A robust and rapid liquid chromatography tandem mass spectrometric method for the quantitative analysis of 5-azacytidine

被引:11
|
作者
Anders, Nicole M. [1 ]
Wanjiku, Teresia M. [1 ]
He, Ping [1 ]
Azad, Nilofer S. [1 ]
Rudek, Michelle A. [1 ]
机构
[1] Johns Hopkins Univ, Sidney Kimmel Comprehens Canc Ctr, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
5-azacytidine; DNA methyltransferase inhibitor; LC; MS; pharmacokinetics; HEMATOLOGIC MALIGNANCIES; CYTIDINE DEAMINASE; AZACITIDINE; PHARMACOKINETICS; DEGRADATION;
D O I
10.1002/bmc.3562
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The DNA methyltransferase inhibitor 5-azacytidine is being evaluated clinically as an oral formulation to treat various solid tumors. A sensitive, reliable method was developed to quantitate 5-azacytidine using LC-MS/MS to perform detailed pharmacokinetic studies. The drug of interest was extracted from plasma using Oasis MCX ion exchange solid-phase extraction 96-well plates. Chromatographic separation was achieved with a YMC J'sphere M80 C-18 column and isocratic elution with a methanol-water-formic acid (15:85:0.1, v/v/v) mobile phase over a 7 min total analytical run time. An AB Sciex 5500 triple quadrupole mass spectrometer operated in positive electrospray ionization mode was used for the detection of 5-azacytidine. The assay range was 5-500 ng/mL and proved to be accurate (97.8-109.1%) and precise (CV 9.8%). Tetrahydrouridine was used to stabilize 5-azacytidine in blood/plasma samples. With the addition of tetrahydrouridine, long-term frozen plasma stability for 5-azacytidine at -70 degrees C has been determined for at least 323 days. The method was applied for the measurement of total plasma concentrations of 5-azacytidine in a cancer patient receiving a 300 mg oral daily dose. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:494 / 496
页数:3
相关论文
共 50 条
  • [41] Quantitative liquid chromatography-tandem mass spectrometric analysis of 11-dehydro TXB2 in urine
    Suzuki, N
    Hishinuma, T
    Chiba, A
    Saga, T
    Tsukamoto, H
    Mizugaki, M
    Goto, J
    PROSTAGLANDINS & OTHER LIPID MEDIATORS, 2004, 73 (1-2) : 103 - 110
  • [42] Rapid liquid chromatographic - Tandem mass spectrometric method for the quantification of pentoxifylline in human plasma
    Ramakrishna, NVS
    Vishwottaml, KN
    Manoj, S
    Koteshwara, M
    Santosh, M
    Anjaneyulu, Y
    CHROMATOGRAPHIA, 2006, 63 (3-4) : 135 - 141
  • [43] Rapid scanning technique for the determination of optimal tandem mass spectrometric conditions for quantitative analysis
    Hiller, DL
    Zuzel, TJ
    Williams, JA
    Cole, RO
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (06) : 593 - 597
  • [44] Rapid scanning technique for the determination of optimal tandem mass spectrometric conditions for quantitative analysis
    Precandidate Technology, Pfizer Inc., Eastern Point Road, Groton, CT 06340, United States
    RAPID COMMUN. MASS SPECTROM., 6 (593-597):
  • [45] Development of a qualitative liquid chromatography/tandem mass spectrometric method for the detection of narcotics in urine relevant to doping analysis
    Deventer, Koen
    Pozo, Oscar J.
    Van Eenoo, Peter
    Delbeke, Frans T.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) : 3015 - 3023
  • [46] Liquid chromatography/tandem mass spectrometric analysis of penicillamine for its pharmacokinetic evaluation in dogs
    Lehner, Andreas F.
    Dirikolu, Levent
    Johnson, Margaret
    Buchweitz, John P.
    Langlois, Daniel K.
    TOXICOLOGY MECHANISMS AND METHODS, 2020, 30 (09) : 687 - 702
  • [47] Analysis of coumarin in various foods using liquid chromatography with tandem mass spectrometric detection
    Marion Raters
    Reinhard Matissek
    European Food Research and Technology, 2008, 227 : 637 - 642
  • [48] A rapid and sensitive liquid chromatography–tandem mass spectrometric method for the determination of hederasaponin B in rat plasma: Application to a pharmacokinetic study
    Jiaxin Liu
    Xueyan Yang
    Lin Li
    Qili Zhang
    Zhaoyan Zhang
    Xin Zhang
    Yunli Zhao
    Miao Yu
    Zhiguo Yu
    Asian Journal of Pharmaceutical Sciences, 2017, 12 (04) : 363 - 369
  • [49] Analysis of coumarin in various foods using liquid chromatography with tandem mass spectrometric detection
    Raters, Marion
    Matissek, Reinhard
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 227 (02) : 637 - 642
  • [50] Validation of a rapid liquid chromatography-tandem mass spectrometric assay for the determination of octreotide plasma concentrations
    Capron, Arnaud
    Destree, Jennifer
    Maiter, Dominique
    Wallemacq, Pierre
    CLINICAL BIOCHEMISTRY, 2014, 47 (1-2) : 139 - 141