A Highly Sensitive Electrochemical Sensor System to Detect and Distinguish Between Glyphosate and Glufosinate

被引:15
作者
Dhamu, Vikram Narayanan [1 ]
Poudyal, Durgasha C. [1 ]
Muthukumar, Sriram [2 ]
Prasad, Shalini [1 ,2 ]
机构
[1] Univ Texas Dallas, Dept Bioengn, Richardson, TX 75080 USA
[2] EnLiSense LLC, Allen, TX 75013 USA
关键词
Sensors; Bioelectrochemistry; Field deployable platform; Affinity biosensing; Selective detection; Food quality evaluation; Glyphosate pesticide detection; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; RAPID-DETERMINATION; GAS-CHROMATOGRAPHY; ACID RESIDUES; WATER; HERBICIDES; BIOSENSOR; IMPEDANCE; SAMPLES;
D O I
10.1149/1945-7111/ac00f7
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Glyphosate and Glufosinate are widely used herbicides worldwide for controlling weeds in the agriculture field. The large increase in the herbicides tolerant plants has dramatically affected the level of usage of these herbicides recently. With the growing alarm about the associated toxicity to the environmental and human health, there is a need for direct low concentration detection of these herbicides present at the various food crops products and water. In this work, we present a simple electrochemical sensor to selectively detect glyphosate in presence of Glufosinate a structurally similar phosphorus containing amino acid group. The sensor substrate is made up of an interdigitated Au microelectrode, which was immobilized with glyphosate antibody, bounded with the help of the Dithiobis (succinimidyl propionate) (DSP) crosslinker. The data obtained using non-faradaic EIS method, showed a linear range across the whole dosing interval-10 ng ml(-1) to 50 ug ml(-1) for glyphosate in presence of the interfering component Glufosinate with the detection limit of 10 ng ml(-1) and the sensitivity of 1.323% (change in impedance)/ppb. Further the sensor has been proven to measure the spiked pesticides doses in real oatmeal samples. Such micro-volume, high-sensitive, and selective platform which requires no prior sample preparation can be a potentially game-changing electrochemical on-field sensing device to measure the threshold limit, a precautionary step to alert the common man using the food products and farmers working in the agriculture field.
引用
收藏
页数:7
相关论文
共 48 条
  • [1] Abcam K.D., VALUE QUANTITATIVE M
  • [2] Review of the existing maximum residue levels for glyphosate according to Article 12 of Regulation (EC) No 396/2005 - revised version to take into account omitted data
    Anastassiadou, Maria
    Brancato, Alba
    Cabrera, Luis Carrasco
    Ferreira, Lucien
    Greco, Luna
    Larrah, Samira
    Kazocina, Aija
    Leuschner, Renata
    Magrans, Jose Oriol
    Miron, Ileana
    Nave, Stefanie
    Pedersen, Ragnor
    Reich, Hermine
    Rojas, Alejandro
    Sacchi, Angela
    Santos, Miguel
    Stanek, Alois
    Theobald, Anne
    Vagenende, Benedicte
    Verani, Alessia
    [J]. EFSA JOURNAL, 2019, 17 (10)
  • [3] Glyphosate Determination by Coupling an Immuno-Magnetic Assay with Electrochemical Sensors
    Bettazzi, Francesca
    Natale, Aline Romero
    Torres, Eduardo
    Palchetti, Ilaria
    [J]. SENSORS, 2018, 18 (09)
  • [4] Electrochemical Biosensor for Sensitive Quantification of Glyphosate in Maize Kernels
    Cahuantzi-Munoz, Selene L.
    Gonzalez-Fuentes, Miguel A.
    Ortiz-Frade, Luis A.
    Torres, Eduardo
    Talu, Stefan
    Trejo, G.
    Mendez-Albores, Alia
    [J]. ELECTROANALYSIS, 2019, 31 (05) : 927 - 935
  • [5] DOUBLE-LAYER EFFECT CORRECTION IN CHRONOAMPEROMETRY WITH LINEAR POTENTIAL SWEEP
    CASELLI, M
    OTTOMBRI.G
    PAPOFF, P
    [J]. ELECTROCHIMICA ACTA, 1968, 13 (02) : 241 - &
  • [6] A Simple and Efficient Method for Derivatization of Glyphosate and AMPA Using 9-Fluorenylmethyl Chloroformate and Spectrophotometric Analysis
    Catrinck, Tereza C. P. G.
    Dias, Amanda
    Aguiar, Maria Clara S.
    Silverio, Flaviano O.
    Fidencio, Paulo H.
    Pinho, Gevany P.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (07) : 1194 - 1199
  • [7] Development of a flexible, sweat-based neuropeptide Y detection platform
    Churcher, Nathan Kodjo Mintah
    Upasham, Sayali
    Rice, Paul
    Bhadsavle, Serena
    Prasad, Shalini
    [J]. RSC ADVANCES, 2020, 10 (39) : 23173 - 23186
  • [8] Simulated impedance of diffusion in porous media
    Cooper, Samuel J.
    Bertei, Antonio
    Finegan, Donal P.
    Brandon, Nigel P.
    [J]. ELECTROCHIMICA ACTA, 2017, 251 : 681 - 689
  • [9] ElectrochemSENSE: A platform towards field deployable direct on-produce glyphosate detection
    Dhamu, Vikram Narayanan
    Prasad, Shalini
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [10] Dorledo de Faria R.A., 2019, INT J BIOSENS BIOELE, V5, P29, DOI [10.15406/ijbsbe.2019.05.00148, DOI 10.15406/IJBSBE.2019.05.00148]