Nonlinear Biomechanical Characteristics of the Schneiderian Membrane: Experimental Study and Numerical Modeling

被引:6
|
作者
Zhai, Min [1 ,2 ]
Cheng, Haode [1 ]
Yuan, Jing [1 ]
Wang, Xin [1 ]
Li, Bing [3 ]
Li, Dehua [1 ]
机构
[1] Fourth Mil Med Univ, Shaanxi Engn Res Ctr Dent Mat & Adv Manufacture, State Key Lab Mil Stomatol,Sch Stomatol, Natl Clin Res Ctr Oral Dis,Dept Oral Implants, Xian 710032, Shaanxi, Peoples R China
[2] Tibet Mil Area Command, Gen Hosp, Dept Stomatol, Lhasa 850007, Tibet, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710032, Shaanxi, Peoples R China
关键词
FINITE-ELEMENT-ANALYSIS; SINUS FLOOR ELEVATION; HUMAN PERIODONTAL-LIGAMENT; POSTERIOR MAXILLA; CLINICAL-IMPLICATIONS; RISK-FACTORS; AUGMENTATION; PERFORATION; THICKNESS; BEHAVIOR;
D O I
10.1155/2018/2829163
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. The aim of this study is to quantify the nonlinear mechanical behavior of the Schneiderian membrane. Methods. Thirty cadaveric maxillary sinus membrane specimens were divided into the elongation testing group and the perforation testing group. Mechanical experimental measurements were taken via ex vivo experiments. Theoretical curves were compared with experimental findings to assess the effectiveness of the nonlinear mechanical properties. The FE model with nonlinear mechanical properties was used to simulate the detachment of the Schneiderian membrane under loading. Results. The mean thickness of the membrane samples was 1.005 mm. The mean tensile strength obtained by testing was 6.81 N/mm(2). In membrane perforation testing, the mean tensile strength and the linear elastic modulus were significantly higher than those in membrane elongation testing (P < 0.05). The mean adhesion force between the Schneiderian membrane and the bone was 0.052 N/mm. By FE modeling, the squared correlation coefficients of theoretical stress-strain curves for the nonlinear and linear models were 0.99065 and 0.94656 compared with the experimental data. Conclusions. The biomechanical properties of the Schneiderian membrane were implemented into the FE model, which was applied to simulate the mechanical responses of the Schneiderian membrane in sinus floor elevation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Schneiderian Membrane Collateral Damage Caused by Collagenated and Non-Collagenated Xenografts: A Histological Study in Rabbits
    Nakajima, Yasushi
    Botticelli, Daniele
    De Rossi, Ermenegildo Federico
    Balan, Vitor Ferreira
    Godoy, Eduardo Pires
    Silva, Erick Ricardo
    Xavier, Samuel Porfirio
    DENTISTRY JOURNAL, 2023, 11 (02)
  • [22] Transient swelling of the Schneiderian membrane after transversal sinus augmentation: a pilot study
    Quirynen, Marc
    Lefever, David
    Hellings, Peter
    Jacobs, Reinhilde
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (01) : 36 - 41
  • [23] Schneiderian membrane perforation via transcrestal sinus floor elevation: A randomized ex vivo study with endoscopic validation
    Gargallo-Albiol, Jordi
    Tattan, Mustafa
    Sinjab, Khaled H.
    Chan, Hsun-Liang
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (01) : 11 - 19
  • [24] An Experimental Study and Modeling of Loading and Unloading of Nonlinear Viscoelastic Contacts
    Tsai, Chia-Hung Dylan
    Kao, Linin
    Yoshimoto, Kayo
    Higashimori, Mitsuru
    Kaneko, Makoto
    2009 IEEE-RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2009, : 3404 - 3409
  • [25] Volume stability of the augmented sinus using a collagenated bovine bone mineral grafted in case of a perforated Schneiderian membrane: An experimental study in rabbits
    Paik, Jeong-Won
    Cha, Jae-Kook
    Paeng, Kyeong-Won
    Kim, Myong-Ji
    Thoma, Daniel S.
    Jung, Ronald E.
    Jung, Ui-Won
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2020, 47 (05) : 649 - 656
  • [26] Experimental Dynamic Testing and Numerical Modeling of Historical Belfry
    Nistico, N.
    Gambarelli, S.
    Fascetti, A.
    Quaranta, G.
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2016, 10 (04) : 476 - 485
  • [27] A Numerical and Experimental Study of Adhesively-Bonded Polyethylene Pipelines
    Guilpin, Antoine
    Franciere, Geoffrey
    Barton, Lewis
    Blacklock, Matthew
    Birkett, Martin
    POLYMERS, 2019, 11 (09)
  • [28] Experimental and numerical study on nonlinear mechanical properties of laminated woven fabrics
    Qiu, Zhenyu
    Chen, Wujun
    Gao, Chengjun
    Hu, Yu
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 164 : 672 - 681
  • [29] A numerical and experimental study of the quasi-static deployment of membrane tubes
    Bbuzidi, Rabah
    Buytet, Saridrine
    Le van, Anh
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2013, 50 (05) : 651 - 661
  • [30] Experimental and numerical analysis of electroactive characteristics of scleral tissue
    Mehr, Jafar Arash
    Hatami-Marbini, Hamed
    ACTA BIOMATERIALIA, 2022, 143 : 127 - 137