High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation

被引:25
作者
Meixner, Christian R. [1 ]
Liebig, Patrick [2 ,3 ]
Speier, Peter [2 ]
Forman, Christoph [2 ]
Hensel, Bernhard [3 ]
Schmidt, Manuel [4 ]
Saake, Marc [1 ]
Uder, Michael [1 ]
Doerfler, Arnd [4 ]
Heidemann, Robin M. [2 ]
Schmitter, Sebastian [5 ,6 ]
Nagel, Armin M. [1 ,6 ,7 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Siemens Healthcare GmbH, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, Max Schalaach Stiftungsprof Biomed Tech MSBT, Erlangen, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Dept Neuroradiol, Erlangen, Germany
[5] Phys Tech Bundesanstalt, Berlin, Germany
[6] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
[7] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Phys, Erlangen, Germany
关键词
Time-of-flight; MR-angiography; Compressed sensing; 7; Tesla; VERSE; Ultra-high field; MAGNETIC-RESONANCE ANGIOGRAPHY; CONTRAST; TOF; ENHANCEMENT; ALGORITHM; ARTERIES; IMPACT; PULSES; POWER;
D O I
10.1016/j.mri.2019.08.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: 3D Time-of-Flight (TOF) MR-angiography (MRA) substantially benefits from ultra-high magnetic field strengths (>= 7 T) due to increased Signal-to-Noise ratio and improved contrast. However, high-resolution TOF-MRA usually requires long acquisition times. In addition, specific absorption rate constraints limit the choice of optimal pulse sequence parameters, especially if venous saturation is employed. Purpose: To implement and evaluate an arterial TOF-MRA for accelerated high-resolution angiography at ultra-high magnetic field strength. Field strengths/sequence: 7 T modified gradient-echo TOF sequence including venous saturation using Variable-Rate Selective Excitation (VERSE), Compressed Sensing (CS) and sparse application of saturation pulses, called segmentation, were included for acceleration. Assessment: To analyze the acceleration techniques all volunteers were examined with the same protocols. CS with different sampling patterns and regularization factors as well as segmentation were applied for acceleration. For comparison, conventional acceleration techniques were applied (GRAPPA PAT 3 and Partial Fourier (6/8 in slice/phase encoding)). Images were co-registered and 40 mm thick transversal maximum intensity projections were created to calculate the relative number of vessels. To analyze the visibility of small vessels, the lenticulostriate arteries (LSA) were examined. This was done via multiscale vessel enhancement filtering in a VOI and quantification via Fiji ImageJ as well as qualitatively evaluation by two radiologists. Additionally, the venous/arterial vessel-to-background ratios (vVBR/aVBR) were calculated for chosen protocols. Results: For the acceleration of a high resolution TOF-MRA (0.31 mm isotropic), under-sampling of 9.6 showed aliasing artifacts, whereas 7.2 showed no aliasing. The regularization factor R had a strong impact on the image quality according to smoothing (R = 0.01 to R = 0.005) and noise (R = 0.0005 to R = 0.00005). With the alternating sampling patterns it was shown that the k-space center should not be under-sampled too much. Additionally segmentation could be verified to be feasible for stronger acceleration with sufficient venous suppression. Conclusion: The combination of several independent techniques (VERSE, CS with acceleration factor 7.2, R = 0.001, Poisson disc radius of 80%, 3 segments) enables the application of high-resolution (0.31 mm isotropic) TOF-MRA with venous saturation at 7 T in clinical time settings (TA approximate to 5 min) and within the SAR limits.
引用
收藏
页码:193 / 204
页数:12
相关论文
共 52 条
[1]   IMPROVED MR-ANGIOGRAPHY - MAGNETIZATION-TRANSFER SUPPRESSION WITH VARIABLE FLIP ANGLE EXCITATION AND INCREASED RESOLUTION [J].
ATKINSON, D ;
BRANTZAWADZKI, M ;
GILLAN, G ;
PURDY, D ;
LAUB, G .
RADIOLOGY, 1994, 190 (03) :890-894
[2]   A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems [J].
Beck, Amir ;
Teboulle, Marc .
SIAM JOURNAL ON IMAGING SCIENCES, 2009, 2 (01) :183-202
[3]   3D multi-scale vessel enhancement filtering based on curvature measurements: application to time-of-flight MRA [J].
Chapman, BE ;
Parker, DL .
MEDICAL IMAGE ANALYSIS, 2005, 9 (03) :191-208
[4]   VARIABLE-RATE SELECTIVE EXCITATION [J].
CONOLLY, S ;
NISHIMURA, D ;
MACOVSKI, A ;
GLOVER, G .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :440-458
[5]   MR Angiography and Imaging for the Evaluation of Middle Cerebral Artery Atherosclerotic Disease [J].
Degnan, A. J. ;
Gallagher, G. ;
Teng, Z. ;
Lu, J. ;
Liu, Q. ;
Gillard, J. H. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) :1427-1435
[6]  
Deutschmann HA, 2007, AM J NEURORADIOL, V28, P628
[7]   AN ALGORITHM FOR RESTRICTED LEAST-SQUARES REGRESSION [J].
DYKSTRA, RL .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1983, 78 (384) :837-842
[8]  
Frangi AF., MULTISCALE VESSEL EN
[9]   Comparison of intracranial 3D-ToF-MRA with and without parallel acquisition techniques at 1.5T and 3.0T: Preliminary results [J].
Gaa, J ;
Weidauer, S ;
Requardt, M ;
Kiefer, B ;
Lanfermann, H ;
Zanella, FE .
ACTA RADIOLOGICA, 2004, 45 (03) :327-332
[10]   Comparison of volume, four- and eight-channel head coils using standard and parallel imaging [J].
Gizewski, ER ;
Maderwald, S ;
Wanke, I ;
Goehde, S ;
Forsting, M ;
Ladd, ME .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1555-1562