Nonlinear Biomechanical Characteristics of the Schneiderian Membrane: Experimental Study and Numerical Modeling

被引:6
|
作者
Zhai, Min [1 ,2 ]
Cheng, Haode [1 ]
Yuan, Jing [1 ]
Wang, Xin [1 ]
Li, Bing [3 ]
Li, Dehua [1 ]
机构
[1] Fourth Mil Med Univ, Shaanxi Engn Res Ctr Dent Mat & Adv Manufacture, State Key Lab Mil Stomatol,Sch Stomatol, Natl Clin Res Ctr Oral Dis,Dept Oral Implants, Xian 710032, Shaanxi, Peoples R China
[2] Tibet Mil Area Command, Gen Hosp, Dept Stomatol, Lhasa 850007, Tibet, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710032, Shaanxi, Peoples R China
关键词
FINITE-ELEMENT-ANALYSIS; SINUS FLOOR ELEVATION; HUMAN PERIODONTAL-LIGAMENT; POSTERIOR MAXILLA; CLINICAL-IMPLICATIONS; RISK-FACTORS; AUGMENTATION; PERFORATION; THICKNESS; BEHAVIOR;
D O I
10.1155/2018/2829163
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. The aim of this study is to quantify the nonlinear mechanical behavior of the Schneiderian membrane. Methods. Thirty cadaveric maxillary sinus membrane specimens were divided into the elongation testing group and the perforation testing group. Mechanical experimental measurements were taken via ex vivo experiments. Theoretical curves were compared with experimental findings to assess the effectiveness of the nonlinear mechanical properties. The FE model with nonlinear mechanical properties was used to simulate the detachment of the Schneiderian membrane under loading. Results. The mean thickness of the membrane samples was 1.005 mm. The mean tensile strength obtained by testing was 6.81 N/mm(2). In membrane perforation testing, the mean tensile strength and the linear elastic modulus were significantly higher than those in membrane elongation testing (P < 0.05). The mean adhesion force between the Schneiderian membrane and the bone was 0.052 N/mm. By FE modeling, the squared correlation coefficients of theoretical stress-strain curves for the nonlinear and linear models were 0.99065 and 0.94656 compared with the experimental data. Conclusions. The biomechanical properties of the Schneiderian membrane were implemented into the FE model, which was applied to simulate the mechanical responses of the Schneiderian membrane in sinus floor elevation.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] An experimental and numerical study on the vibration characteristics of glass fiber composite sandwich panel with lattice cores
    Eratbeni, Mehdi Gholizadeh
    Rostamiyan, Yasser
    Seyyedi, Seyyed Masoud
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2022, 236 (08) : 1604 - 1613
  • [32] Influences of Schneiderian membrane conditions on the early outcomes of osteotome sinus floor elevation technique: a prospective cohort study in the healing period
    Qin, Lei
    Lin, Sheng-xiao
    Guo, Zheng-Ze
    Zhao, Ningbo
    Song, Ying-Liang
    Xie, Chao
    Li, De-Hua
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1074 - 1081
  • [33] The influence of suturing and or gluing of perforated Schneiderian membrane during sinuslift procedure on the outcome: a retrospective study
    Khoury, Fouad
    Schmidt, Christoph
    Jackowski, Jochen
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [34] Study of Elevation Forces and Resilience of the Schneiderian Membrane Using a New Balloon Device in Maxillary Sinus Elevations on Pig Head Cadavers
    Fernandez Castellano, Erick Rafael
    Marquez Sanchez, Magaly Teresa
    Flores Fraile, Javier
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [35] Numerical and Experimental Study on Convective Heat Transfer Characteristics in Foam Materials
    Lu, Hongyan
    Yang, Lixin
    Wu, Zhiyong
    Xu, Siqi
    ENERGIES, 2020, 13 (02)
  • [36] Experimental and numerical study of the hydrodynamic characteristics of a semisubmersible aquaculture facility in waves
    Liu, Hang-Fei
    Bi, Chun-Wei
    Zhao, Yun-Peng
    OCEAN ENGINEERING, 2020, 214 (214)
  • [37] Experimental and numerical study on the flow characteristics of slug flow in a horizontal elbow
    Cao, Xuewen
    Zhang, Pan
    Li, Xiang
    Li, Zheng
    Zhang, Qianrong
    Bian, Jiang
    JOURNAL OF PIPELINE SCIENCE AND ENGINEERING, 2022, 2 (04):
  • [38] Experimental and Numerical Study on the Nonlinear Behavior of Strengthened Beams Under High Preload
    Zhao, Jingxian
    Liu, Hongbo
    Chen, Zhihua
    Zhang, Shishuo
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (05) : 1564 - 1587
  • [39] Experimental and Numerical Study on the Nonlinear Behavior of Strengthened Beams Under High Preload
    Jingxian Zhao
    Hongbo Liu
    Zhihua Chen
    Shishuo Zhang
    International Journal of Steel Structures, 2021, 21 : 1564 - 1587
  • [40] Experimental Determination of Corneal Elastic Constants and Their Use in Biomechanical Modeling
    Munoz-Villaescusa, Claudia
    Nunez-Chongo, Osiris de la C.
    Cardenas-Diaz, Taimi
    Batista-Leyva, Alfo J.
    Cavas-Martinez, Francisco
    APPLIED SCIENCES-BASEL, 2021, 11 (23):