Novel multi-gas chromatography-olfactometry device and software for the identification of odour-active compounds

被引:35
作者
Berdague, J. L. [1 ]
Tournayre, P. [1 ]
Cambou, S. [1 ]
机构
[1] INRA, UR370 QuaPA, Equpe Typ Aromat & Authent, F-63122 St Genes Champanelle, France
关键词
gas chromatography; olfactometry; sniffling; data processing;
D O I
10.1016/j.chroma.2006.12.102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this work was to devise a novel fully computerised chromatography-olfactometry system where eight sniffers detect volatile compounds obtained from a single chromatographic separation. The technical options taken to implement this system are described in detail. The new methods and software developed and applied to analyse data obtained by gas chromatography-olfactometry and mass spectrometry (GC-O/MS) are presented. We found that 46 odorous zones could be detected by a panel of eight sniffers during the 35 min of the analysis of the volatile compounds extracted from a cheese by purge-and-trap. Synchronisation of olfactometry and mass spectrometry data enabled us to propose 44 structures to account for 44 out of these 46 odorous zones. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 17 条
[1]   ANALYSIS OF ODOR-ACTIVE VOLATILES IN CHEDDAR CHEESE HEADSPACE BY MULTIDIMENSIONAL GC/MS SNIFFING [J].
ARORA, G ;
CORMIER, F ;
LEE, B .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (03) :748-752
[2]   Multidimensional gas chromatography using a double cool-strand interface [J].
Begnaud, F ;
Chaintreau, A .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :13-20
[3]  
Berdagué JL, 2003, Flavour Research at the Dawn of the Twenty-First Century, P514
[4]  
BERDAGUE JL, 2000, Patent No. 001210006
[5]  
BERDAGUE JL, 2004, Patent No. 0350257
[6]  
Berodier F, 1997, FOOD SCI TECHNOL-LEB, V30, P653, DOI 10.1006/fstl.1996.0235
[7]   Effect of a dry purge step on the analysis by dynamic headspace -: GC-MS of the volatile fraction of a cheese [J].
Canac-Arteaga, D ;
Viallon, C ;
Berdagué, JL .
ANALUSIS, 1999, 27 (09) :780-785
[8]   Improved hardware and software for quick gas chromatography-olfactometry using CHARM and GC-"SNIF" analysis [J].
Debonneville, C ;
Orsier, B ;
Flament, I ;
Chaintreau, A .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2345-2351
[9]   Quantitative gas chromatography-olfactometry. Analytical characteristics of a panel of judges using a simple quantitative scale as gas chromatography detector [J].
Ferreira, V ;
Pet'ka, J ;
Aznar, M ;
Cacho, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) :169-178
[10]   Possible influence of breathing on detection frequency and intensity rating in gas chromatography-olfactometry [J].
Hanaoka, K ;
Vallet, N ;
Giampaoli, P ;
Heyd, B ;
MacLeod, P .
FOOD CHEMISTRY, 2001, 72 (01) :97-103