Usefulness of Pipelle endometrial biopsy in the diagnosis of women at risk for ectopic pregnancy

被引:19
作者
Barnhart, KT
Gracia, CR
Reindl, B
Wheeler, JE
机构
[1] Univ Penn, Med Ctr, Ctr Reprod Med & Surg, Div Reprod Endocrinol & Infertil, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Ctr Clin Epidemiol & Biostat, Philadelphia, PA 19104 USA
[3] Univ Penn, Med Ctr, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[4] Providence Hlth Syst, Portland, OR USA
关键词
chorionic villi; ectopic pregnancy; endometrial biopsy; Pipelle; curettage;
D O I
10.1067/mob.2003.228
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: The purpose of this study was to determine the accuracy of endometrial Pipelle (Unimar) biopsy to detect chorionic villi in suspected ectopic pregnancy. STUDY DESIGN: This was a blinded prospective trial that involved 32 women who were in stable condition with suspected ectopic pregnancy. Endometrial pipelle sampling was performed before uterine dilation and curettage. Pipelle and frozen section results were compared with final disease. RESULTS: Ten of 32 patients (31%) had chorionic villi that was consistent with a miscarriage; 22 of 32 patients (69%) had none detected. Pipelle biopsy had a sensitivity of 30% (95% Cl, 6.7-65.2), a specificity of 100% (95% Cl, 84.5-100), a positive predictive value of 100% (95% Cl, 29.2-100), and a negative predictive value of 76% (95% Cl, 56.5-87). Frozen section had a sensitivity of 87.5%.(95% Cl, 47.3-99.7), a specificity of 100% (95% Cl, 83.1-100), a positive predictive value of 100% (95% Cl, 59-100), and a negative predictive value of 95.3% (95% Cl, 76.1-99.8). CONCLUSION: In patients with suspected ectopic pregnancy, Pipelle sampling is not a substitute for curettage because the sensitivity and predictive values are unacceptable.
引用
收藏
页码:906 / 909
页数:4
相关论文
共 23 条
  • [1] BARNHART K, 1994, OBSTET GYNECOL, V84, P1010
  • [2] Presumed diagnosis of ectopic pregnancy
    Barnhart, KT
    Katz, I
    Hummel, A
    Gracia, CR
    [J]. OBSTETRICS AND GYNECOLOGY, 2002, 100 (03) : 505 - 510
  • [3] Diagnostic accuracy of ultrasound above and below the beta-hCG discriminatory zone
    Barnhart, KT
    Simhan, H
    Kamelle, SA
    [J]. OBSTETRICS AND GYNECOLOGY, 1999, 94 (04) : 583 - 587
  • [4] CARSON SA, 1993, NEW ENGL J MED, V329, P1174
  • [5] *CDCP, 1992, MMWR-MORBID MORTAL W, V41, P591
  • [6] Centers for Disease Control and Prevention (CDC), 1995, MMWR-MORBID MORTAL W, V44, P46
  • [7] CHECK JH, 1989, J REPROD MED, V34, P218
  • [8] THE PIPELLE - A DISPOSABLE DEVICE FOR ENDOMETRIAL BIOPSY
    CORNIER, E
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 148 (01) : 109 - 110
  • [9] DANIEL AG, 1988, OBSTET GYNECOL, V71, P612
  • [10] GOLDSTEIN SR, 1988, OBSTET GYNECOL, V72, P200