Scatter correction for flat detector cone-beam CT based on simulated sphere models

被引:16
|
作者
Bertram, M. [1 ]
Hohmann, S. [1 ]
Wiegert, J. [1 ]
机构
[1] Philips Res Europe, Aachen, Germany
关键词
D O I
10.1118/1.2760399
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Uncompensated scattered radiation is one of the major image quality deteriorating factors in flat detector cone‐beam CT. Purpose of this work is to develop a fast, practical, and accurate method for a posteriori correction of X‐ray scatter. Method and Materials: Scatter estimation and correction is carried out using a novel approach based on locally approximating the imaged object by water sphere models. In each projection, the scatter contribution of each ray from the source to the individual detector pixels is derived from a pre‐calculated database of pencil‐beam Monte‐Carlo simulations. The different sphere configurations have the advantage over related existing methods that they allow to accurately reproduce scatter contributions of individual rays regardless of the position of object penetration. Systematic evaluation was carried out by constructing an extensive database of Monte‐Carlo patient simulations, by performing scatter measurements of 15 phantoms on a bench‐top X‐ray system, and based on rotational C‐arm acquisitions from clinical interventional procedures. Results: The novel method was found to produce far superior results than related state‐of‐the‐art approaches. Based on simulated projections of 13 CT data sets of different body regions (head, thorax, abdomen, liver, pelvis), an average reduction of scatter‐caused inhomogeneities from 117 HU to 11 HU per‐voxel deviation from the ground truth was achieved. For individual data sets, the average level of the estimated scatter deviated from the respective optimum by only 5% as compared to a minimum of 14% for tested state‐of‐the‐art approaches. Experimental evaluation and application to clinical data confirmed robustness and efficient reduction of cupping and streak artifacts in reconstructed images. Conclusion: A practical software‐based method was developed allowing to accurately estimate scatter contributions in X‐ray projections. Utilization of this method efficiently reduces scatter‐caused artifacts, and thus substantially improves image quality in flat detector cone‐beam CT. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2342 / 2343
页数:2
相关论文
共 50 条
  • [1] Flat Detector Cone-Beam CT
    Kachelriess, Marc
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (02): : 91 - 91
  • [2] Scatter Correlation and Correction for Cone-Beam CT Using Dual-Layer Flat Panel Detector
    Gu, S.
    Qi, B.
    Gao, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1339 - 1365
  • [4] Correction of scatter in megavoltage cone-beam CT
    Spies, L
    Ebert, M
    Groh, BA
    Hesse, BM
    Bortfeld, T
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : 821 - 833
  • [5] A new correction method for flat panel detector in Cone-Beam CT
    Zhang, Hua
    Huang, Kuidong
    Shi, Yikai
    CEIS 2011, 2011, 15
  • [6] Measurement-Based Cross-Scatter Correction in Dual Detector Cone-Beam CT
    Giles, W.
    Bowsher, J.
    Li, H.
    Yin, F.
    MEDICAL PHYSICS, 2011, 38 (06) : 3446 - +
  • [7] Scatter Correction for Cone-Beam CT in Radiation Therapy
    Zhu, L.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Correction of veiling glare and scatter in cone-beam CT
    Baba, R
    Ueda, K
    Takagi, H
    RADIOLOGY, 1999, 213P : 453 - 453
  • [9] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27
  • [10] Noise suppression in scatter correction for cone-beam CT
    Zhu, Lei
    Wang, Jing
    Xing, Lei
    MEDICAL PHYSICS, 2009, 36 (03) : 741 - 752