Morphometric trajectory analysis for the C2 crossing laminar screw technique

被引:9
作者
Yue, Bin [1 ,2 ]
Kwak, Dai-Soon [1 ]
Kim, Moon-Kyu [3 ]
Kwon, Seong-Oh [4 ]
Han, Seung-Ho [1 ]
机构
[1] Catholic Univ Korea, Dept Anat, Coll Med, Catholic Inst Appl Anat, Seoul 137701, South Korea
[2] Qingdao Univ, Coll Med, Dept Spine Surg, Affiliated Hosp, Qingdao 266071, Peoples R China
[3] Hallym Univ, Coll Med, Dept Neurosurg, Kangdong Sacred Heart Hosp, Hallym, South Korea
[4] CHA Univ, Dept Neurosurg, CHA Gumi Med Ctr, Pochon, South Korea
基金
新加坡国家研究基金会;
关键词
Cervical vertebra; Crossing laminar screw; Trajectory analysis; Laminar thickness; Entry point; Safe angle; TRANSARTICULAR SCREWS; ATLANTOAXIAL FIXATION; INTRALAMINAR SCREW; VERTEBRAL ARTERY; CERVICAL-SPINE; PLACEMENT; PEDICLE; OCCLUSION; PATIENT; AXIS;
D O I
10.1007/s00586-010-1331-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This paper reports a morphometric study of the C2 laminae to provide quantitative anatomical data for safe crossing laminar screw placement. A valid trajectory is essential for C2 crossing laminar screw placement. Although several clinical technique notes and modifications to define a safe screw trajectory have been introduced in the recent years, no morphometric analysis has been performed to confirm the accuracy of screw trajectory using this technique. In this study, morphometric analysis was performed on 100 Korean C2 three-dimensional reconstruction CT images. The reconstructive C2 vertebrae from the post-edge of the spinal canal to the spinal process were divided into several zones, 1 mm each. Each zone was chosen as the entry point to imitate a crossing laminar screw (3.5 mm diameter) placement. In each 1-mm zoned trajectory, the screw pass ratio (PR), safe screw angle range (SAR) and maximum screw length (MSL) were measured and compared with the data from the other zoned trajectories. The zone '5-6 mm posterior to the post-edge of the spinal canal' was found to be a more feasible and safer entry point for guiding a crossing laminar screw placement than the other zones because this zone could provide a trajectory with maximal PR (85%), SAR (9.57 +/- A 4.36A(0)) and a larger MSL (21.74 +/- A 2.44 mm) than the other areas. The recommended safe screw angle in the axial plane is 49.68 +/- A 4.94 to 59.19 +/- A 4.70A(0). However, the screw angle can vary considerably according to the individual variance. A preoperative evaluation of the screw trajectory is essential for safe screw placement using this technique.
引用
收藏
页码:828 / 832
页数:5
相关论文
共 24 条
  • [1] Anatomic considerations for the placement of C2 laminar screws
    Cassinelli, Ezequiel H.
    Lee, Michael
    Skalak, Anthony
    Ahn, Nicholas U.
    Wright, Neill M.
    [J]. SPINE, 2006, 31 (24) : 2767 - 2771
  • [2] Anatomic consideration of C2 pedicle screw placement
    Ebraheim, N
    Rollins, JR
    Xu, RM
    Jackson, WT
    [J]. SPINE, 1996, 21 (06) : 691 - 694
  • [3] Constructs incorporating intralaminar C2 screws provide rigid stability for Atlantoaxial fixation
    Gorek, J
    Acaroglu, E
    Berven, S
    Yousef, A
    Puttlitz, CM
    [J]. SPINE, 2005, 30 (13) : 1513 - 1518
  • [4] Significance of laminar screw fixation in the subaxial cervical spine
    Hong, Jae Taek
    Sung, Jae Hoon
    Son, Byung Chul
    Lee, Sang Won
    Park, Chun Kun
    [J]. SPINE, 2008, 33 (16) : 1739 - 1743
  • [5] Hu Yong, 2008, Zhongguo Gu Shang, V21, P581
  • [6] Anatomic study of the axis for surgical planning of transarticular screw fixation
    Igarashi, T
    Kikuchi, S
    Sato, K
    Kayama, S
    Otani, K
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (408) : 162 - 166
  • [7] Modification of Wright's technique for placement of bilateral crossing C2 translaminar screws: technical note
    Jea, Andrew
    Sheth, Rishi N.
    Vanni, Steve
    Green, Barth A.
    Levi, Allan D.
    [J]. SPINE JOURNAL, 2008, 8 (04) : 656 - 660
  • [8] PRIMARY POSTERIOR FUSION-C1/2 IN ODONTOID FRACTURES - INDICATIONS, TECHNIQUE, AND RESULTS OF TRANSARTICULAR SCREW FIXATION
    JEANNERET, B
    MAGERL, F
    [J]. JOURNAL OF SPINAL DISORDERS, 1992, 5 (04): : 464 - 475
  • [9] Modification of Wright's technique for C2 translaminar screw fixation: technical note
    Kabir, S. M. R.
    Casey, A. T. H.
    [J]. ACTA NEUROCHIRURGICA, 2009, 151 (11) : 1543 - 1547
  • [10] Computerized tomographic measurements of morphometric parameters of the C2 for the feasibility of laminar screw fixation in Korean population
    Kim, Young-June
    Rhee, Woo Tack
    Lee, Sang-Bok
    You, Seung-Hoon
    Lee, Sang-Youl
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2008, 44 (01) : 15 - 18