiansson, Ingvar
    Lundin, Bjorn
    Geijer, Mats
    ACTA RADIOLOGICA, 2022, 63 (03) : 368 - 375
  • [46] Elevated Cerebral Blood Flow and Volume in Systemic Lupus Measured by Dynamic Susceptibility Contrast Magnetic Resonance Imaging
    Gasparovic, Charles M.
    Roldan, Carlos A.
    Sibbitt, Wilmer L., Jr.
    Qualls, Clifford R.
    Mullins, Paul G.
    Sharrar, Janeen M.
    Yamamoto, J. Jeremy
    Bockholt, H. Jeremy
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (09) : 1834 - 1843
  • [47] CHARACTERISTICS OF CEREBROSPINAL FLUID FLOW IN CAVALIER KING CHARLES SPANIELS ANALYZED USING PHASE VELOCITY CINE MAGNETIC RESONANCE IMAGING
    Cerda-Gonzalez, Sofia
    Olby, Natasha J.
    Broadstone, Richard
    McCullough, Susan
    Osborne, Jason A.
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (05) : 467 - 476
  • [48] Quantitative measurements on the human ascending aortic flow using 2D cine phase-contrast magnetic resonance imaging
    Yokosawa, S
    Nakamura, M
    Wada, S
    Isoda, H
    Takeda, H
    Yamaguchi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2005, 48 (04) : 459 - 467
  • [49] Analysis of cerebrospinal fluid flow dynamics and morphology in Chiari I malformation with cine phase-contrast magnetic resonance imaging
    Wang, Cheng-Shi
    Wang, Xing
    Fu, Chu-Hua
    Wei, Lu-Qing
    Zhou, Dai-Quan
    Lin, Jiang-Kai
    ACTA NEUROCHIRURGICA, 2014, 156 (04) : 707 - 713
  • [50] Impact of compressed sensing (CS) acceleration of two-dimensional (2D) flow sequences in clinical paediatric cardiovascular magnetic resonance (CMR)
    Moscatelli, Sara
    Gatehouse, Peter
    Krupickova, Sylvia
    Mohiaddin, Raad
    Voges, Inga
    Giese, Daniel
    Nielles-Vallespin, Sonia
    Pennell, Dudley J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (06) : 869 - 876