Diffusion Tensor Imaging (DTI) of the Kidney at 3 Tesla-Feasibility, Protocol Evaluation and Comparison to 1.5 Tesla

被引:92
作者
Notohamiprodjo, Mike [1 ]
Dietrich, Olaf [2 ]
Horger, Wihelm [3 ]
Horng, Annie [1 ]
Helck, Andreas D. [1 ]
Herrmann, Karin A. [1 ]
Reiser, Maximilian F. [1 ]
Glaser, Christian [1 ]
机构
[1] Univ Hosp Munich, Dept Clin Radiol, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Hosp Munich, Dept Clin Radiol, Josef Lissner Lab Biomed Imaging, D-81377 Munich, Germany
[3] Siemens Healthcare Sector, Erlangen, Germany
关键词
diffusion tensor imaging; kidney; 3T; DTI; DWI; reproducibility; 3.0; T; MR; ANISOTROPY; COEFFICIENT; NOISE; REPRODUCIBILITY; STRATEGIES; SCHEMES; ABDOMEN; EXPERIENCE;
D O I
10.1097/RLI.0b013e3181d83abc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the feasibility of diffusion tensor imaging of the kidney at a field strength of 3T. We assessed fractional anisotropy (FA) and apparent diffusion coefficients (ADC) of various acquisition protocols and determined the reproducibility of these measurements. FA, ADC, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were compared with those acquired at 1.5T. Material and Methods: Ten healthy volunteers were examined with a respiratory-triggered echo-planar imaging sequence (TR: 1800 ms, TE: 58 ms, b = 0, 300 s/mm(2)) on a 3-Tesla whole-body MR scanner. Protocol variations included diffusion measurements during free-breathing, in 6 or 12 directions, and an additional b-value of 50 s/mm(2). A breath-hold protocol was also integrated (TR: 820 ms, TE: 58 ms, b = 0, 300 s/mm(2)). Measurements with 2 b-values and 6 diffusion directions were also acquired at 1.5 T. SNR was calculated with the difference-image method. Statistical analysis was performed with Wilcoxon signed-rank tests. Intrareader correlation was assessed with weighted kappa coefficients and reproducibility with the root-mean-square-average and the Bland-Altman-method. Results: At 3T, SNR of cortex and medulla and CNR of cortex/medulla were significantly higher than at 1.5T, leading to improved corticomedullary discrimination. There were no significant FA-and ADC differences with 2 b-values and 6 diffusion directions between measurements at 1.5T and 3T. FA of the medulla was significantly higher than that of the cortex in all measurements. Tractography visualized a typical radial diffusion direction in the medulla. Best image quality was achieved with a respiratory triggered protocol with 12 acquisition directions. Measurements with 3 b-values led to decreased ADCs. Acquisition in 12 directions resulted in decreased cortical FA. FA and ADC of breath-hold and free-breathing acquisitions were significantly higher than that of the respiratory-triggered protocol. Intrareader correlation ranged from kappa 0.60 to 0.96. Variance of the respiratory-triggered protocol was smaller than that of breath-hold and free-breathing protocols. Variance was highest for medullary FA in all protocols with reproducibility coefficients ranging from 0.36 to 0.46. Conclusion: Diffusion tensor imaging of the kidney at 3T is feasible and yields significantly higher SNR and CNR. FA and ADCs do not significantly differ from 1.5T. Number of b-values influences ADC-values. Acquisitions in 12 directions provide lower cortical FA-values. We recommend a respiratory-triggered protocol because of improved image quality and reproducibility.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 50 条
  • [41] Intraindividual Comparison of Image Quality in MR Urography at 1.5 and 3 Tesla in an Animal Model
    Regier, M.
    Nolte-Ernsting, C.
    Adam, G.
    Kemper, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (10): : 915 - 921
  • [42] Diffusion Tensor MRI of Brain in Healthy Adult Population: Normative Fractional Anisotropy Values at 3 Tesla MRI
    Mehta, Deepak Kumar, V
    Sharma, Dolly A.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (01) : TC5 - TC8
  • [43] Feasibility of In Vivo Quantitative Magnetic Resonance Imaging With Diffusion Weighted Imaging, T2-Weighted Relaxometry, and Diffusion Tensor Imaging in a Clinical 3 Tesla Magnetic Resonance Scanner for the Acute Traumatic Spinal Cord Injury of Rats Technical Note
    Mondragon-Lozano, Rodrigo
    Diaz-Ruiz, Araceli
    Rios, Camilo
    Olayo Gonzalez, Roberto
    Favila, Rafael
    Salgado-Ceballos, Hermelinda
    Roldan-Valadez, Ernesto
    SPINE, 2013, 38 (20) : E1242 - E1249
  • [44] Diagnostic utility of three Tesla diffusion tensor imaging in prostate cancer: correlation with Gleason score values
    Rasha Taha Abouelkheir
    Yasmin Ibrahim Aboshamia
    Saher Ebrahim Taman
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [45] 7 Tesla Diffusion Tensor Imaging Changes after Mindfulness-Based Cognitive Therapy for Depression
    Jakary, Angela
    Wen, Qiuting
    Gillung, Erin
    Holbrook, Natalie
    Eisendrath, Stuart
    Mukherjee, Pratik
    Nelson, Sarah
    Luks, Tracy
    BIOLOGICAL PSYCHIATRY, 2014, 75 (09) : 236S - 236S
  • [46] Assessment of Cervical Spondylotic Myelopathy Using Diffusion Tensor Magnetic Resonance Imaging Parameter at 3.0 Tesla
    Uda, Takehiro
    Takami, Toshihiro
    Tsuyuguchi, Naohiro
    Sakamoto, Shinichi
    Yamagata, Toru
    Ikeda, Hidetoshi
    Nagata, Takashi
    Ohata, Kenji
    SPINE, 2013, 38 (05) : 407 - 414
  • [47] Diagnostic utility of three Tesla diffusion tensor imaging in prostate cancer: correlation with Gleason score values
    Abouelkheir, Rasha Taha
    Aboshamia, Yasmin Ibrahim
    Taman, Saher Ebrahim
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [48] Impact of blood flow on diffusion coefficients of the human kidney: A time-resolved ECG-triggered diffusion-tensor imaging (DTI) study at 3T
    Heusch, Philipp
    Wittsack, Hans-Joerg
    Kroepil, Patric
    Blondin, Dirk
    Quentin, Michael
    Klasen, Janina
    Pentang, Gael
    Antoch, Gerald
    Lanzman, Rotem S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) : 233 - 236
  • [49] PERIPHERAL NERVE TRACTOGRAPHY IN SOFT TISSUE TUMORS: A PRELIMINARY 3-TESLA DIFFUSION TENSOR MAGNETIC RESONANCE IMAGING STUDY
    Kasprian, Gregor
    Amann, Gabriele
    Panotopoulos, Joannis
    Schmidt, Manfred
    Dominkus, Martin
    Trattnig, Siegfried
    Windhager, Reinhard
    Prayer, Daniela
    Noebauer-Huhmann, Iris
    MUSCLE & NERVE, 2015, 51 (03) : 338 - 345
  • [50] Diffusion Tensor Imaging of Healthy Skeletal Muscles A Comparison Between 7 T and 3 T
    Giraudo, Chiara
    Motyka, Stanislav
    Weber, Michael
    Feiweier, Thorsten
    Trattnig, Siegfried
    Bogner, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2019, 54 (01) : 48 - 54