Diffusion Tensor Imaging (DTI) of the Kidney at 3 Tesla-Feasibility, Protocol Evaluation and Comparison to 1.5 Tesla

被引:91
|
作者
Notohamiprodjo, Mike [1 ]
Dietrich, Olaf [2 ]
Horger, Wihelm [3 ]
Horng, Annie [1 ]
Helck, Andreas D. [1 ]
Herrmann, Karin A. [1 ]
Reiser, Maximilian F. [1 ]
Glaser, Christian [1 ]
机构
[1] Univ Hosp Munich, Dept Clin Radiol, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Hosp Munich, Dept Clin Radiol, Josef Lissner Lab Biomed Imaging, D-81377 Munich, Germany
[3] Siemens Healthcare Sector, Erlangen, Germany
关键词
diffusion tensor imaging; kidney; 3T; DTI; DWI; reproducibility; 3.0; T; MR; ANISOTROPY; COEFFICIENT; NOISE; REPRODUCIBILITY; STRATEGIES; SCHEMES; ABDOMEN; EXPERIENCE;
D O I
10.1097/RLI.0b013e3181d83abc
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate the feasibility of diffusion tensor imaging of the kidney at a field strength of 3T. We assessed fractional anisotropy (FA) and apparent diffusion coefficients (ADC) of various acquisition protocols and determined the reproducibility of these measurements. FA, ADC, signal-to-noise ratios (SNR), and contrast-to-noise ratios (CNR) were compared with those acquired at 1.5T. Material and Methods: Ten healthy volunteers were examined with a respiratory-triggered echo-planar imaging sequence (TR: 1800 ms, TE: 58 ms, b = 0, 300 s/mm(2)) on a 3-Tesla whole-body MR scanner. Protocol variations included diffusion measurements during free-breathing, in 6 or 12 directions, and an additional b-value of 50 s/mm(2). A breath-hold protocol was also integrated (TR: 820 ms, TE: 58 ms, b = 0, 300 s/mm(2)). Measurements with 2 b-values and 6 diffusion directions were also acquired at 1.5 T. SNR was calculated with the difference-image method. Statistical analysis was performed with Wilcoxon signed-rank tests. Intrareader correlation was assessed with weighted kappa coefficients and reproducibility with the root-mean-square-average and the Bland-Altman-method. Results: At 3T, SNR of cortex and medulla and CNR of cortex/medulla were significantly higher than at 1.5T, leading to improved corticomedullary discrimination. There were no significant FA-and ADC differences with 2 b-values and 6 diffusion directions between measurements at 1.5T and 3T. FA of the medulla was significantly higher than that of the cortex in all measurements. Tractography visualized a typical radial diffusion direction in the medulla. Best image quality was achieved with a respiratory triggered protocol with 12 acquisition directions. Measurements with 3 b-values led to decreased ADCs. Acquisition in 12 directions resulted in decreased cortical FA. FA and ADC of breath-hold and free-breathing acquisitions were significantly higher than that of the respiratory-triggered protocol. Intrareader correlation ranged from kappa 0.60 to 0.96. Variance of the respiratory-triggered protocol was smaller than that of breath-hold and free-breathing protocols. Variance was highest for medullary FA in all protocols with reproducibility coefficients ranging from 0.36 to 0.46. Conclusion: Diffusion tensor imaging of the kidney at 3T is feasible and yields significantly higher SNR and CNR. FA and ADCs do not significantly differ from 1.5T. Number of b-values influences ADC-values. Acquisitions in 12 directions provide lower cortical FA-values. We recommend a respiratory-triggered protocol because of improved image quality and reproducibility.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 50 条
  • [1] Diffusion Tensor Imaging (DTI) of the Normal Hum Uterus In Vivo at 3 Tesla: Comparison of DTI parameters in the Different Uterine Layers
    Fujimoto, Koji
    Kido, Aki
    Okada, Tomohisa
    Uchikoshi, Masato
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1494 - 1500
  • [2] Functional diffusion tensor imaging at 3 Tesla
    Mandl, Rene C. W.
    Schnack, Hugo G.
    Zwiers, Marcel P.
    Kahn, Rene S.
    Pol, Hilleke E. Hulshoff
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [3] Diffusion tensor imaging of the kidney at 3 Tesla MRI: normative values and repeatability of measurements in healthy volunteers
    Gurses, Bengi
    Kilickesmez, Ozgur
    Tasdelen, Neslihan
    Firat, Zeynep
    Gurmen, Nevzat
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (04) : 317 - 322
  • [4] Diffusion tensor imaging of prostate at 3.0 Tesla
    Li, Chunmei
    Chen, Min
    Li, Saying
    Zhao, Xuna
    Zhang, Chen
    Liu, Ming
    Zhou, Cheng
    ACTA RADIOLOGICA, 2011, 52 (07) : 813 - 817
  • [5] Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla
    Hilbert, Fabian
    Wech, Tobias
    Neubauer, Henning
    Veldhoen, Simon
    Bley, Thorsten Alexander
    Koestler, Herbert
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 193 - 201
  • [6] Diffusion tensor imaging of the anal canal at 3 tesla: Feasibility and reproducibility of anisotropy measures
    Goh, Vicky
    Tam, Emily
    Taylor, N. Jane
    Stirling, J. James
    Simcock, Ian C.
    Jones, Robert Glynne
    Padhani, Anwar R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (04) : 820 - 826
  • [7] Diffusion-weighted imaging of breast tumours at 3 Tesla and 7 Tesla: a comparison
    Gruber, S.
    Minarikova, L.
    Pinker, K.
    Zaric, O.
    Chmelik, M.
    Strasser, B.
    Baltzer, P.
    Helbich, T.
    Trattnig, S.
    Bogner, W.
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1466 - 1473
  • [8] Reproducibility Analysis of Diffusion Tensor Indices and Fiber Architecture of Human Calf Muscles In Vivo at 1.5 Tesla in Neutral and Plantarflexed Ankle Positions at Rest
    Sinha, Shantanu
    Sinha, Usha
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 107 - 119
  • [9] The Diffusion Tensor Imaging Properties of the Normal Testicles at 3 Tesla Magnetic Resonance Imaging
    Nissan, Noam
    Anaby, Debbie
    Tavor, Ido
    Kleinbaum, Yeruham
    Dotan, Zohar
    Konen, Eli
    Portnoy, Orith
    ACADEMIC RADIOLOGY, 2019, 26 (08) : 1010 - 1016
  • [10] Signal to Noise Ratio and Uncertainty in Diffusion Tensor Imaging at 1.5, 3.0, and 7.0 Tesla
    Polders, Daniel L.
    Leemans, Alexander
    Hendrikse, Jeroen
    Donahue, Manus J.
    Luijten, Peter R.
    Hoogduin, Johannes M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) : 1456 - 1463